Local Guide · Plumbing
Does My Restaurant Need a Grease Trap? Rules, Pumping, the 25% Rule and Fines in Texas and Florida
A plain-English compliance guide for restaurant owners, landlords and property managers: when the plumbing code requires a grease trap or interceptor, how often it must be pumped, what the 25% rule means, which records to keep, and what local programs in San Antonio, Austin, Tampa and Orlando expect.
Yes, almost every commercial kitchen needs one. The plumbing codes used in Texas and Florida require a grease interceptor or automatic grease removal device for kitchen fixtures in restaurants and other food service. Local sewer utilities then set pumping rules. Many use a 25% rule: pump when grease and solids fill a quarter of the unit's depth or volume. San Antonio also sets a 90-day minimum. Florida law requires a signed service manifest for every pump-out, and both states ban returning pumped grease to the trap.
Key facts
- Florida Building Code, Plumbing 8th Edition (2023) section 1003.3.1 requires a grease interceptor or automatic grease removal device for drainage from fixtures in food preparation areas such as restaurants, hotel kitchens and hospitals.
- FBC Plumbing 1003.3.2: a food waste disposer may not discharge to a grease interceptor; 1003.3.4: interceptors are not required for individual dwelling units.
- FBC Plumbing 1003.3.7: a gravity grease interceptor is sized by multiplying peak drain flow in gallons per minute by a 30-minute retention time.
- Fla. Stat. 403.0741 bans haulers from returning grease waste or graywater to a trap and requires a signed service manifest, kept on site by the restaurant for 1 year.
- Florida fines under 403.0741: up to $100 per manifest failure, up to $250 per failure to clean a trap, and at least $2,500 for unlawful disposal.
- San Antonio Water System's grease procedure manual sets a 90-day minimum interceptor maintenance interval, or sooner when waste reaches 25% of wetted depth.
- SAWS requires every food service interceptor to be inspected at least once per calendar year by a licensed plumber or SAWS-approved professional, with defects fixed within 90 days.
- Texas rule 30 TAC 312.142 requires anyone transporting grease trap waste to hold a TCEQ registration, renewed every two years.
- Under 30 TAC 312.145, a Texas transporter must return a trip ticket copy to the generator within 15 days after disposal and keep trip tickets for five years.
- Tampa requires grease traps to be inspected, cleaned and maintained at least weekly and cleaned when captured material exceeds 25% of total volume.
Grease trap vs grease interceptor: what's the difference?
People use the words loosely, and many local rules use both. The plumbing code draws the line by how the device works, not by its name.
- Hydromechanical grease interceptor (what most people call a grease trap): a smaller box, often under a sink or in the floor, that uses baffles and a flow-control device to slow water so grease floats and is held. It is rated by flow in gallons per minute and grease capacity in pounds.
- Gravity grease interceptor: a large in-ground tank, usually concrete, plastic or fiberglass, often 750 gallons or more, that relies on retention time. Wastewater sits long enough for grease to float and solids to sink.
- Automatic grease removal device (AGRD): a powered unit that skims grease out on a timer into a container your staff empties.
The City of Tampa's rules show how local programs use the terms: they set a weekly inspection and cleaning duty for "grease traps" and separate pumping triggers for "interceptors." When you read your city's ordinance, check how it defines each term, because the cleaning schedule usually follows the definition.
| Feature | Hydromechanical (trap) | Gravity interceptor |
|---|---|---|
| Typical location | Under sink or in kitchen floor | Outside, in the ground |
| Sizing basis | Flow rate (gpm) and grease capacity (lb) | Peak flow times 30 minutes of retention (FBC 1003.3.7) |
| Standard | ASME A112.14.3, A112.14.4, CSA B481 or PDI G101 | IAPMO/ANSI Z1001 |
| Who usually cleans | Staff (where local rules allow) or a hauler | A registered or permitted hauler with a pump truck |
| Typical cleaning interval | Weekly in Tampa; weekly for 100 gallons or less in SAWS guidance | When the 25% trigger is reached; 90-day minimum in San Antonio |
Does my restaurant need a grease trap?
If you cook or wash dishes commercially, assume yes. Florida's plumbing code, the 2023 Florida Building Code, Plumbing (8th Edition), based on the 2021 International Plumbing Code, says a grease interceptor or automatic grease removal device is required to receive drainage from fixtures in food preparation areas, such as restaurants, hotel kitchens and hospitals. The listed fixtures include pot sinks, prerinse sinks and wok stations. Dallas and San Antonio use the International Plumbing Code with local amendments, so the same section numbers apply there. Houston and Austin use the Uniform Plumbing Code, which has its own interceptor chapter, so confirm the section with the city's plumbing reviewer.
On top of the plumbing code, sewer utilities have their own fats, oils and grease (FOG) programs. San Antonio Water System (SAWS) says restaurants and other commercial food preparation companies are required by city ordinance to use grease traps, and its program applies to all food service and food processing establishments in the city limits and extraterritorial jurisdiction. Orlando asks food service establishments, and other businesses that discharge FOG such as car washes and mechanic shops, to register with its Grease Management Program.
Who else may need one
- Cafeterias in schools, offices, hospitals and nursing homes
- Hotels, caterers, churches with commercial kitchens
- Bakeries, delis, coffee shops that wash dishes, grocery stores with butcher or deli counters
- Commissary kitchens used by food trucks
- Food processing plants
The code does not require an interceptor for individual dwelling units or private living quarters (FBC 1003.3.4). For a small kitchen that only reheats packaged food, ask your local program in writing whether an exemption applies, because some programs grant variances and others do not.
How do I size a grease interceptor?
Sizing is a design job for a licensed plumber or engineer and must be approved by the local plumbing official (FBC 1003.2). Knowing the method helps you check a bid and avoid buying a unit the city will reject.
Hydromechanical interceptors
FBC 1003.3.5 says these units are sized under ASME A112.14.3, A112.14.4, A112.14.6, CSA B481.3 or PDI G101. The code ties grease retention capacity to the flow rating. Examples from Table 1003.3.5.1:
| Flow-through rating | Minimum grease retention |
|---|---|
| 4 gpm | 8 lb |
| 10 gpm | 20 lb |
| 25 gpm | 50 lb |
| 100 gpm | 200 lb |
Above 100 gpm, the required retention in pounds is double the flow rating. A flow-control device must be vented and end at least 6 inches above the sink's flood rim, or as the manufacturer instructs (FBC 1003.3.5.2).
Gravity interceptors
FBC 1003.3.7 sizes a gravity interceptor by multiplying the peak drain flow into it, in gallons per minute, by a retention time of 30 minutes. A kitchen whose fixtures can send 50 gpm at peak would need at least a 1,500-gallon interceptor under that method. Gravity units are designed and tested to IAPMO/ANSI Z1001.
Local formulas
Some cities publish their own worksheets. Tampa's calculator uses two formulas:
- Restaurants: seats x gallons per seat x (hours open / 12) x loading factor. Use 25 gallons per seat with regular dishware or a dishwasher, or 10 with paper and baskets and no dishwasher. Loading factors run from 0.75 to 2.00 based on location, such as an interstate highway site at 2.00.
- Other commercial kitchens: meals per day x 5 gallons per meal x a loading factor of 1.00 with a dishwasher or 0.75 without.
For example, a 60-seat Tampa restaurant on a main highway using real dishes and open 12 hours would come out to 60 x 25 x 1 x 1.00 = 1,500 gallons under that worksheet. Tampa says the calculator is a reference only and that actual sizing follows Chapter 10 of the Florida Building Code.
Florida adds one wrinkle: an interceptor serving a building on a septic system is sized and approved under the onsite sewage rule (Rule 64E-6, F.A.C.), not Section 1003.3.5 (FBC 1003.3.9).
Two design rules that cause failed inspections
- Do not route a food waste disposer into a grease interceptor (FBC 1003.3.2). Ground food fills the unit with solids.
- Do not send toilets or other sanitary waste through it. The code bars sending waste that needs no separation into an interceptor (FBC 1003.2).
What is the 25% rule for grease traps?
The 25% rule says a trap or interceptor must be cleaned before grease and solids take up a quarter of its capacity. Past that point, grease starts escaping out the outlet into the sewer. The exact wording differs by city, which matters during an inspection:
| Jurisdiction | How the 25% is measured | Other triggers |
|---|---|---|
| San Antonio (SAWS) | Floatable and settled waste reaching 25% of wetted depth, measured from the static water level to the tank bottom | 90-day minimum maintenance interval; an inspection finding 25% or more of wetted height is a violation |
| Tampa (traps) | Captured material displacing more than 25% of total volume | Inspect, clean and maintain at least weekly |
| Tampa (interceptors) | Grease and solids exceeding 25% of capacity | Settled solids reaching the outlet pipe invert (typically 8 inches deep), or the unit no longer capturing grease |
SAWS moved enforcement from lab sampling to this instant solids measurement under its 2012 ordinance. That means an inspector can open the lid, run a measuring stick down and write a violation on the spot. If your hauler pumps on a fixed calendar and your volume grows, you can fail between visits. Track your own measurements for a few months and set the pumping schedule from what you find.
How often must a grease trap be pumped?
As often as needed to stay under the 25% trigger, and never less often than your local minimum.
- San Antonio: the SAWS grease procedure manual sets a minimum of every 90 days for interceptors, more often if waste hits 25% of wetted depth. For interceptors of 100 gallons or less, SAWS best practice is weekly cleaning by your staff, and its tips say to clean and empty the whole unit at least once a month.
- Tampa: grease traps must be inspected, cleaned and maintained at least once a week. Each facility sets its own frequency above that.
- Houston, Dallas, Austin, Miami-Dade, Hillsborough County, Orlando and Jacksonville: each sets its own interval through its city code or utility FOG program. Get the current rule from Houston Public Works, Dallas Water Utilities, Austin Water, Miami-Dade's environmental and water departments, Hillsborough County Public Utilities, Orlando's Water Reclamation Division or JEA before you open, and ask whether they accept variances from the standard frequency.
What a full pump-out must include
SAWS spells out what a proper cleaning looks like, and it is a good standard anywhere:
- Pump off the floating grease, agitating the layer if needed.
- Put the vacuum hose all the way to the bottom to remove settled solids.
- Remove the water.
- Clean the sides and bottom.
- Check that the inlet and outlet sanitary tees are clear and tight and the baffles are in place.
- Look for cracks or defects.
- Seal the lids and give the owner a receipt.
SAWS says the interceptor must be left completely empty. Flushing it with hot water, chemicals or enzymes to dissolve grease and send it down the sewer is prohibited. Since the restaurant is the generator and is liable for the device, SAWS suggests the owner or a manager watch the cleaning.
Pump and return is illegal
Some haulers used to pump a trap, separate the grease on the truck and pour the water back in. Florida banned this through SB 1110, effective July 1, 2022 (Tampa notice). Fla. Stat. 403.0741 now says a hauler may not return grease waste or graywater to a grease interceptor or trap and must dispose of it only at a disposal facility. SAWS also prohibits haulers from putting removed water or material back into the city sewer except at approved disposal stations.
Do I need manifests for grease trap pumping?
Yes in both states, under different systems. Keep these records in the restaurant where an inspector can see them.
Florida: service manifests
Under Fla. Stat. 403.0741:
- The hauler documents every removal and disposal on a service manifest.
- The restaurant (the "originator") and the hauler both sign after removal, and the hauler leaves you a copy.
- The disposal facility and hauler sign after disposal. Within 30 days, the hauler sends copies to you and to the county and city.
- The manifest shows the condition of the trap, cleaning verification, the amount removed and disposed of, and the facility's ticket number.
- You and the hauler must keep a copy on site for 1 year.
- Inspecting agencies check that you have a hauler contract and documented pump-outs.
Tampa's Wastewater Department reviews these manifests during its annual inspections of food service establishments, publishes an approved grease hauler list and a hauler registration form, and has its own grease hauler manifest form.
Texas: TCEQ trip tickets
Grease trap waste is a regulated waste in Texas. Under 30 TAC 312.142, anyone who transports grease trap waste must register with TCEQ before operating, renew every two years, and carry a copy of the registration and a TCEQ sticker in each truck. Under 30 TAC 312.145, each load gets a trip ticket listing the transporter and its TCEQ registration number, the generator's name and signature, the type and amount of waste, the disposal site, and the volume of the grease trap. You receive a copy at pickup, and the transporter must return a completed copy within 15 days after the waste reaches the disposal facility. Transporters keep trip tickets for five years.
Local Texas programs add their own logs. SAWS's manual includes cleaning logs and states that maintenance and cleaning records must be kept for 3 years on some logs and 5 years on others. Keeping everything for 5 years covers both.
Before you hire a hauler, ask for
- Florida: proof the hauler is on your city or county's approved or registered list, and its disposal facility name.
- Texas: its current TCEQ registration number and the registration copy kept in the truck.
- A sample manifest or trip ticket, so you know what you will receive.
- A written price per pump-out that states the gallons included and what happens when the unit is larger or dirtier than expected.
San Antonio and Austin: local programs worth knowing
San Antonio (SAWS)
SAWS runs one of the most detailed FOG programs in Texas. Key points:
- The ordinance, effective January 1, 2012, raised inspections from once every three years to once a year and added a two-tier fee for food establishments.
- Each establishment that uses a grease interceptor must have it inspected at least once per calendar year by a licensed plumber or other qualified professional approved by SAWS, using the SAWS Certified Interceptor Inspector List. The inspector examines and photographs the inlet and outlet fittings, baffles, walls and floor after pumping and gives you a written report. Defects must be fixed within 90 days.
- Violators can be fined and face legal action.
- SAWS publishes best management practices, including scraping dishes, avoiding garbage disposals, recycling cooking oil and training staff.
Austin
Austin Water's Utility Compliance Services Division launched a Grease Trap Relief Program in November 2026, in response to City Council Resolution No. 20240530-165. It offers qualifying small businesses and charitable feeding organizations no-cost grease trap equipment and installation or replacement, using poly or fiberglass units. Approved applicants must prove ownership and sign an agreement to follow FOG best management practices, and the owner pays for all future maintenance and repairs. Austin Water says savings can reach $30,000 or more. Contact: AWGreaseTrapRelief@austintexas.gov.
Houston and Dallas
Both cities regulate grease traps through their city codes and water utilities. Before signing a lease or buying equipment, ask Houston Public Works or Dallas Water Utilities for the current permit, pumping-frequency, inspection and record-keeping rules, and get the answer in writing.
Tampa, Orlando, Miami-Dade and Jacksonville: Florida local programs
Tampa
- Traps must be inspected, cleaned and maintained at least weekly, and cleaned whenever captured material exceeds 25% of volume.
- Interceptors are pumped when settled solids reach the outlet pipe invert, when grease and solids exceed 25% of capacity, or when the unit stops capturing grease.
- Equipment must be approved by the Plumbing and Drainage Institute.
- Re-inspection is free if you pass; a failed re-inspection costs $61 for each hour inspectors spend on it.
- The Wastewater Director can refer noncompliance to the Code Enforcement Board, pursue criminal prosecution, or seek injunctions and civil damages.
- The facility pays for cleaning. It may hire a registered grease hauler or write its own cleaning protocol and clean the trap itself.
- Contact: Tampa Wastewater Department, 813-274-8070.
Orlando
Orlando's Water Reclamation Division runs a Grease Management Program. Food service establishments register by applying for a Grease Management Program Certificate on the city's permits site. Questions go to the Environmental Supervisor at 407-246-3086. The city also has a permit process for replacing a commercial underground grease interceptor.
Miami-Dade, Hillsborough County and Jacksonville
Restaurants in unincorporated Miami-Dade, Hillsborough County and Jacksonville (JEA) answer to county or utility FOG rules in addition to the state manifest law. Some Florida counties also require a separate annual permit for food service establishments and haulers. Pinellas County, for example, publishes a permit application, a variance-to-pumping-frequency application and a trap log form. Ask your county or utility which permits and logs apply. Fla. Stat. 403.0741 lets local governments adopt stricter rules than the state's, so the local rule controls when it is tougher.
What happens if I fail a FOG inspection?
Penalties climb with repeat violations and with any sewer overflow you cause.
- Florida state fines (Fla. Stat. 403.0741): up to $100 for each failure to provide or keep a manifest and up to $250 for each failure to clean a trap or interceptor. Unlawful disposal by a hauler brings a fine of at least $2,500 and a license suspension of at least 30 days; a repeat brings at least $5,000 and at least a 12-month revocation. Local governments can collect manifest fines and adopt stricter rules.
- Tampa: paid re-inspections after a failure, code enforcement board referral, and possible criminal or civil action.
- San Antonio: a 25% solids reading during inspection is a violation on its own; SAWS says violators can be fined and face legal action.
The bigger cost is often not the fine. A grease clog can back sewage up into your kitchen, forcing a closure until the line is cleared and the area cleaned. SAWS notes that FOG-clogged lines can overflow out of manholes into parking lots and streets. A utility can bill the business that caused a sewer overflow for cleanup, depending on its ordinance.
If you get a violation notice
- Read the deadline and the specific finding, such as solids depth, missing records or a broken baffle.
- Book a full pump-out and, if parts are damaged, a repair by a licensed plumber.
- Gather your manifests, trip tickets and cleaning logs.
- Respond in writing before the deadline with proof of the fix.
- Change your schedule or staff practices so it does not happen again, and keep a record that you did.
Who is responsible for the grease trap in a leased restaurant space?
The lease decides most of it, and many leases are vague. The utility usually holds the business operating the kitchen responsible for pumping and records, because it is the generator of the waste. Who pays to replace a cracked interceptor or upsize an undersized one is a lease question.
Lease clauses to negotiate before you sign
- Existing condition: require the landlord to deliver the interceptor pumped, inspected and in working order, with a written report and photos.
- Size and code compliance: if the city says the unit is too small for your menu and seats, who pays to replace it?
- Shared interceptors: in strip centers and food halls, several tenants may share one unit. Spell out how pumping costs and violations are split, and who holds the hauler contract.
- Routine pumping and records: usually the tenant. Make sure you get copies of manifests if the landlord contracts the hauler.
- Repairs to lids, baffles and pipes: state who pays for structural repairs versus routine parts.
- Sewer backups: state who pays for cleanup and lost business if the shared line clogs.
- End of lease: require a final pump-out and inspection so the next tenant starts clean.
This is general information, not legal advice. Have a commercial real estate attorney review the lease, and ask the local FOG program before signing whether the space has open violations. Our commercial plumbing guide covers related building systems.
Can I clean my own grease trap, and what does it cost?
Small under-sink traps: often yes, where the local rule allows it. Tampa lets a facility write its own cleaning protocol and clean its trap. SAWS encourages weekly cleaning of units of 100 gallons or less by staff and gives steps: let ice melt into the sink to harden grease, bail the water (it may go to the sanitary sewer), remove baffles if possible, dip the grease into a watertight container, scrape the sides, lid and baffles, then give the grease to a hauler or recycler or put it in the trash for pickup. Record the date, employee name and amount removed on a log.
Large in-ground interceptors: no. Removing and hauling the waste needs a pump truck and, in Texas, a TCEQ transporter registration. In Florida, the manifest law applies to haulers who remove grease waste.
Costs
Tampa estimates small traps (0 to 100 gallons) cost $250 to $1,500 to install, and new 750 to 1,500 gallon traps cost $4,000 to $8,500. We did not find a named, dated study of grease trap pumping prices in Texas or Florida. Pumping is usually priced per visit or per gallon, so get written quotes from at least two registered haulers that state the gallons included, disposal fees and any extra charges for heavy solids.
Best practices that cut pumping costs
The less grease and food that reaches the trap, the less often you pay to pump it. SAWS's best management practices include:
- Scrape plates and pans into the trash before washing.
- Never pour grease into sinks or toilets. Collect used fryer oil for a recycler.
- Avoid or limit garbage disposals. They grind food into small pieces that fill the trap.
- Use a three-compartment sink for wash, rinse and sanitize; SAWS notes it uses water under 140 F, while a dishwasher needs at least 160 F.
- Clean kitchen exhaust filters on a schedule so grease does not reach roof drains and storm drains.
- Put strainers in floor drains and sinks.
- Train new staff and keep a signed training log.
- Do not use enzymes or hot water to "dissolve" grease into the sewer; SAWS prohibits it, and the grease re-forms downstream.
How to choose a provider
- Confirm with the local plumbing official and FOG program what device size and type your kitchen needs.
- Get the sizing calculation in writing from a licensed plumber or engineer.
- Keep food waste disposers and sanitary waste out of the interceptor.
- Register or get a permit or certificate with your city or county FOG program if required.
- Hire a hauler on the local approved list (Florida) or with a current TCEQ registration (Texas).
- Measure grease and solids and pump before reaching 25% of depth or volume.
- Follow any local minimum interval, such as 90 days in San Antonio or weekly trap cleaning in Tampa.
- Insist on a full pump-out: no pump and return, no chemical or hot-water flushing.
- Keep manifests at least 1 year (Florida) and cleaning logs 5 years (to cover SAWS rules).
- Schedule the annual interceptor inspection if you are in San Antonio.
- Train staff on scraping, oil recycling and strainers, and log the training.
- Put grease trap duties, shared-unit costs and end-of-lease pumping in your lease.
Related plumbing guides
- What Plumbing Rules Apply to Small Businesses? Commercial Plumbing for Restaurants, Offices, Salons and Retail
- How Do I Unclog a Kitchen Sink, Bathroom Sink, Shower or Tub Drain?
- How Do I Know if My Main Sewer Line Is Clogged, and What Does It Cost to Clear?
- Sewage Coming Up Your Drains? What Do You Do, and Who Pays?
- Do You Need Annual Backflow Testing in Texas or Florida? Rules, Costs and Who Can Test
- Do I Need a Permit? Plumbing Permits and DIY Rules in Texas and Florida
- Septic or Sewer? How to Tell, Maintenance, Failure Signs, Conversion and the Rules in Texas and Florida
- How Do You Start a Plumbing Business in Texas or Florida? Licensing, Insurance and Operations
Plumbing by state and city
Questions people ask
How much does grease trap pumping cost?
We could not find a named, dated cost study for Texas or Florida, so treat any single number online with caution. Prices depend on the unit's size, how full it is, travel and disposal fees. Ask at least two haulers for written quotes that list gallons included and extra charges. For installation, Tampa estimates $250 to $1,500 for small traps and $4,000 to $8,500 for new 750 to 1,500 gallon traps.
Do food trucks need a grease trap?
The truck itself usually holds its wastewater in an onboard tank, but the commissary where it is serviced and where dishes are washed is a food preparation area under the plumbing code and generally needs a grease interceptor. Check with your city's health and FOG program, since the rules for mobile vendors and commissaries vary by city and county.
Can a grease interceptor connect to a septic system?
Yes, in places without sewer, but Florida treats it differently. Under FBC Plumbing 1003.3.9, interceptors serving onsite sewage systems are sized, built and approved under Rule 64E-6, F.A.C., and are required where grease could stop up lines or harm the septic system. In Texas, ask the TCEQ authorized agent that permits the septic system.
What is a grease trap manifest?
It is the record of one pump-out. In Florida, the service manifest is signed by the restaurant, the hauler and the disposal facility, shows the amount removed and the disposal ticket number, and must be kept on site for 1 year under Fla. Stat. 403.0741. In Texas, the equivalent is TCEQ's trip ticket under 30 TAC 312.145, which transporters keep for five years.
Are enzyme or bacteria treatments allowed?
Treat them with caution. SAWS prohibits using chemicals or other agents to dissolve or emulsify grease so it flows into the sewer, and also bans flushing interceptors with hot water. Products marketed as bacteria may be limited or banned by your local program. Ask your FOG inspector before using any additive, and never use one in place of pumping.
Who inspects grease traps?
Usually the sewer utility or city wastewater department, not the health department, although health inspectors may note grease problems. SAWS requires a yearly inspection by a licensed plumber or SAWS-approved professional and also inspects itself. Tampa's Wastewater Department inspects food service establishments annually and reviews hauler manifests.
What if my building's interceptor is shared with other restaurants?
Get the arrangement in writing. Many programs hold each generator responsible, so one tenant's grease can trigger a violation for everyone. The lease should name who holds the hauler contract, how costs are split, who keeps the manifests, and how violations and backup cleanup costs are shared.
Is there help paying for a grease trap in Austin?
Yes. Austin Water's Grease Trap Relief Program, launched in November 2026, offers qualifying small businesses and charitable feeding organizations no-cost grease trap equipment and installation or replacement. The business or property owner signs an agreement to follow FOG best practices and pays for future maintenance. Apply through the program page or email AWGreaseTrapRelief@austintexas.gov.
Sources
- Florida Building Code - Plumbing 2023 (8th Ed.), Chapter 10 Traps, Interceptors and Separators (UpCodes)
- Fla. Stat. 403.0741 Grease waste removal and disposal
- City of Tampa - Florida restaurants now facing stronger regulations for grease disposal
- City of Tampa - Grease Ordinance Frequently Asked Questions
- City of Tampa - Calculate Grease Trap Size
- City of Orlando - Grease Management Program
- SAWS - Fats, Oils and Grease Abatement Program
- SAWS - Annual Interceptor Inspection
- SAWS - FAQs: Everything You Wanted to Know About Grease
- SAWS - Grease Procedure Manual (PDF)
- City of Austin - Austin Water Grease Trap Relief Program Now Live
- 30 TAC 312.142 Registration requirements (LII)
- 30 TAC 312.145 Trip tickets (LII)
- Pinellas County - Commercial Grease Management
- City of Dallas Building Inspection - Plumbing and Mechanical
- City of San Antonio DSD - Codes and Ordinances
This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.