HVAC for Restaurants, Salons, Gyms and Retail: Ventilation, Make-Up Air and Peak Heat

Why a restaurant stays hot with the AC running, how make-up air and building pressure work, what codes require for kitchens, salons and gyms, and how Texas and Florida businesses can control heat and humidity without guesswork.

A restaurant usually stays hot even with AC because the kitchen hood exhausts large amounts of air and the building cannot replace it properly. Codes require make-up air approximately equal to the exhaust whenever the hood runs. Without enough tempered make-up air, the building goes negative, pulling hot, humid outdoor air through doors and gaps, overloading the rooftop units. The fix is to measure exhaust and supply, balance the system, temper make-up air, and size cooling for the kitchen's real heat load.

Key facts

  • The Florida Mechanical Code requires makeup air approximately equal to the exhaust air whenever commercial kitchen exhaust systems operate (FMC 508.1).
  • Makeup air may not differ from the conditioned space by more than 10°F unless the added heating and cooling loads stay within the HVAC system's capacity (FMC 508.1.1).
  • Type I hoods are required where cooking appliances produce grease or smoke (FMC 507.2).
  • Florida's minimum ventilation table lists dining rooms at 7.5 cfm of outdoor air per person plus 0.18 cfm per square foot, with a default density of 70 people per 1,000 square feet (FMC Table 403.3.1.1).
  • Beauty and nail salons need 20 cfm per person plus 0.12 cfm per square foot of outdoor air and 0.6 cfm per square foot of exhaust; each manicure and pedicure station needs source capture exhausting at least 50 cfm (FMC Table 403.3.1.1, note h).
  • Health club weight rooms and aerobics rooms need 20 cfm of outdoor air per person plus 0.06 cfm per square foot (FMC Table 403.3.1.1).
  • Florida's Division of Hotels and Restaurants adopted the 2017 FDA Food Code, effective November 1, 2019.
  • EPA recommends keeping indoor relative humidity below 60%, ideally 30% to 50%.
  • Florida law (s. 448.106, created in 2024) bars cities and counties from requiring employers to meet heat exposure rules beyond state or federal law; Texas HB 2127 (2023) preempts local ordinances on employment topics including breaks.
  • OSHA's proposed federal heat injury and illness rule was still at the proposed stage as of late 2026; the informal public hearing ended July 2, 2025.

Why is my restaurant so hot even with AC?

Restaurant owners in Houston, San Antonio, Miami and Orlando often add more AC tonnage and still have a hot kitchen and a muggy dining room. The usual reason is not too little cooling. It is too little replacement air.

A kitchen hood is a big exhaust fan. Every cubic foot of air it pulls out of the building has to come back in from somewhere. If a dedicated make-up air unit does not supply it, the building goes into negative pressure and pulls air in through every gap: the front door, the back door, ceiling cavities, roof penetrations and even the plumbing vents. In a Texas or Florida summer, that incoming air is hot and very humid. Your rooftop units then fight both the outside heat and a flood of moisture, and they lose.

Common causes, in rough order

  1. Not enough make-up air for the hood exhaust, or a make-up air unit that is broken, filthy or turned off to "save money."
  2. Untempered make-up air: outdoor air dumped straight into the kitchen at 95°F and high humidity.
  3. Hood exhaust set too high for the cooking line, or hood fans running all day at full speed.
  4. RTUs undersized for the actual load, often after a menu change, new equipment, or a retail space converted to a restaurant.
  5. Dirty condenser coils coated with grease from nearby exhaust fans on the roof.
  6. Poor air distribution: supply diffusers aimed away from the line, return grilles in the wrong place.
  7. Heat from equipment: fryers, char-broilers, ovens, dish machines and ice machines dumping heat into the space.
  8. Open doors at the drive-through window, delivery door or patio.

Each of these can be measured. Ask a commercial HVAC contractor or a test-and-balance firm to measure hood exhaust, make-up air supply, RTU outdoor air and building pressure, not just refrigerant pressures.

What is make-up air?

Make-up air (MUA) is outdoor air brought in on purpose to replace air that exhaust systems remove. In a restaurant, it is usually supplied by a dedicated make-up air unit on the roof, sometimes built into the hood itself (a compensating hood), and sometimes partly by the RTUs' outdoor air dampers.

The Florida Mechanical Code, which is based on the International Mechanical Code, sets the core rules:

  • Amount: makeup air must be supplied whenever commercial kitchen exhaust systems run, and the total must be approximately equal to the exhaust air for all exhaust systems in the building (FMC 508.1).
  • Temperature: the temperature difference between makeup air and the conditioned space may not exceed 10°F, unless the added heating and cooling loads of the makeup air are within the HVAC system's capacity (FMC 508.1.1). In a Florida or Texas summer, that means either cooling (tempering) the make-up air, or proving the RTUs can handle the untempered air.
  • Compensating hoods: manufacturers must label them with the minimum exhaust flow and maximum makeup airflow (FMC 508.2).

Texas cities adopt their own editions of the International Mechanical Code, so check with your local building department (Houston, Dallas, San Antonio and Austin each enforce locally adopted codes). The make-up air principle is the same.

Tempered vs. untempered make-up air

TypeWhat it doesTypical trade-off
UntemperedBrings in raw outdoor airLower equipment cost; very hot, humid air in Texas and Florida summers; must meet the 10°F rule or prove capacity
Heated onlyWarms air in winterHelps Dallas and north Texas winters; no summer help
Cooled (DX or chilled)Cools and dehumidifies make-up airHigher cost; much more comfortable kitchen; less load on RTUs
Energy recovery (where allowed)Pre-conditions incoming air using exhaust airUsually not used with grease-laden kitchen hood exhaust; may suit general exhaust

What is negative building pressure?

Building pressure is the small difference between indoor and outdoor air pressure. If more air is exhausted than supplied, the building is negative. If more is supplied than exhausted, it is positive.

Signs your building is negative

  • The front door is hard to open or slams shut.
  • Hot air rushes in when the door opens.
  • Smells from the kitchen or restrooms drift into the dining room, or sewer smells appear from floor drains.
  • Gas water heaters or fryers have trouble venting or pilot lights flicker. Negative pressure can pull combustion gases back into the building, which is a carbon monoxide risk. Have gas appliances and venting checked.
  • Condensation or sweating on supply grilles and ceiling tiles.
  • Ceiling tiles lift or move when the hood starts.

What "balanced" looks like

For most restaurants, the goal is a dining room that is slightly positive and a kitchen that is slightly negative compared with the dining room, so cooking odors and heat stay in the kitchen and go up the hood, while the building as a whole does not suck in outside air. A test-and-balance contractor measures airflows with instruments and adjusts fan speeds and dampers to reach the design. Ask for the written balance report.

Retail stores in strip centers can go negative too, from restroom exhaust or a shared wall with a restaurant. If your store's door whistles, ask your landlord about building pressure.

Does a kitchen hood affect my AC?

Yes, more than anything else in a restaurant. Three effects stack up:

  1. Air removal. The hood removes conditioned air. If make-up air is not tempered, the AC must treat the replacement air.
  2. Moisture. Outdoor air in Houston, Tampa or Miami carries a lot of water vapor in summer. Removing that moisture is a large part of the cooling load. EPA recommends indoor relative humidity below 60% to limit mold.
  3. Grease. Hood exhaust fans discharge grease-laden air on the roof. If RTU condenser coils are nearby and downwind, grease coats them, cutting capacity and raising energy use. Coil cleaning schedules should reflect this.

Type I hoods are required where cooking produces grease or smoke (FMC 507.2). Hood exhaust rates are set by the hood's listing and the cooking equipment. Running a hood at full speed when only one fryer is on wastes conditioned air. Many newer hood systems use demand-controlled ventilation that ramps exhaust and make-up air up and down with cooking activity, which can cut both fan and cooling energy. Ask your hood and HVAC contractors whether your system can be controlled this way and still meet code and the hood's listing.

How many tons of AC for a restaurant?

There is no reliable square-foot rule. Restaurants vary too much: a coffee shop, a pizzeria with a deck oven, and a Tex-Mex restaurant with char-broilers have very different loads. Cooling must be sized with a commercial load calculation that includes:

  • Building envelope: walls, roof, windows (west-facing glass in Texas afternoons is a big one).
  • People: dining room occupancy at peak.
  • Ventilation air: code-required outdoor air, set by occupancy.
  • Make-up air: any untempered or partly tempered replacement air for hoods.
  • Kitchen equipment heat: heat that escapes the hood (radiant heat from the line), plus unhooded equipment like ice machines, coffee brewers, dish machines and reach-in refrigerators that reject heat into the room.
  • Lighting.
  • Humidity removal (latent load), which is large in Texas Gulf Coast and Florida climates.

A worked ventilation example

Using Florida's minimum ventilation table for a 2,000-square-foot dining room: the default density is 70 people per 1,000 square feet, so about 140 people. Outdoor air is 7.5 cfm per person plus 0.18 cfm per square foot: (140 × 7.5) + (2,000 × 0.18) = 1,050 + 360 = 1,410 cfm of outdoor air at design occupancy, before any system adjustments the code applies. All of that outdoor air must be cooled and dried. The kitchen adds its own ventilation and exhaust: kitchens are listed at 7.5 cfm per person plus 0.12 cfm per square foot of outdoor air, with 0.7 cfm per square foot of exhaust, and hood exhaust is on top of that.

That is why restaurant HVAC design is usually done by a mechanical engineer or design-build contractor, not by matching the old unit's size. If you are converting a retail bay into a restaurant, the existing RTU almost never fits the new use. See commercial rooftop units and who pays under your lease.

Kitchen heat and your staff

A hot kitchen is a comfort problem and a safety problem. Line cooks in Texas and Florida kitchens can face high heat for long shifts.

Federal rules

OSHA has no final federal heat standard as of this writing. OSHA published a proposed Heat Injury and Illness Prevention rule on August 30, 2024; the comment period closed January 14, 2025; an informal public hearing ran from June 16 to July 2, 2025; and the post-hearing comment period ended October 30, 2025. OSHA lists no final rule. In the meantime, OSHA enforces heat hazards under the General Duty Clause of the OSH Act, which requires a workplace free from recognized hazards likely to cause death or serious harm, and runs a National Emphasis Program on heat (directive CPL 03-00-024). OSHA encourages water, rest and shade, and gradual acclimatization for new workers.

State and local rules

  • Florida: a 2024 law (ch. 2024-80, creating s. 448.106) bars counties and cities from requiring employers to meet heat exposure requirements beyond state or federal law, including rules on water, rest, shade, training and recordkeeping.
  • Texas: HB 2127 (2023, effective September 1, 2023) added Labor Code §1.005, which bars cities and counties from adopting or enforcing ordinances in fields the Labor Code occupies, expressly including breaks. That reaches local ordinances on worker rest or water breaks. HB 2127 has been the subject of litigation; check its current legal status, and any local rule, with an employment attorney before relying on either.

Practical steps for kitchens

  • Fix make-up air and tempering first; it lowers kitchen temperature more than anything else.
  • Add spot cooling at the line where the design allows.
  • Keep hood filters clean so exhaust captures heat and grease.
  • Provide water and scheduled breaks, and train staff to spot heat illness signs. CDC lists people working in heat among higher-risk groups.

How do salons handle chemical fumes with HVAC?

Hair and nail salons use products with strong odors and chemicals, such as solvents, acrylic monomers and hair treatments. Codes treat salons as spaces that need both extra outdoor air and dedicated exhaust.

Florida code requirements

  • Outdoor air: beauty and nail salons are listed at 20 cfm per person plus 0.12 cfm per square foot, with a default density of 25 people per 1,000 square feet (FMC Table 403.3.1.1). That people rate is much higher than retail's 7.5 cfm per person.
  • Exhaust: 0.6 cfm per square foot of general exhaust (Table 403.3.1.1). Barber shops are listed at 0.5 cfm per square foot.
  • Nail stations: each manicure and pedicure station needs a source capture system exhausting at least 50 cfm (note h). Stations without factory-installed exhaust inlets need inlets within 12 inches horizontally and vertically of where chemicals are applied (FMC 502.20).
  • Operation: nail station exhaust controls must run the system continuously whenever the space is occupied (FMC 502.20.1).
  • No recirculation: air from spaces where the table requires mechanical exhaust, such as beauty salons and barber shops, may not be recirculated to other spaces, though air may be recirculated within the space itself (FMC 403.2.1).

Texas salons follow the mechanical code their city has adopted, which is typically based on the same International Mechanical Code framework. Confirm local requirements with your building department before building out.

Practical tips

  • Locate exhaust close to the source, and keep it running during all open hours.
  • Make sure there is enough make-up or outdoor air so exhaust fans actually move air; a sealed salon with a strong exhaust fan simply goes negative.
  • Change RTU filters often; product overspray and hair load filters fast.
  • Keep humidity in check; EPA recommends below 60%.
  • Salon shampoo areas add moisture. Good exhaust helps.

What HVAC does a gym need?

Gyms combine high occupancy, high heat output from bodies and machines, and lots of moisture from sweat and showers. A gym that feels sticky is usually under-ventilated, under-dehumidified, or both.

Ventilation

Florida's ventilation table lists health club and aerobics rooms at 20 cfm of outdoor air per person plus 0.06 cfm per square foot, with a default density of 40 people per 1,000 square feet; weight rooms at the same rates with 10 people per 1,000 square feet (FMC Table 403.3.1.1). Example: a 3,000-square-foot group exercise room at default density holds about 120 people, so (120 × 20) + (3,000 × 0.06) = 2,400 + 180 = 2,580 cfm of outdoor air at design occupancy. That is a lot of hot, humid air to treat in Houston or Tampa.

Dehumidification

  • Right-size the cooling: oversized units cool the air quickly and shut off before removing enough moisture.
  • Consider equipment with dehumidification modes, such as hot gas reheat on RTUs, or a dedicated outdoor air system (DOAS) that dries outdoor air before it enters.
  • Demand-controlled ventilation can reduce outdoor air when class rooms are empty, if allowed by code and properly commissioned.
  • Locker rooms and showers need their own exhaust.

Air movement

Large ceiling fans make people feel cooler at a given temperature and spread conditioned air, which can let you raise the thermostat a little. They do not reduce humidity.

Target humidity below 60% (EPA) to limit mold in mats, carpets and locker areas. See humidity and mold.

Can high humidity hurt my retail inventory?

Yes. Humid air causes problems that show up as lost sales:

  • Paper and packaging: curling, soft boxes, labels that peel.
  • Clothing, shoes and leather: musty smells and mold.
  • Electronics: condensation risk where cold air meets humid air.
  • Food and supplements: clumping, spoilage, shortened shelf life.
  • Wood furniture and musical instruments: swelling and warping.
  • Floors: slippery entry areas when humid air meets cold floors.

EPA recommends keeping indoor relative humidity below 60%, ideally 30% to 50%, and says drying water-damaged materials within 24 to 48 hours usually prevents mold. Place a few inexpensive humidity loggers around the store and back room for a week, especially in summer. If readings stay above 60%, ask your contractor about outdoor air settings, oversized units, fan settings (fan "on" all the time can re-evaporate moisture off a wet coil back into the space), and dehumidification options.

Back rooms and storage areas often get little supply air. A store can feel fine at the register while stock in the back is sitting in 70% humidity. Check both.

What temperature should a store be kept at?

Neither Texas nor Florida law sets a required thermostat temperature for retail stores. The right setting balances customer comfort, staff comfort, inventory, and energy cost.

Practical factors:

  • Humidity first. A store at 76°F and 50% humidity often feels better than one at 72°F and 65% humidity. Keep relative humidity below 60%.
  • Door traffic. Stores with constant door openings see big swings near the entrance. Vestibules or air curtains can help.
  • Lighting and display heat. Older lighting and spot lights add heat.
  • Staff in motion. Stockers and warehouse staff may need cooler conditions than cashiers.
  • After hours. Setbacks save energy, but in Florida and Gulf Coast Texas a deep summer setback can let humidity climb overnight. Set a humidity limit in the controls if available.

Check your lease too. Some shopping center leases require tenants to keep HVAC running during center hours or keep the space within a set range.

Are there health code temperature rules for restaurants?

Florida

The Florida Department of Business and Professional Regulation's Division of Hotels and Restaurants licenses, inspects and regulates public food service establishments under Chapter 509, Florida Statutes. The Division adopted the 2017 FDA Food Code, effective November 1, 2019. The Food Code sets food temperature rules for cold and hot holding and includes facility rules such as ventilation; those govern food and facilities rather than setting a dining room air temperature. You can search inspection results online through the Division.

Texas

The Texas Department of State Health Services' Retail Food Establishment group licenses and inspects restaurants, food stores and similar businesses in areas without a local health department, and many Texas cities and counties run their own health departments under state food rules. DSHS provides a jurisdiction map to find who inspects your location. In Houston, Dallas, San Antonio and Austin, the local health department generally handles restaurant inspections.

What this means for HVAC

  • Health codes do not tell you what tonnage to install or what thermostat setting to use.
  • They do care about outcomes HVAC affects: condensation dripping on food or food-contact surfaces, grease and smoke not being captured, mold on ceilings, and refrigeration equipment that cannot hold food temperatures because the kitchen is too hot.
  • Walk-in coolers and reach-ins reject heat into the kitchen and lose capacity when kitchens are very hot. A kitchen that runs at 95°F makes it harder to keep food at safe temperatures.

For the exact rules on your operation, contact your local health department or DBPR, and confirm any specific number in the current rule text.

Walk-in coolers, ice machines and refrigeration heat

Refrigeration equipment moves heat from food into the room or to the outdoors. In a restaurant or convenience store, that heat is a hidden part of the HVAC load.

  • Self-contained units (reach-ins, ice machines with built-in condensers) dump heat into the kitchen. Many ice machines are available with remote condensers that reject heat outdoors.
  • Walk-in coolers and freezers usually have condensing units outside or on the roof. Keep their coils clean, just like RTUs.
  • Licensing: in Texas, commercial refrigeration work needs a contractor with the Commercial Refrigeration and Process Cooling or Heating endorsement (Occ. Code §1302.254). Florida AC contractors' scope includes refrigeration systems; confirm the license class on DBPR.
  • Refrigerant rules: anyone who opens the refrigerant circuit must hold EPA Section 608 certification. EPA leak repair requirements apply to appliances with a full charge of 50 pounds or more of ozone-depleting refrigerant, which can include some larger supermarket systems.

Designing for peak heat in Texas and Florida

Peak days are when businesses lose customers. A few design and operating choices make the difference:

  • Size for real loads, not old units. Use a load calculation that includes ventilation, make-up air and equipment.
  • Plan redundancy. Two smaller RTUs often beat one large one: if one fails on a 100°F Saturday, you still have partial cooling.
  • Protect condenser airflow. Keep RTUs clear of exhaust discharge, signage and debris. Clean coils before summer.
  • Pre-cool before opening. Start systems early on hot days rather than trying to catch up after the lunch rush starts.
  • Shade and roof: a reflective roof and shaded west glass reduce load.
  • Controls: programmable or networked thermostats with schedules for prep, open and closed hours; lockouts to stop staff from setting 60°F.
  • Storm and outage plans: in hurricane season, secure rooftop equipment and know how to restart safely after power returns. Florida rooftop equipment must be installed to resist code wind pressures (FMC 301.15). See hurricane prep and power outages and generators.

Maintenance schedule for food service and high-use spaces

ItemWhy it matters in restaurants, salons and gyms
RTU filtersGrease, hair and lint load filters fast; clogged filters cut airflow and freeze coils
Condenser coilsGrease from nearby hood exhaust coats coils on the roof
Evaporator coils and drain pansHigh humidity means lots of condensate; dirty pans grow mold and clog drains
Make-up air unitFilters, belts, burners or cooling coil; if MUA fails, the building goes negative
Hood exhaust fan and filtersClean filters capture heat and grease; fire code cleaning schedules also apply
Economizers and outdoor air dampersA stuck-open damper floods the space with humid air
Controls and sensorsSchedules, humidity limits, demand ventilation sensors
Balance checkRe-check after menu, hood or equipment changes

Write maintenance requirements into a preventive maintenance contract with a licensed contractor, and keep the reports. Many leases require them. See our RTU maintenance section.

Questions to ask a commercial HVAC contractor

Not every residential AC company is set up for restaurants, salons or gyms. Before hiring, ask:

  1. How many commercial kitchens (or salons, or gyms) have you serviced in the last year? Can I call two of them?
  2. Will you measure hood exhaust, make-up air and outdoor air, or bring in a test-and-balance firm?
  3. Do you service make-up air units and economizers, or only the RTUs?
  4. What is your coil cleaning method for grease-coated condenser coils?
  5. What is your emergency response time on a Friday night in July, and what does it cost?
  6. Does your license class cover all my units? (Class B in Texas and Florida is limited to 25 tons cooling per system.) Do you hold the Texas Commercial Refrigeration endorsement if you will touch my walk-in?
  7. Will you give me written service reports with readings after every visit?
  8. Will you coordinate with my hood cleaning and fire suppression vendors?

A contractor that only offers to "add a ton" without measuring airflow is not diagnosing the problem. See how to choose an HVAC contractor.

Converting a space: retail to restaurant, salon or gym

Changing a space's use is where HVAC surprises cost the most. Before you sign a lease for a conversion:

  1. Get the existing equipment data: every RTU's model, serial, tonnage, age and condition.
  2. Ask a mechanical designer for a preliminary load and ventilation estimate for the new use. Compare the outdoor air rates: retail sales at 7.5 cfm per person and 0.12 cfm per square foot versus salons at 20 cfm per person, gyms at 20 cfm per person, and kitchens with hood exhaust plus make-up air.
  3. Check the roof: can it hold a new make-up air unit, a hood exhaust fan and additional RTUs? Is there space and structural capacity?
  4. Check utilities: gas capacity for kitchen equipment and gas-fired make-up air; electrical capacity for added cooling.
  5. Negotiate who pays for HVAC upgrades in the lease. See commercial lease HVAC.
  6. Budget for permits and inspections: mechanical, electrical, plumbing, fire (hood suppression), and health department plan review for food service.
  7. Use licensed contractors: TDLR in Texas, DBPR in Florida, with license class matched to system size (Class B up to 25 tons cooling in both states).

How to choose a provider

  • Measure hood exhaust, make-up air supply, RTU outdoor air and building pressure.
  • Confirm make-up air runs whenever the hood runs, and is tempered if the 10°F rule cannot be met.
  • Check for signs of negative pressure: hard-to-open doors, drafts, odors, venting problems.
  • Have gas appliance venting checked if the building runs negative.
  • Clean RTU condenser coils near hood exhaust before peak summer.
  • Place humidity loggers in the sales floor and back rooms; aim for below 60%.
  • Salons: confirm continuous exhaust at nail stations (50 cfm source capture each) and general exhaust.
  • Gyms: confirm outdoor air rates and dehumidification capability.
  • Get a commercial load calculation before converting a space or replacing units.
  • Sign a preventive maintenance contract that includes the make-up air unit and economizers.
  • Train kitchen staff on heat illness signs and provide water and breaks.
  • Confirm health department and building department requirements before any buildout.

Related ac and heating guides

AC and heating by state and city

Questions people ask

Can I just add a bigger AC unit to fix a hot kitchen?

Usually not. If the real problem is missing or untempered make-up air, a bigger RTU fights the same flood of hot, humid air and may short-cycle, leaving the dining room cold and clammy while the kitchen stays hot. Measure exhaust and make-up air first. Fixing make-up air, balancing, and coil cleaning often costs less and works better than adding tonnage.

Why does my restaurant's front door slam shut?

That is a classic sign of negative building pressure: the hood exhausts more air than the building supplies, so outdoor air pressure pushes the door closed. It also means hot, humid air is entering through every gap. Have the make-up air unit checked for operation and airflow, and ask a balancing contractor to measure building pressure.

Do I need a separate make-up air unit?

Most commercial kitchens with a Type I hood need a planned make-up air source, because code requires makeup air approximately equal to the exhaust. That can be a dedicated make-up air unit, a compensating hood, or outdoor air from RTUs if the design accounts for it and meets the 10°F temperature rule or proves capacity. Your mechanical designer and building department determine which approach fits your kitchen.

Is it safe to turn off the make-up air unit to save money?

No. Turning off the make-up air unit while the hood runs sends the building negative. That pulls in hot, humid outside air, can draw odors and smoke into the dining room, can hurt hood capture, and can pull combustion gases back from gas appliances. It also violates the code requirement that makeup air be supplied whenever kitchen exhaust runs.

How often should restaurant RTU filters be changed?

More often than in an office. Grease and dust load filters quickly, especially near the kitchen. Many restaurants change filters on a monthly or more frequent schedule during heavy use, but the right interval depends on your equipment and environment. Ask your contractor to inspect filters at each visit and set the schedule based on how dirty they get.

My salon smells like chemicals all day. What should I check?

Check that each nail station has working source capture exhaust running continuously while open, that general exhaust fans are running, and that the HVAC brings in enough outdoor air for the fans to work. Florida's code requires at least 50 cfm of source capture exhaust per manicure and pedicure station. A blocked or undersized exhaust duct, a dead fan motor, or a sealed space with no make-up air are common causes.

Do gyms need dehumidifiers?

Many gyms in Texas and Florida benefit from dedicated dehumidification or HVAC equipment with dehumidification features, because high occupancy and outdoor air bring in a lot of moisture. Oversized RTUs that short-cycle make it worse. Measure humidity during busy classes. If it stays above 60%, ask your contractor about reheat options, a dedicated outdoor air system or other dehumidification.

Who inspects restaurant HVAC: the health department or the building department?

Both, for different things. The building department permits and inspects the mechanical systems, hoods and make-up air during construction or replacement. The fire department or fire marshal is typically involved with hood fire suppression. The health department, or DBPR's Division of Hotels and Restaurants in Florida, inspects food safety and sanitation, which includes conditions HVAC affects, like condensation, mold and ventilation.

Can I run my RTU fan on 'on' all the time for better air?

It depends. Continuous fan can help ventilation and mixing, but in humid climates it can blow moisture off a wet cooling coil back into the space between cooling cycles, raising humidity. Many systems are set to run the fan continuously during occupied hours for ventilation and cycle with cooling after hours. Ask your contractor to set fan and ventilation modes for your use and humidity goals.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration