A propane tank's size sets how many days your standby generator can run before you need a truck. Here is the runtime math from manufacturer fuel tables, why you only get about 80% of the tank, and the Texas and Florida rules on leased tanks and refills.

For a typical 20 kW air-cooled home generator, a 500-gallon tank holds about 400 usable gallons and runs roughly 7 days at half load, 4 to 5 days at full load and about 10 days at quarter load (our calculation from one manufacturer's fuel table). A 250-gallon tank, the minimum one maker allows, gives about half that. Most Texas and Florida homes that want a week of hurricane or freeze coverage choose 500 gallons or more.

Key facts

  • One manufacturer says propane tanks feeding its home standby generators must be at least 250 gallons, and larger tanks may be needed depending on installation, fuel demand or climate.
  • One manufacturer's 20 kW air-cooled model burns 59, 82, 109 and 136 cubic feet per hour of LP vapor at 25%, 50%, 75% and 100% load, about 1.6, 2.3, 3.0 and 3.7 gallons per hour (gallons are our calculation).
  • The same maker converts LP vapor at 36.39 cubic feet per gallon and 8.58 cubic feet per pound.
  • Federal OSHA rule 29 CFR 1910.110 sets maximum LP-gas filling densities by weight so containers are never filled completely with liquid; for propane-weight product in an above-ground tank of 1,200 gallons or less the limit is 42% to 43% by weight, which works out to roughly 80% of the tank's volume.
  • EIA reported residential propane at $3.209 a gallon in Texas and $5.167 in Florida for the week of Nov. 16, 2026, versus $2.817 nationally.
  • Florida statute 527.07 says only the owner of an LP-gas container, or someone the owner authorizes, may fill or refill it.
  • Florida 527.067(4) requires a Category I LP gas dealer to give at least 5 business days' written or electronic notice before shutting off a consumer's system, except in a known hazard.
  • Texas rule 16 TAC 9.31 lets the Railroad Commission declare a regional LP-gas supply emergency and ask loading racks to give priority to trucks bound for affected counties.

Quick answer: runtime by tank size

The table below is our calculation. We took one manufacturer's published LP fuel use for three common generator sizes, converted it to gallons, and divided it into 80% of each tank's water capacity (the usual maximum fill). Real runtime will be shorter if the tank was not full, if the same tank also feeds a furnace, water heater or range, or if your average load is higher than you think.

GeneratorLoadGallons per hour250-gal tank (200 usable)500-gal tank (400 usable)1,000-gal tank (800 usable)
14 kW air-cooled25%1.2162 hrs (6.7 days)323 hrs (13.5 days)647 hrs (27 days)
14 kW air-cooled50%1.6121 hrs (5.1 days)243 hrs (10.1 days)485 hrs (20.2 days)
14 kW air-cooled75%2.197 hrs (4.0 days)194 hrs (8.1 days)388 hrs (16.2 days)
14 kW air-cooled100%2.290 hrs (3.7 days)180 hrs (7.5 days)359 hrs (15 days)
20 kW air-cooled25%1.6123 hrs (5.1 days)247 hrs (10.3 days)493 hrs (20.6 days)
20 kW air-cooled50%2.389 hrs (3.7 days)178 hrs (7.4 days)355 hrs (14.8 days)
20 kW air-cooled75%3.067 hrs (2.8 days)134 hrs (5.6 days)267 hrs (11.1 days)
20 kW air-cooled100%3.754 hrs (2.2 days)107 hrs (4.5 days)214 hrs (8.9 days)
38 kW liquid-cooled25%3.066 hrs (2.8 days)132 hrs (5.5 days)265 hrs (11 days)
38 kW liquid-cooled50%4.247 hrs (2.0 days)95 hrs (3.9 days)189 hrs (7.9 days)
38 kW liquid-cooled75%5.536 hrs (1.5 days)73 hrs (3.0 days)146 hrs (6.1 days)
38 kW liquid-cooled100%6.730 hrs (1.2 days)60 hrs (2.5 days)119 hrs (5.0 days)

Fuel figures come from the manufacturer's spec sheets for its 14RCA, 20RCA and 38RCLA models at 60 Hz. Other brands of the same size burn similar but not identical amounts, so look up the fuel table on your own unit's spec sheet and redo the math with the formula in the next section.

How to calculate your own runtime

You need three numbers: tank water capacity, your generator's propane use at your expected load, and how full the tank is.

  1. Usable gallons. Multiply the tank's water capacity by 0.80 (the usual maximum fill), then by the gauge reading as a fraction of that. Example: a 500-gallon tank reading 70% on its gauge holds about 350 gallons. (Most tank gauges read percent of total volume, so 70% on the dial is 70% of 500, not of 400. Ask your supplier how your gauge reads.)
  2. Gallons per hour. Find the LP consumption table on your generator's spec sheet. If it is in cubic feet per hour, divide by 36.39 to get gallons. If it is in Btu per hour, divide by 91,452, the heat content of a gallon of propane according to the U.S. Energy Information Administration.
  3. Hours. Divide usable gallons by gallons per hour.

Worked example (our calculation): a Tampa family has a 500-gallon buried tank filled to 80% in June, so 400 gallons. Their 20 kW generator averages about half load with one AC zone cycling, burning about 2.25 gallons an hour. 400 divided by 2.25 equals about 178 hours, or a little over 7 days of nonstop running. If they also cook and heat water with propane from the same tank, they should knock that down by the gas those appliances use.

What load should I plan for?

Very few homes run at 100% for hours on end. A central air conditioner cycles, and big loads like a dryer or oven run only part of the time. Your average load depends on your home and habits, so look at your own usage: in Texas, advanced meter data belongs to the customer under Utilities Code 39.107(b), and the Smart Meter Texas portal or your utility's account portal shows your usage history; Florida utilities' online accounts show usage charts. Our load calculation guide shows how.

Stretch your fuel

  • Raise the thermostat a few degrees in summer, or lower it in winter.
  • Run the dryer, dishwasher and oven one at a time, and not at all if the outage may be long.
  • Turn off pool pumps and other non-essential loads. A load management module can do this automatically; see whole-house vs essential circuits.
  • In a very long outage, some owners shut the generator down overnight in mild weather. Never run a portable generator indoors to make up for it.

Why can a propane tank only be filled to about 80%?

Liquid propane expands a lot as it warms. A tank filled to the brim on a cool morning could build dangerous pressure on a hot afternoon, so the law requires room for expansion.

Federal OSHA rule 29 CFR 1910.110 sets the maximum "filling density," the weight of LP-gas in a container compared with the weight of water it would hold at 60 F. For product with a specific gravity of 0.504 to 0.510, the limit is 42% for above-ground tanks of 1,200 gallons or less, 45% for larger above-ground tanks and 46% for underground tanks. The rule also requires each tank filled by volume to have a fixed liquid-level gauge set to the maximum fill level, based on the liquid volume at 40 F for above-ground tanks and 50 F for underground ones.

When you run those weights through the rule's own formula for propane, the maximum works out to roughly 80% of the tank's volume, which is why the industry rule of thumb is "80% full." (The conversion is our calculation; your supplier fills to the tank's fixed gauge, not to a number.) Texas and Florida apply their own adopted editions of NFPA 58, the LP-Gas Code, which governs filling; Texas adopted the 2017 edition through Railroad Commission rules and Florida adopted the 2024 edition through FDACS rule 5J-20.002, effective Nov. 17, 2026.

So a "500-gallon tank" is a water-capacity size. Plan on about 400 gallons of propane when it is full, 200 in a 250-gallon tank and 800 in a 1,000-gallon tank.

What size propane tank do I need for my generator?

Start with the manufacturer's minimum and then size for the outage you are planning around.

  • Minimum: one manufacturer says its home standby generators need a propane tank of at least 250 gallons, for runtime and to keep fuel pressure adequate. Check your own generator's installation manual.
  • Fuel pressure: one manufacturer's spec sheets require 7 to 11 inches of water column of LP vapor at the generator inlet. The tank, first-stage regulator and second-stage regulator must deliver that while the generator runs at full load.
  • Outage target: pick the number of days you want to run without a refill, then use the table above.
Generator sizeMinimum we would plan forFor about a week at half loadFor two weeks or a shared house tank
10 to 14 kW250 gal (manufacturer minimum)250 to 500 gal500 gal
18 to 22 kW250 gal500 gal1,000 gal
24 to 26 kW500 gal500 to 1,000 gal1,000 gal or more
30 to 48 kW liquid-cooled500 gal1,000 galMore than 1,000 gal or multiple tanks

This is planning guidance derived from the runtime table, not a code requirement. Your propane installer will size the tank and regulators for your total load, climate and site under the LP-gas code your state enforces. Placement distances, buried vs above-ground options and permits are in our propane tank installation rules guide.

Does cold weather affect propane and generator performance?

Yes. A home standby generator burns propane as a vapor. The liquid in the tank has to boil off fast enough to keep up, and it boils off more slowly when the tank is cold and when the liquid level is low, because there is less wetted steel to soak up heat from the air. A small tank feeding a big generator in a freeze can lose pressure even when it still has fuel in it.

That is why one manufacturer says larger tanks may be needed "depending on climate," and why the RRC notes that a larger consumer tank lets you ride out supply shortages. We could not load an authoritative published vaporization chart (the NFPA 58 handbook and industry charts were not available to us), so we do not print one. If you live in the Texas Panhandle, North Texas or anywhere a Uri-type freeze is possible, ask your propane installer to size the tank for vapor withdrawal at your lowest expected temperature, not just for runtime.

Cold also affects the engine. One manufacturer offers carburetor, battery and oil heater kits for units that must start in temperatures below 32 F or 0 F. These plug in to keep parts warm and are worth asking about in North Texas and the Panhandle. Our Texas grid outage guide covers winter prep.

Practical freeze tips

  • Keep the tank above 50% going into a freeze forecast; a fuller tank vaporizes better.
  • Keep snow and ice off the regulator vent and tank dome.
  • Never heat a propane tank with a flame or heater.

Can I run a standby generator on 100-pound cylinders?

Generally not as the main supply. A 100-pound cylinder holds 100 pounds of propane, about 858 cubic feet of vapor using the manufacturer's conversion of 8.58 cubic feet per pound. A 20 kW generator at half load burns 82 cubic feet an hour, so one cylinder lasts about 10 hours (our calculation). You would need two to three cylinders a day, and a small cylinder in cool weather may not vaporize fast enough to hold pressure at full load.

That is also why one manufacturer requires at least a 250-gallon tank. Some smaller standby units and portable generators are designed around cylinders; follow the manual for your model. A bank of cylinders with an automatic changeover regulator is a custom LP-gas system that must be installed by a licensed propane installer (RRC-licensed in Texas, FDACS-licensed in Florida). For portable options, see our portable generator buying guide.

Can the generator share my house propane tank?

Yes, if the tank and regulators are sized for everything at once. When the power is out, you may be running the generator, a gas furnace or water heater, and a gas range at the same time. One manufacturer's installation manual says LP supply pressure must stay within range and the system must supply the generator at rated load plus other gas appliances.

Two things to settle with your supplier:

  • Total vapor demand. Add up the Btu per hour of every connected appliance. One manufacturer lists the maximum LP fuel flow of its 20 kW air-cooled model at 340,000 Btu per hour. A 40,000 Btu water heater and a 60,000 Btu furnace push the total toward 440,000 Btu per hour.
  • Runtime. Every gallon the furnace burns is one the generator cannot. In a winter outage, a gas furnace can use a lot of fuel.

If the existing tank is small, a second tank dedicated to the generator, or a larger replacement tank, may be the better fix.

Should I buy or lease a propane tank?

This is a contract question as much as a fuel question.

Leased tankOwned tank
Upfront costLower; supplier owns and installsYou pay for the tank and setting
Who can fill itUsually only the owner (the supplier) or someone it authorizesYou choose the licensed supplier
Maintenance and inspectionsOften the supplier's job under the leaseYour responsibility, with a licensed company
Price shoppingLimited while you leaseYou can compare suppliers
Switching or movingRemoval or pump-out terms in the leaseTank stays with the property

Florida: who may fill a tank

Florida statute 527.07(1) says a person other than the owner, and those the owner authorizes, may not fill, refill, remove gas from, deliver or use any LP-gas container. Section 527.07(2) adds that only people the end user authorizes may add gas to or remove gas from a container holding propane the end user bought. So if your supplier owns the tank, a different supplier generally cannot fill it without the owner's authorization. Under 527.067(4), a Category I dealer must give at least 5 business days' written or electronic notice before rendering your system inoperable or discontinuing service, unless it knows of a hazard. Violations of chapter 527 are a second-degree misdemeanor under 527.08. FDACS licenses LP gas dealers and installers; check a license on the FDACS LP gas page before you sign.

Texas: who may fill a tank

We reviewed the Railroad Commission's LP-gas safety rules (16 TAC chapter 9) and Natural Resources Code chapter 113 and did not find a provision equivalent to Florida's 527.07 on filling a container owned by another company, so your lease is the controlling document. What the RRC rules do say: anyone filling a container must inspect it and may not fill one that is dented, bulged, gouged or badly corroded (rule 9.137), and a licensee may not put gas into any container or system it believes is unsafe or not installed to the rules (rule 9.135). Companies that install, service or sell LP-gas equipment need an RRC license. If you have a dispute over a leased tank, read the lease's termination and removal terms and contact RRC Alternative Fuels Safety for safety questions.

General information, not legal advice. For a contract dispute, talk to an attorney.

How do I keep the tank full before hurricane season or a freeze?

Propane trucks can only reach you when roads are open, and every customer calls at once when a storm is forecast. Plan ahead:

  • Florida: top off in spring before hurricane season starts, and again as soon as a storm enters the forecast cone. Ask your supplier about automatic delivery, where they schedule fills from your usage, or tank monitoring.
  • Texas: fill in fall before the first freeze, and again when a hard freeze is forecast. Gulf Coast homes should also fill before hurricane season.
  • Know your tank's gauge. Check it monthly; one manufacturer's maintenance schedule calls for a weekly check of the main tank supply level.
  • Budget for the fill. At EIA's Nov. 16, 2026 prices, filling 300 gallons cost about $963 in Texas and $1,550 in Florida (our calculation, excluding delivery fees and taxes).

How long does a refill take after a storm?

There is no official number, and it varies from hours to many days depending on road access, the supplier's backlog and regional supply. The Railroad Commission's rule 9.31 exists because regional LP-gas shortages happen: it lets the Commission declare a supply emergency and ask terminals to load trucks for the affected counties first. The RRC's propane FAQ says cold weather early in the heating season can push prices up and that a larger consumer tank lets you last through shortages. The safe assumption is that you will not get a refill for the first several days after a major hurricane or freeze, so size the tank for that.

Do propane tank monitors work for generator fuel?

Yes. A tank monitor is a sensor that reads the tank's float gauge and reports the level by cellular or Wi-Fi signal to your phone or to the supplier. For a generator tank, that solves two problems: you can see the level from anywhere during an outage, and an automatic-delivery supplier can schedule a refill before the tank gets low.

Things to ask:

  • Does the monitor need power or Wi-Fi that will be lost in an outage? Cellular, battery-powered units are more useful during storms.
  • Who owns the monitor and the data, especially on a leased tank?
  • Can you set a low-level alert, for example at 40%?
  • Does installing it require opening the gauge, which on a leased tank may need the owner's permission?

A monitor does not change how much fuel you have. It just makes sure you know in time.

Generator propane use during weekly exercise

Standby generators run themselves on a schedule to keep the engine and alternator healthy. One manufacturer says weekly or every-two-weeks exercise is required, and its default unloaded exercise runs 20 minutes. Its 20 kW model burns about 35 cubic feet of LP an hour while exercising, about 0.96 gallon per hour. That is about 0.3 gallon per exercise and roughly 17 gallons a year at a weekly schedule (our calculation). Factor that into your fill schedule so a dry summer does not leave the tank low in September. More in our maintenance and exercise schedule guide.

How to choose a provider

  • Look up your generator's LP fuel table on its spec sheet.
  • Estimate your average outage load (use smart meter data if you can).
  • Multiply tank water capacity by 0.80 to get usable gallons.
  • Divide usable gallons by gallons per hour to get runtime, then subtract other appliances on the same tank.
  • Meet at least the generator maker's minimum tank size and the LP inlet pressure range.
  • In freeze-prone areas, ask the installer to size for vapor withdrawal at your coldest expected temperature.
  • Read the lease: who may fill, who maintains, removal terms and fees.
  • Confirm the supplier and installer licenses (RRC in Texas, FDACS in Florida).
  • Fill before hurricane season and before freeze forecasts; consider automatic delivery or a monitor.
  • Check the tank gauge regularly and after every long run.

Related standby generator installation guides

Standby generator installation by state and city

Questions people ask

How long will a 500-gallon propane tank run a 22 kW generator?

About a week at half load. A full 500-gallon tank holds about 400 gallons. A 20 to 22 kW air-cooled generator burns roughly 2.3 gallons an hour at half load and about 3.7 at full load on one manufacturer's fuel table, so 400 gallons lasts about 178 hours at half load and about 107 hours at full load (our calculation). Check your own model's spec sheet, since fuel use varies.

How long will a 250-gallon tank last on a whole-house generator?

A 250-gallon tank holds about 200 gallons of propane. On a 20 kW air-cooled generator that is roughly 3.7 days at half load or about 2.2 days at full load, using one manufacturer's fuel figures (our calculation). That is the minimum tank size one manufacturer allows. For hurricane or freeze outages that can last a week, most homeowners choose a larger tank.

How long will a 1,000-gallon tank run a generator?

About 800 usable gallons runs a 20 kW air-cooled generator roughly 15 days at half load and 9 days at full load, and a 38 kW liquid-cooled unit about 8 days at half load (our calculation from one manufacturer's spec sheets). If the tank also feeds a furnace, water heater or range, the generator's share is smaller.

How much propane does a generator use per hour at half load?

On one manufacturer's spec sheets, about 1.6 gallons an hour for a 14 kW air-cooled unit, about 2.3 for a 20 kW air-cooled unit and about 4.2 for a 38 kW liquid-cooled unit (gallons are our conversion at 36.39 cubic feet per gallon). Check the fuel table for your exact model.

Why is my propane tank only filled to 80%?

Propane liquid expands as it warms, so tanks must keep vapor space. Federal OSHA rule 1910.110 limits filling by weight and requires a fixed gauge set to the maximum level, which for propane works out to roughly 80% of the tank's volume. Texas and Florida enforce their adopted editions of NFPA 58, which governs how suppliers fill tanks. Plan on 400 gallons in a 500-gallon tank.

Can a new propane company fill a tank my old supplier owns?

In Florida, generally not without authorization. Statute 527.07 says only the owner of an LP-gas container, or someone the owner authorizes, may fill it. In Texas we did not find an equivalent Railroad Commission rule, so the lease controls. In either state, read the lease's terms on filling, removal and fees before you switch, and ask the old supplier to pick up or sell you the tank.

Does cold weather make a propane generator lose power?

It can. Propane must boil from liquid to vapor in the tank, and that slows as the tank gets colder and emptier. A small tank feeding a large generator in a hard freeze may not hold the 7 to 11 inches of water column pressure one manufacturer requires. Keeping the tank fuller and choosing a larger tank both help. Ask your installer to size for your coldest expected weather.

Is it cheaper to run a generator on propane in Texas or Florida?

Texas, by a wide margin at recent prices. EIA's Nov. 16, 2026 data put Texas residential propane at $3.209 a gallon and Florida at $5.167. At 2.25 gallons an hour, a 20 kW generator at half load costs about $7.23 an hour in Texas and about $11.64 in Florida (our calculation). Local supplier prices and delivery fees vary.

Should my generator propane tank be buried or above ground?

Both are allowed when installed to the adopted NFPA 58 rules. Buried tanks are out of sight and out of the wind, but Texas rule 16 TAC 9.116 requires a corrosion protection system on steel containers installed underground or mounded on or after March 1, 2014, and in flood zones you should ask how the tank will be secured. Above-ground tanks are easier to inspect and cheaper to set. Your propane installer and local permit office set the requirements; see our propane tank installation rules guide.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration