Local Guide · AC and heating
Is a Heat Pump Worth It in Texas and Florida? A Hot-Humid Climate Buying Guide
Heat pump advice is usually written for cold states. This guide covers what matters in the South: humidity control, sizing on the cooling load, heat strips, 2026 prices, rebates and refrigerants.
For most all-electric homes in Florida and much of Texas, a heat pump is worth it. It cools exactly like an AC and heats far more efficiently than electric heat strips, and both states need little winter heat: Florida logged about 563 heating degree days in 2025 and Texas about 1,624. It costs somewhat more than a straight AC. The federal tax credit ended after 2025, but utility rebates still apply. Size it on the cooling load with a Manual J.
Key facts
- The federal minimum for split-system heat pumps made since Jan. 1, 2023 is 14.3 SEER2 and 7.5 HSPF2, and it applies in Texas and Florida (10 CFR 430.32).
- ENERGY STAR split heat pumps must reach at least 15.2 SEER2, 11.0 EER2 and 7.8 HSPF2.
- In 2025, Florida logged 563 and Texas 1,624 population-weighted heating degree days, versus 6,053 in New York (NOAA CPC daily data, our sum).
- Florida's energy code requires heat pumps to be sized on the cooling load, at no more than 1.15 times the design cooling load (FBC-Energy R403.7.1.2.1).
- Trane's 2026 cost guide lists installed heat pumps at $8,313-$10,289 (single-stage) to $12,778-$15,608 (variable-speed).
- Trane says properly installed and maintained heat pumps are expected to last 15 to 20 years.
- The federal 25C credit is not allowed for property placed in service after Dec. 31, 2025, per the IRS.
- New residential heat pumps must use refrigerant with a GWP of 700 or less (effective Jan. 1, 2025); R-454B is GWP 470 and R-32 is GWP 675.
- Austin Energy pays $650 to $950 for qualifying heat pumps; Tampa Electric pays $550 for 16.20 SEER2 or higher.
Is a heat pump the same as an air conditioner?
In summer, yes. A heat pump is an air conditioner with one extra part, a reversing valve, that lets it run the refrigerant cycle backward in winter. In cooling mode it pulls heat out of your house and dumps it outside, exactly like a central AC. In heating mode it pulls heat from the outdoor air, even cool air, and moves it inside.
ENERGY STAR describes a ducted air-source heat pump as a central air conditioner that also works in reverse to heat the whole house, and says one can deliver up to three times more heat energy than the electricity it uses, because it moves heat rather than making it from fuel.
The parts
- Outdoor unit: compressor, outdoor coil, fan, reversing valve and defrost controls.
- Indoor unit: an air handler (blower plus indoor coil), usually in a closet, garage or attic. In gas homes, the indoor coil sits on top of a furnace instead.
- Backup heat: electric resistance coils (heat strips) in the air handler, or a gas furnace in a dual-fuel setup.
- Thermostat: must be heat-pump compatible so it controls the reversing valve and backup heat correctly.
So the real choice in Texas and Florida is not "heat pump or AC." It is how you want to make heat in winter: with a heat pump, with electric heat strips behind a straight AC, or with a gas furnace. Our heat pump vs gas furnace guide goes deeper on the gas side, and package units and split systems explains equipment layouts.
Is a heat pump worth it in Florida and Texas?
For most all-electric homes in Florida and much of Texas, yes. The case comes down to how much heating you need and what you heat with now.
How much heating the South actually needs
A heating degree day (HDD) measures how far a day's average temperature falls below 65°F. Using NOAA Climate Prediction Center daily population-weighted data, we summed 2025 totals by state:
| State | 2025 heating degree days | 2025 cooling degree days |
|---|---|---|
| Florida | 563 | 3,041 |
| Texas | 1,624 | 3,009 |
| New York | 6,053 | n/a |
| Minnesota | 8,173 | n/a |
Florida needs about a tenth of New York's heating, and Texas about a quarter, while both states led the lower 48 in cooling degree days in 2024 and 2025. That means the cooling side of the heat pump does most of the work, and the heating side runs in a mild climate where heat pumps are at their most efficient. North Texas (Dallas-Fort Worth, Amarillo, Lubbock) needs noticeably more heat than Miami or Tampa, which shifts the math somewhat. NOAA's state records show Texas has dropped as low as -23°F, while Miami International Airport has hit 32°F only six times since 1948 and not since 1989.
When a heat pump makes the most sense
- You heat with electric strips now. A heat pump uses far less electricity than resistance heat for the same warmth on most winter days.
- You are replacing a straight AC and air handler in an all-electric home anyway. The heat pump version costs somewhat more (see the price table below) but adds efficient heat.
- You do not have gas service, or your gas furnace is near the end of its life.
When a straight AC or dual fuel may make sense
- You have a newer gas furnace and only the AC failed. Pairing a heat pump with the furnace creates a dual-fuel system, which ENERGY STAR notes can be done at modest extra cost.
- You are in North or West Texas with cheap gas and long cold snaps, and want gas heat on the coldest nights.
- You are in a small South Florida condo with almost no heating need, where the upgrade from AC plus strips to a heat pump pays back slowly. Even there, many owners choose a heat pump for the few cold nights each winter.
Do heat pumps cost more than AC units? (2026 prices)
Yes, a little. Trane's 2026 cost guide, a manufacturer-published national estimate for its own equipment, installed and before tax, gives these ranges. Local Texas and Florida prices vary with home size, ductwork, access and permit costs, so treat these as a starting point.
| System (Trane 2026 cost guide) | Single-stage | Multi-stage | Variable-speed |
|---|---|---|---|
| Central air conditioner | $6,568 to $8,544 | $8,573 to $10,671 | $11,525 to $13,669 |
| Heat pump | $8,313 to $10,289 | $9,921 to $12,648 | $12,778 to $15,608 |
Trane lists installed air handler replacement at $5,172 to $8,742 depending on tier, and installed gas furnaces at $5,093 to $6,386 (80% AFUE) or $6,630 to $8,390 (96% AFUE). Because quotes often bundle the outdoor unit, air handler or furnace, coil, line set, thermostat and permit, compare total system prices line by line. Our AC replacement cost guide and quote comparison guide show how.
No federal tax credit in 2026
The federal Energy Efficient Home Improvement Credit (25C), which paid up to $2,000 a year for qualifying heat pumps, is not allowed for property placed in service after December 31, 2025, under the 2025 federal tax law, according to the IRS. Some older pages, including ENERGY STAR's heat pump product page as of this writing, still describe a credit through 2032. That is out of date. Use the IRS as the authority. See HVAC tax credit 2026.
Utility rebates that still pay
| Utility | Heat pump rebate (as published) | Key conditions |
|---|---|---|
| Austin Energy | $650 (15.2 SEER2/11.0 EER2/7.8 HSPF2), $750 (16.0/11.0/8.0), $950 (17.0/13.0/9.0) | Home and system 10+ years old, participating contractor, Manual J sizing, city permits, possible inspection |
| CPS Energy (San Antonio) | $90 to $310 per cooling ton depending on SEER2 tier and early replacement vs burnout | Heat pumps must reach at least 7.5 HSPF2; AHRI certificate; permit inside city limits |
| FPL | $200 instant rebate per qualifying unit, 15.2 SEER2 or higher | Participating contractor, full system replacement, AHRI match; excludes single-zone mini-splits |
| Tampa Electric (TECO) | $40 at 15.20 SEER2; $550 at 16.20 SEER2 or higher | Apply within 90 days; contractor shows rebate as a line item |
| JEA (Jacksonville) | $200 for ENERGY STAR heat pumps | Tier 1 split heat pump: 16 SEER2, 11.0 EER2, 8.0 HSPF2; AHRI certificate |
| Duke Energy Florida | Up to $1,000 for HVAC replacement after a free Home Energy Check (June 2025 news report; confirm at duke-energy.com) | Amounts from a June 2025 newspaper report; confirm at duke-energy.com/Rebates |
Rebate rules change often. Confirm the current amount with your utility before you sign. Full details are in our Texas rebates and Florida rebates guides.
Heat pump vs AC with heat strips vs dual fuel: side by side
| Feature | Heat pump + backup strips | Straight AC + heat strips | Dual fuel (heat pump + gas furnace) |
|---|---|---|---|
| Cooling | Same as an equivalent AC | Same | Same |
| Normal winter heating | Heat pump, efficient | Electric resistance, about 1 unit of heat per unit of electricity | Heat pump on mild days, gas below a set outdoor temperature |
| Very cold nights | Strips help as backup | Strips do all the work | Gas furnace |
| Upfront cost | Higher than AC | Lowest | Highest, unless the furnace is reused |
| Best fit | All-electric homes in FL and most of TX | Very low heating need, tight budget | Homes with gas and a good furnace, colder parts of TX |
| Code notes (Florida) | Must be sized on the cooling load | Resistance heat may not be the primary heat under the prescriptive path in Climate Zone 2 | Furnace work must be done by a contractor allowed to handle gas connections |
That last Florida point surprises people. Under the Florida energy code's prescriptive path, electric resistance heat may not be the primary heating system in Climate Zone 2 (FBC-Energy R403.7.2), which covers most of the state outside South Florida. Many projects use the performance path instead, but it explains why heat pumps are standard in Florida new construction. Electric resistance furnaces must also be sized within 4 kW of the calculated design load.
On gas: Florida Class A and B air-conditioning contractors may disconnect and reconnect gas appliances during a change-out but may not run new gas lines inside buildings; that work belongs to a mechanical contractor or gas-qualified trade. In Texas, ACR contractors who install LP-gas appliances need an exam exemption from the Railroad Commission. See our Florida license guide and Texas license guide.
Should I replace my heat strips with a heat pump?
If your home is heated only by electric strips in the air handler (common in older Florida homes and Texas apartments), switching to a heat pump is usually the biggest winter efficiency upgrade available. On a typical mild winter day, a heat pump delivers the same warmth with a fraction of the electricity.
You do not throw the strips away. Most heat pump air handlers keep a smaller strip heater as auxiliary heat: it helps during defrost and on the coldest mornings. The thermostat shows "aux heat" when strips are running. If you see aux heat running for hours on a 50°F day, something is wrong. Call a technician.
How to do it
- Replace the outdoor AC with a heat pump and the indoor unit with a heat-pump-matched air handler. Florida requires matched indoor and outdoor units on replacements, verified by AHRI data or another listed method (FBC-Energy R501.7).
- Install a heat-pump-compatible thermostat.
- Ask the contractor to size the backup strips to the load, not to the biggest kit available. Oversized strips can raise winter peak demand.
- Ask your utility whether a strip-to-heat-pump conversion qualifies for a rebate. We could not confirm a Duke Energy Florida strip-heat conversion rebate from Duke's own site, so check duke-energy.com/Rebates for current offers.
Do heat pumps dehumidify as well as AC?
In cooling mode, a heat pump removes moisture exactly the way an AC does: warm, humid air passes over the cold indoor coil, water condenses and drains away. A heat pump and an AC of the same size, staging and airflow perform the same in summer. The things that change dehumidification are sizing, staging and fan settings, not the heat pump label.
Dehumidification by compressor type
| Type | How it runs | Humidity performance in humid climates |
|---|---|---|
| Single-stage | On at full capacity or off | Good if correctly sized; poor if oversized because short runs cool the air before much water is removed |
| Two-stage | Low stage most of the time, high stage on hot afternoons | Longer, slower runs on low stage usually remove more moisture per hour of operation |
| Variable-speed (inverter) | Adjusts capacity across a wide range | Can run long and slow to control humidity, if the controls are set up for dehumidification; some setups prioritize temperature and let humidity drift |
Florida's energy code takes moisture seriously. Replacement cooling equipment must have latent (moisture-removal) capacity that meets the calculated latent load, and total capacity no more than 1.15 times the calculated load (FBC-Energy R403.7.1.1). Heat pumps must be sized on the cooling load, even when the heating load is higher (R403.7.1.2.1). In other words, the code requires a heat pump that is not oversized for summer, which is also what keeps humidity under control.
To get the best humidity control from any system: ask for a Manual J load calculation, use the fan's Auto setting (not On), ask the installer to set airflow for humid-climate dehumidification if the equipment allows it, and seal duct leaks in the attic. See humidity and mold, Manual J sizing and attic duct leaks.
Variable-speed vs single-stage heat pump in Texas and Florida
Single-stage units are simpler and cheaper. Variable-speed units cost more but run quieter and longer at low speed, hold temperature more evenly, and often handle humidity better. The price gap in Trane's 2026 guide between its single-stage and variable-speed heat pumps is about $4,500 to $5,300 at the low and high ends of each range.
Questions that decide it
- How long will you stay? Efficiency savings build over years.
- Is humidity a problem now? If you have clammy rooms or mold despite a working AC, a properly set-up variable-speed system can help, but fix duct leaks and sizing first.
- How is the ductwork? Variable-speed equipment is sensitive to undersized or leaky ducts. If the ducts are poor, a top-tier unit will not perform to its rating.
- Parts and service. Variable-speed systems use inverter boards and communicating controls. Repairs can cost more, and some parts are brand-specific. Ask about parts availability in your area. See who makes what AC brand.
- Rebates. Higher tiers often earn larger rebates. Austin Energy's top heat pump tier pays $950; TECO pays $550 at 16.20 SEER2 or higher.
Two-stage equipment sits in between and is a common choice for Texas and Florida homes that want better humidity control without the full cost of variable speed.
What SEER2 and HSPF2 ratings matter in the South?
SEER2 (Seasonal Energy Efficiency Ratio 2) measures cooling efficiency over a season. EER2 measures cooling efficiency at a hot, steady condition, which is closer to a Texas or Florida afternoon. HSPF2 (Heating Seasonal Performance Factor 2) measures heating efficiency over a season. These "2" ratings replaced SEER and HSPF for equipment made on or after January 1, 2023.
| Standard | SEER2 | HSPF2 | EER2 |
|---|---|---|---|
| Federal minimum, split heat pump (national, applies in TX and FL) | 14.3 | 7.5 | none set for the Southeast |
| Federal minimum, packaged heat pump | 13.4 | 6.7 | none set for the Southeast |
| ENERGY STAR, split heat pump | 15.2 | 7.8 | 11.0 |
| ENERGY STAR, packaged heat pump | 15.2 | 7.2 | 10.0 |
For split air conditioners under 45,000 Btu/hr, Texas and Florida (DOE's Southeast region) require 14.3 SEER2, higher than the 13.4 national minimum. For split heat pumps there is no separate regional minimum; the 14.3 SEER2 and 7.5 HSPF2 national minimum applies. See SEER2 and HSPF2 explained and the 2023 regional standards.
Where to spend in a mild-winter climate
In Florida, with very little heating, HSPF2 matters much less than SEER2 and EER2. Paying extra for a high HSPF2 makes little sense in Miami. In North Texas, HSPF2 matters more because the heat pump runs more hours in winter. In both states, EER2 is worth a look because it reflects performance on the hottest afternoons, when your bill and grid demand peak. Several utilities, such as Austin Energy and JEA, use EER2 in their rebate tiers for this reason.
Always check ratings on the AHRI certificate for your exact matched outdoor unit, indoor coil or air handler, and furnace. The combination is what is rated, not the outdoor unit alone. Utilities including CPS Energy, FPL and JEA require the AHRI certificate for rebates.
What size heat pump do I need?
The right size comes from an ACCA Manual J load calculation, not square footage rules of thumb. Florida's energy code requires heating and cooling equipment to be sized with ACCA Manual S based on Manual J (or another approved method) loads, prohibits safety factors, and requires heat pumps to be sized on the cooling load with no more than 1.15 times the design cooling load. Austin Energy requires Manual J or its own sizing guidance for rebates, and Oncor may require a Manual J for its program.
A heat pump sized correctly for summer may not cover the whole heating load on the coldest night in Dallas or Lubbock. That is what backup strips or a dual-fuel furnace are for. In Florida, the cooling-based size almost always covers most winter hours. Ask your contractor for the Manual J report, the design temperatures used, and the heat pump's capacity at those temperatures. See our sizing guide.
What is a reversing valve, and what is defrost mode?
The reversing valve is a four-way valve in the outdoor unit that switches the direction of refrigerant flow. In one position, the indoor coil is cold (cooling). In the other, it is warm (heating). A click and a short whoosh when the system switches modes is normal.
Defrost mode happens in heating season. When the outdoor coil is cold and the air is damp, frost builds on it. The system briefly switches to cooling mode to warm the outdoor coil and melt the frost, while aux heat warms the indoor air so you do not feel a cold blast. You may see steam rising from the outdoor unit and hear the fan stop. This is normal on cold, humid mornings in North Florida and Texas. A unit encased in solid ice that never clears is not normal. See frozen coil guide and winter heating repair.
Why heat pump air feels cooler than gas heat
A gas furnace sends out very hot air in short bursts. A heat pump sends out warm air for longer periods. The air feels less hot to your hand, but it heats the house. Owners switching from gas often call this a defect. It usually is not.
Are heat pumps loud?
Outdoor heat pumps sound like outdoor ACs, because in summer they are the same machine. Variable-speed models are usually quieter most of the time because they run at low speed. In winter you may also hear the reversing valve click and defrost cycles. Manufacturers list sound levels in decibels on spec sheets; compare those numbers for models you are considering. Placement matters: keep the unit away from bedroom windows and a neighbor's patio, on a level pad, with proper clearance. Rattles, grinding or screeching are not normal. See noises and smells guide.
How long do heat pumps last in Florida and Texas?
Trane says properly installed and maintained heat pumps are expected to last 15 to 20 years, and air conditioners about 15. A heat pump runs in both seasons, so it logs more hours each year than a straight AC, but in Florida the heating hours are few. Coastal salt air shortens outdoor coil and cabinet life; see coastal corrosion. Annual maintenance, clean filters (ENERGY STAR recommends checking monthly) and a clear condensate drain matter more than brand. See AC lifespan by age and maintenance checklist.
Which heat pump brands are most reliable?
We do not rank brands, and we have not found an independent, published reliability study for Texas and Florida heat pumps that we can cite. Surveys you see online often come from affiliate sites or small samples. What the evidence and the codes do support: installation quality, correct sizing, proper refrigerant charge, airflow and duct condition drive performance and failure rates more than the logo. Florida law even states the Legislature's intent that replacement AC systems be installed with quality installation procedures, including sizing analysis and duct inspection (section 553.912).
Practical brand questions to ask instead:
- Is there a local distributor stocking parts in my metro?
- What is the parts and compressor warranty, and does it require registration? See warranty registration.
- Does the installer offer a labor warranty, and for how long?
- Which refrigerant does it use (R-454B or R-32), and does the installer have A2L training and tools?
See who actually makes each AC brand for ownership and refrigerant choices.
Refrigerants: what changed for new heat pumps
New residential AC and heat pump systems must use refrigerant with a global warming potential (GWP) of 700 or less, under EPA's Technology Transitions rule effective January 1, 2025. Most new equipment uses R-454B (GWP 470) or R-32 (GWP 675), both classed A2L, mildly flammable. R-410A (GWP 2,090) is restricted for new systems.
Under EPA's May 26, 2026 final rule, effective July 27, 2026, residential systems whose components were all made or imported before January 1, 2025 can still be installed with no deadline. So you may still be offered an R-410A heat pump from inventory. That can be legal, but ask how R-410A service costs may change: EPA itself acknowledged R-410A for recharging older systems is likely to rise in price as the HFC phasedown continues. Texas buyers should also know TDLR's published FAQ describes comfort-AC refrigerants in terms of nonflammable A1 types; ask your contractor how they follow current TDLR rules and manufacturer instructions for A2L equipment. See refrigerant transition guide.
How to choose a provider
- Find out how you heat now: electric strips, gas furnace or an older heat pump.
- Ask for an ACCA Manual J load calculation and keep the report.
- Get at least three written quotes listing the outdoor unit, indoor unit, AHRI certificate number, SEER2, EER2 and HSPF2.
- Decide on staging: single, two-stage or variable-speed, based on humidity, ducts and budget.
- Ask how backup heat will be sized and how the thermostat controls it.
- Check your utility's current heat pump rebate and its paperwork before signing.
- Ask which refrigerant the system uses and whether the installer is trained for A2L equipment.
- Confirm the contractor's license (TDLR in Texas, DBPR in Florida) and that a permit will be pulled.
- Register the equipment for the manufacturer warranty within the deadline.
- After install, set the thermostat to Cool or Heat (not Auto) and fan to Auto, and watch for long aux heat runs.
Related ac and heating guides
- Heat Pump or Gas Furnace in Texas and Florida: Which Heats Better and Cheaper?
- What Are SEER2, EER2 and HSPF2? Which Efficiency Rating Matters in Texas and Florida
- What Size AC Do I Need? Manual J, Tonnage Myths and the Rule-of-Thumb Trap
- How Much Does a New AC or Heat Pump Cost in 2026? What a Fair Texas or Florida Quote Includes
- How Do I Keep My Florida or Gulf Coast Home Below 60% Humidity and Stop AC Mold?
- Texas AC and Heat Pump Rebates by Utility: Austin Energy, CPS Energy, Oncor, CenterPoint and More
- Florida AC and Heat Pump Rebates: FPL, Duke Energy, TECO, JEA, OUC and More
- R-22, R-410A, R-454B and R-32: What Does the Refrigerant Transition Mean for You in 2026?
AC and heating by state and city
Questions people ask
Is a heat pump worth it in Florida?
For most all-electric Florida homes, yes. Florida logged only 563 population-weighted heating degree days in 2025 versus 3,041 cooling degree days, so the unit mainly cools and heats efficiently on the few cold nights. If you now heat with electric strips, a heat pump uses much less electricity for winter heat. The upfront premium over a straight AC is modest.
Is a heat pump the same as an AC?
In cooling mode, yes. A heat pump is an air conditioner with a reversing valve that lets it run backward to heat. In summer it cools and dehumidifies the same way as an AC of the same size and staging. In winter it moves heat from outdoor air into the house, with heat strips or a gas furnace as backup.
Do heat pumps cost more than AC units?
A little. Trane's 2026 cost guide lists installed single-stage heat pumps at $8,313 to $10,289 versus $6,568 to $8,544 for its single-stage central ACs. Variable-speed heat pumps run $12,778 to $15,608. These are manufacturer national estimates for one brand; local Texas and Florida quotes vary, and utility rebates can offset part of the cost.
Do heat pumps dehumidify as well as AC?
Yes. In cooling mode they remove moisture the same way. Dehumidification depends on correct sizing, compressor staging, airflow and fan settings. Oversized single-stage units short cycle and remove less water. Two-stage and properly set variable-speed systems run longer at low speed and usually control humidity better. Florida's energy code requires latent capacity to meet the calculated moisture load.
What size heat pump do I need?
Get an ACCA Manual J load calculation. Florida's energy code requires Manual J and Manual S sizing and says heat pumps must be sized on the cooling load, at no more than 1.15 times the design cooling load. In colder North Texas, backup strips or a gas furnace cover the coldest nights. Ask your contractor for the written report.
Variable-speed vs single-stage heat pump in Texas?
Variable-speed units cost more but run quieter, hold temperature evenly and often control humidity better. Single-stage units are simpler and cheaper to repair. Two-stage sits in between. Decide based on how long you will stay, humidity problems, duct condition, rebates and local parts availability. Poor ducts will hold back any top-tier system.
How long do heat pumps last in Florida?
Trane says properly installed and maintained heat pumps are expected to last 15 to 20 years. Coastal salt air can shorten outdoor unit life, so homes near the beach may see less. Annual maintenance, clean filters, clear condensate drains and rinsing the outdoor coil help. Installation quality has a large effect on lifespan.
What is a reversing valve?
It is a four-way valve in the outdoor unit that switches the direction of refrigerant flow, so the system can either cool or heat. A brief click and whoosh when it changes modes, or during defrost, is normal. A failed reversing valve can leave a heat pump stuck in one mode, which needs a licensed technician to diagnose.
Are heat pumps loud?
Outdoor heat pumps sound like outdoor ACs, and variable-speed models are usually quieter because they run at low speed. In winter you may hear defrost cycles and the reversing valve. Compare decibel ratings on spec sheets and place the unit away from bedrooms. Grinding, screeching or loud rattles mean it needs service.
Which heat pump brands are most reliable?
We have not found an independent, published reliability study for Texas and Florida heat pumps that we can cite, and we do not rank brands. Installation quality, sizing, charge and ductwork drive reliability more than the logo. Ask about local parts stock, warranty terms and registration, the installer's labor warranty, and A2L refrigerant training.
What HSPF2 matters in the South?
The federal minimum for split heat pumps is 7.5 HSPF2, and ENERGY STAR requires 7.8. In Florida's mild winters, HSPF2 matters less than SEER2 and EER2, so paying for a very high HSPF2 rarely pays back. In North Texas, where heat pumps run more winter hours, a higher HSPF2 has more value. Check ratings on the AHRI certificate.
Should I replace heat strips with a heat pump?
Usually yes, if you heat only with electric strips. A heat pump delivers the same warmth with far less electricity on most winter days. Keep smaller strips as auxiliary heat for defrost and very cold mornings. Florida requires matched indoor and outdoor units on replacement. Ask your utility about rebates before you sign.
Is there a federal tax credit for heat pumps in 2026?
No. The IRS says the Energy Efficient Home Improvement Credit (25C) is not allowed for property placed in service after December 31, 2025. Some websites, including ENERGY STAR's heat pump page, still describe a credit through 2032, which is outdated. Utility rebates from Austin Energy, CPS Energy, FPL, TECO, JEA and Duke Energy Florida may still apply.
Sources
- 10 CFR 430.32, Energy conservation standards (eCFR)
- ENERGY STAR, Air-Source Heat Pumps
- ENERGY STAR, Air-Source Heat Pumps and Central AC Key Product Criteria
- NOAA CPC, 2025 daily population-weighted heating degree days by state
- NOAA CPC, 2025 daily population-weighted cooling degree days by state
- EIA, Degree days explained
- NOAA State Climate Extremes Committee records
- NOAA State Climate Summaries 2025: Florida
- Florida Building Code, Energy Conservation (2023), Residential Chapter 4
- Florida Building Code, Energy Conservation (2023), Existing Buildings
- Florida Statutes §553.912, Air conditioners
- Trane, 2026 HVAC Pricing Guide
- IRS, One Big Beautiful Bill provisions (25C termination)
- IRS, Energy Efficient Home Improvement Credit
- Austin Energy, AC and heat pump rebates
- CPS Energy, HVAC rebate specifications
- FPL, Residential HVAC Program Standards
- Tampa Electric, Heating and cooling rebates
- JEA, Heating and Cooling Rebates
- West Orange Times & Observer, Duke Energy expands rebate program (June 10, 2025)
- EPA, Technology Transitions HFC restrictions by sector
- Federal Register, May 26, 2026 Technology Transitions final rule
- EPA SNAP, Substitutes in residential and light commercial AC and heat pumps
- TDLR, Air Conditioning and Refrigeration FAQ
- Florida Statutes Chapter 489, Contracting
This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.


