Why Is My Heater Not Working? Heat Pump, Heat Strip and Furnace Troubleshooting for Texas and Florida Winters

A plain-English guide to Southern heating problems: heat pumps blowing cool air, defrost steam, emergency heat, furnaces that will not light, freeze prep for Texas and the winter bill spikes Florida families see during cold snaps.

A heat pump that blows lukewarm air in winter is often working normally: heat pump air feels cooler than furnace air, and the unit pauses heating to defrost its outdoor coil, which causes steam and a whooshing sound. Real problems include a dirty filter, wrong thermostat mode, a tripped breaker, a stuck reversing valve, low refrigerant or a failed defrost control. Gas furnaces most often fail from a dirty flame sensor, bad ignitor or blocked vent.

Key facts

  • In 2020, 19% of Texas homes and 31% of Florida homes used a central heat pump as their main heating equipment, and 61% of Texas and 33% of Florida homes used a furnace (gas or electric), per EIA.
  • The federal minimum for split-system heat pumps made since Jan. 1, 2023 is 14.3 SEER2 and 7.5 HSPF2, and that national minimum applies in Texas and Florida (10 CFR 430.32).
  • Florida's Energy Code (R403.1.3) requires heat pumps with electric backup heaters to have controls that limit backup heat to times when the compressor cannot meet the setting, during defrost, or when the heat pump or thermostat malfunctions.
  • Florida's Energy Code (R403.1.2) requires new programmable thermostats to ship set to no higher than 70 degrees F for heating and no lower than 78 degrees F for cooling.
  • ENERGY STAR advises heat pump owners not to set back the thermostat when away or asleep, to avoid Auto mode, and to clean filters when visibly dirty.
  • ENERGY STAR notes outdoor heat pump units release water when they defrost in winter, which can form icy patches.
  • Since 1948, Miami International Airport has dropped to 32 degrees F or lower only 6 times, and not once since 1989, per NOAA; Texas's record low is minus 23 degrees F.
  • Texas DSHS confirmed 246 deaths tied to the February 2021 winter storm; 158 were from hypothermia, and 107 of those people were 60 or older.

First: is your heat pump actually broken?

Most homes in Florida and many in Texas heat with a heat pump, not a furnace. EIA's 2020 survey found heat pumps are the main heating equipment in 31% of Florida homes and 19% of Texas homes. Many other homes have an "electric furnace," which is an air handler with electric heat strips. If you are not sure what you have, look at the outdoor unit's label: a heat pump label usually says "heat pump," and the thermostat often has an "Em Heat" or "Aux" setting.

Heat pumps confuse people because they behave differently from a gas furnace:

  • The air feels cooler. A gas furnace blows air that feels hot to your hand. A heat pump moves heat from outdoors to indoors, and its supply air often feels only warm, especially on the coldest days. If the house is slowly warming up, the system is likely fine.
  • It runs for long stretches. On a 25 degree night in Dallas or Lubbock, a heat pump may run almost nonstop. That is normal when it is very cold outside, because the heat pump is designed to run longer at lower output rather than blast in short bursts.
  • It steams and whooshes. When frost builds up on the outdoor coil, the heat pump switches into defrost mode for a few minutes. You may hear a loud whoosh when the valve shifts, see a cloud of steam rise off the unit, and notice the outdoor fan stop. That is defrost, not a fire and not a breakdown.

Signs that something is wrong: cold air (not just mild air) that never warms up, the outdoor unit encased in a solid block of ice that does not clear within an hour or two, the outdoor unit not running at all while the indoor fan blows, the house temperature dropping steadily, or a breaker that keeps tripping.

Why is my heat pump blowing cold air?

Work through these causes from easiest to hardest.

CauseWhat you noticeDIY stepNeeds a tech?
Thermostat set to Cool or Auto, or fan set to OnCool air between cycles, or cold air in heat modeSet mode to Heat and fan to AutoNo
Defrost cycleCool air for a few minutes, steam outsideWait several minutesNo, unless it repeats constantly
Dirty filterWeak airflow, unit runs and runsReplace the filterNo
Outdoor unit tripped or offIndoor fan runs, outdoor unit silentCheck the breaker and outdoor disconnect switchYes if it trips again
Blocked outdoor unitLeaves, mulch or a cover on the unitClear a couple of feet around it; remove coversNo
Stuck reversing valveCold air in heat mode, warm in cool mode, or stuck in one modeNoneYes
Low refrigerant (a leak)Weak heat, heavy icing, long run timesNone (refrigerant work requires EPA certification)Yes
Failed defrost board or sensorOutdoor coil stays iced solidShut off and call; you can run emergency heat meanwhileYes
Bad capacitor or contactorOutdoor unit hums but fan or compressor will not startNone (high voltage)Yes

The reversing valve explained

The reversing valve is the part that lets a heat pump switch between heating and cooling. The thermostat sends a signal to an electric coil on the valve. If the coil fails or the valve sticks, the heat pump keeps cooling when you want heat. A technician can test the coil, which is often a simpler repair than replacing the valve itself. Replacing a valve means opening the refrigerant circuit, which must be done by an EPA Section 608 certified technician. See our EPA 608 guide.

Refrigerant leaks

A heat pump that is low on refrigerant heats poorly and ices up. Topping off without finding the leak is a short-term fix. The rules on R-22 and R-410A, and what the 2025 refrigerant transition means for repairs, are covered in our refrigerant leak guide and refrigerant transition guide.

The defrost cycle: steam, whooshing and ice

When it is cold and damp outside, moisture in the air freezes on the outdoor coil. Ice blocks airflow, so the heat pump has a defrost control that runs the system briefly in reverse, sending hot refrigerant to the outdoor coil to melt the frost. During defrost:

  • The outdoor fan usually stops.
  • You hear a whoosh when the reversing valve shifts, and again when it shifts back.
  • Steam rises off the outdoor unit. This scares people, but it is water vapor, not smoke.
  • Water runs out of the bottom of the unit. ENERGY STAR notes that this melt water can form icy patches, so do not place the outdoor unit where it drips onto a walkway or driveway.
  • Backup heat strips may turn on indoors so you do not feel cold air. Florida's Energy Code specifically allows backup heat to run during defrost.

Defrost usually lasts a few minutes and repeats as needed. Light frost that comes and goes is normal. A solid block of ice, ice on the top of the unit that never clears, or a coil that stays white all day means the defrost control, a sensor, low refrigerant or a stuck fan needs attention. Gutter water dripping onto the unit can also cause heavy icing; fixing the gutter can solve it.

Do not chip ice off the coil with a tool, which can puncture the thin fins and tubes. If the unit is iced solid, switch the thermostat to emergency heat and call for service. You can rinse light ice away with lukewarm (not boiling) water from a hose if the power to the unit is off.

What do Aux heat and Emergency heat mean?

Most heat pumps in Texas and Florida have electric resistance heat strips in the indoor air handler. These work like a giant toaster: simple, reliable, and expensive to run. The thermostat uses them in two ways.

SettingWhat it doesWhen it is normal
Aux heat (auxiliary)The thermostat turns on heat strips automatically to help the heat pumpDuring defrost, on very cold nights, or when you raise the setting several degrees at once
Em heat (emergency)You manually turn off the heat pump and heat only with strips (or a furnace)When the outdoor unit is broken, iced solid or damaged

Florida's Energy Code requires heat pumps with electric backup to have controls that keep the strips off except when the heat pump cannot meet the thermostat setting, during defrost, or when the heat pump or thermostat malfunctions. That is why a modern thermostat shows "Aux" only some of the time.

Why is my emergency heat on?

  • Someone switched the thermostat to Em Heat and forgot to switch it back. This is the most common reason for a shocking winter bill.
  • The thermostat was wired or set up wrong after a replacement, so it calls for strips too often.
  • The outdoor unit has failed and the thermostat is showing an alert.
  • Aux heat comes on every time you bump the temperature up several degrees. Many thermostats bring on strips when the gap between the setting and the room is large.

If Aux heat runs all the time even on a 50 degree day, have the heat pump checked. It may be low on refrigerant, or the outdoor unit may not be running at all.

Why are my winter electric bills so high in Florida and Texas?

Most Florida homes heat with electricity, either a heat pump or heat strips. When a cold front pushes temperatures into the 30s in Orlando, Tampa or Jacksonville, three things drive the bill up:

  1. Heat strips run more. Resistance heat turns each unit of electricity into one unit of heat. A heat pump moves several units of heat for each unit of electricity it uses, which is why ENERGY STAR says a heat pump is more efficient than a furnace or boiler even in winter. Every hour the strips run instead of the compressor costs you more.
  2. Setbacks backfire. ENERGY STAR advises heat pump owners not to turn the thermostat down at night or when away. When you turn it back up, the thermostat may call for heat strips to catch up, and you lose the savings.
  3. The house leaks. Leaky attic ducts and thin insulation lose heat just as they gain heat in summer. ENERGY STAR estimates that 20% to 30% of the air moving through a typical home's ducts is lost to leaks and poor connections. See our duct guide.

How to cut a cold-snap bill

  • Pick a steady temperature and leave it. Florida's Energy Code sets the factory heating default for new programmable thermostats at no higher than 70 degrees F, which is a sensible starting point. Every degree lower saves energy.
  • Make sure the thermostat is on Heat, not Em Heat and not Auto. ENERGY STAR recommends avoiding Auto mode on heat pumps so the system does not flip between heating and cooling on mild days.
  • Raise the temperature 1 or 2 degrees at a time, not 6 at once.
  • Replace a dirty filter. ENERGY STAR says airflow problems can cut efficiency by up to 15%.
  • Close blinds at night and open south-facing ones on sunny days.
  • Use a smart thermostat's heat pump settings, such as an aux heat lockout temperature, if your installer set it up. See our thermostat guide.

If your system has heat strips only and no heat pump (common in older Florida condos and apartments), a cold week will always cost more. When it is time to replace the system, a heat pump is the efficient choice. Florida's Energy Code also requires electric resistance furnaces in new installs to be sized within 4 kW of the calculated design load, so oversized strip heaters are not supposed to go in. For high bills in general, see our high electric bill guide.

Why won't my gas furnace ignite?

Furnaces are the main heating equipment in 61% of Texas homes, per EIA, and many of them burn natural gas, especially in Dallas-Fort Worth, Austin, San Antonio and the Panhandle. A modern gas furnace lights in a set order: the thermostat calls for heat, the inducer fan starts to clear the vent, a pressure switch confirms the vent is clear, the ignitor heats or sparks, the gas valve opens, burners light, the flame sensor proves the flame, and finally the main blower comes on. A failure at any step stops the sequence.

Common causes, in order of likelihood

  1. Thermostat or power. Dead thermostat batteries, the thermostat on Cool, a furnace power switch (it looks like a light switch near the unit) turned off, or a tripped breaker.
  2. Dirty filter. A clogged filter can overheat the furnace and trip a limit switch, so it lights, runs a few minutes and shuts off.
  3. Dirty flame sensor. The burners light for a few seconds, then shut off, and the furnace tries again three times before locking out. A technician can clean or replace the sensor, which is a small, routine fix.
  4. Cracked hot surface ignitor. You hear the inducer fan, but you never see the ignitor glow and the burners never light. Ignitors wear out.
  5. Pressure switch or blocked vent. A bird nest, ice on a side-wall vent, or a clogged condensate drain on a high-efficiency furnace keeps the pressure switch from closing.
  6. Gas supply. A closed gas valve, an unpaid gas bill or a utility outage.
  7. Control board lockout. After several failed tries, the board stops trying. Turning the power off for a minute resets it, but if it locks out again, the underlying problem is still there.

Most furnaces have a small light on the control board that blinks a code. Look through the window in the lower panel and count the blinks, then match it to the chart on the inside of the door. Telling the technician the code saves time.

Safety first: if you smell gas, leave the house and call the gas utility from outside. If the CO alarm sounds, get everyone out and call 911. Do not keep resetting a furnace that keeps shutting off, because the safety controls may be preventing a real hazard. Read our furnace safety and carbon monoxide guide before winter.

Why does my heater smell like burning dust?

The first time you turn on heat each fall, dust that settled on the heat strips or the furnace heat exchanger over the summer burns off. In Texas and Florida, where heat may not run for eight or nine months, that layer can be thick. A dry, dusty burning smell that fades within an hour or so is normal.

Call for service if the smell is sharp, like hot plastic or wiring, if it keeps going after the first hour, if you see smoke from a vent, or if a breaker trips. Something may have fallen onto the heat strips, or a motor may be overheating. A rotten egg smell around a gas furnace means a possible gas leak. Leave and call the gas utility.

How do I prepare my HVAC for a Texas freeze?

Texas remembers February 2021. The Texas Department of State Health Services confirmed 246 deaths tied to that winter storm across 77 counties. Most, 158, were from hypothermia, and 107 of those victims were 60 or older. Another 19 deaths were from carbon monoxide poisoning caused by generators, grills, heaters, vehicles run in enclosed spaces and ice blocking vents on gas heating equipment. Preparing your heating system and your household is not optional when a hard freeze is forecast.

Before the freeze (a week to a few days ahead)

  • Run the heat for a full cycle to make sure it works, before every company in town is booked.
  • Replace the filter.
  • Clear leaves, mulch and debris around the outdoor heat pump unit so it can breathe and drain.
  • Check that furnace and water heater vent caps outside are clear.
  • Test CO and smoke alarms, and put fresh batteries in the thermostat.
  • Know where your breaker panel, the outdoor disconnect and the gas shutoff are.
  • Plan safe backup heat in case the power goes out. Never use a gas oven, charcoal grill or camp stove indoors. CDC warns against all three.

During the freeze

  • Leave the thermostat at a steady setting. Do not crank it up 10 degrees, which only brings on heat strips and strains the grid.
  • Expect the heat pump to run constantly and to defrost often. That is normal.
  • If the outdoor unit ices solid and stops heating, switch to Em Heat and call for service.
  • If the power goes out, run any generator outdoors, more than 20 feet from windows, doors and vents, as CDC advises. Our generator guide covers sizing and transfer switches.
  • When the power comes back after an outage, give the system a few minutes before calling for heat so the grid and your equipment are not hit with a surge all at once.

Should I cover my heat pump in a freeze?

No, not while it is running. A heat pump must pull outdoor air across its coil and drain defrost water. Wrapping it in a tarp or blanket blocks airflow, traps ice, and can damage the fan and coil. Covers made for AC units are meant for the off season on cooling-only condensers, not for a heat pump you are using. If ice or snow builds on top of the unit, gently brush it off by hand with power off. Keep the area around the base clear so melt water drains away.

Older adults and vulnerable family

Because older adults made up most hypothermia deaths in 2021, check on elderly neighbors and relatives during a freeze. If their heat fails and repairs cannot happen quickly, move them to a family member's home or a warming center. Dial 2-1-1 to ask about local warming centers. Our companion guide on heat safety for seniors covers the summer side of the same problem.

Florida cold snaps: what is different

True freezes are rare in South Florida. NOAA's 2025 State Climate Summary notes that Miami International Airport has dropped to 32 degrees F or lower only 6 times since 1948, and not once since 1989. North Florida is another story: the state's record low, minus 2 degrees F, was set in Tallahassee in 1899, and Jacksonville and the Panhandle see freezing nights most winters.

  • South Florida (Miami, Fort Lauderdale): Heat runs only a handful of days a year. The main risks are the first-fire dust smell and an Em Heat switch left on. Many condos have heat strips only.
  • Central Florida (Tampa, Orlando): Cold fronts bring nights in the 30s. Heat pumps work fine, but strips run more, so bills jump.
  • North Florida (Jacksonville, Tallahassee, Gainesville): Hard freezes happen. Follow the Texas freeze checklist above. Gas furnaces are more common here.

Florida renters: Fla. Stat. 83.51 requires landlords of units other than single-family homes and duplexes to make reasonable provision for functioning heat during winter, unless otherwise agreed in writing, and all landlords must follow applicable building, housing and health codes. Put repair requests in writing. See our Florida landlord guide.

Texas renters: Texas Property Code 92.052 requires a landlord to make a diligent effort to repair a condition that materially affects an ordinary tenant's physical health or safety after proper notice. No heat during a freeze can meet that standard. The law presumes 7 days is a reasonable repair time, though severity can shorten it. See our Texas landlord guide.

What temperature should I set my heat in winter?

There is no single legal or medical number for every home, but these guidelines are sourced and practical:

  • Florida's Energy Code requires new programmable thermostats to ship with a heating set point no higher than 70 degrees F. That is a reasonable comfort ceiling for most families.
  • For heat pumps, ENERGY STAR says pick a comfortable temperature and keep it there, because heat pumps do not save energy by setting back when you are away or asleep.
  • For gas furnaces, modest setbacks at night are fine because a furnace does not have expensive backup strips.
  • If you have an older adult, infant or someone with a medical condition at home, keep the house warmer and steady. Do not let the house get cold to save money.
  • If you are leaving a home vacant in winter, do not turn the heat off entirely in North Texas or North Florida, where pipes can freeze. See our vacant home guide.

How much does heat pump or furnace repair cost?

No verified, dated study publishes heating repair prices city by city for Texas or Florida. The closest dated reference is Fixr's national heat pump repair guide, updated January 21, 2026, which puts the average heat pump repair at about $400, with most jobs between $150 and $650. These are national figures, so treat them as a starting point, not a Texas or Florida price list.

Heat pump repair (Fixr, Jan. 2026, national)Typical range
Standard service call$75 to $250
Thermostat replacement$85 to $300
Capacitor replacement$100 to $400
Refrigerant recharge$100 to $600
Circuit board replacement (includes defrost and control boards)$150 to $700
Refrigerant leak repair$200 to $1,500
Blower motor replacement$300 to $1,000
Reversing valve replacement$350 to $700
Compressor replacement$800 to $2,500
Condenser (outdoor unit) replacement$1,000 to $4,000
Air handler replacement$1,500 to $3,500

Repair prices depend on the part, the refrigerant, after-hours rates and the company. Small fixes, such as cleaning a flame sensor or replacing a capacitor, are usually far cheaper than repairs that require opening the refrigerant circuit, such as a reversing valve or compressor. We did not find a dated furnace repair price list we could load, so we do not quote furnace part prices here. Always ask for a written quote that lists parts, labor and refrigerant separately. Our repair cost guide explains how to read a quote.

For replacement, Trane's 2026 cost guide, a manufacturer estimate rather than an independent study, puts installed heat pump replacement at $8,313 to $10,289 for single-stage, $9,921 to $12,648 for multi-stage and $12,778 to $15,608 for variable-speed systems. It puts an 80% AFUE gas furnace at $5,093 to $6,386 and a 96% AFUE furnace at $6,630 to $8,390. Trane says furnaces and heat pumps are expected to last about 15 to 20 years when properly installed and maintained.

Things to know before replacing:

  • The federal 25C home improvement tax credit ended for equipment placed in service after December 31, 2025. There is no federal 25C credit for a 2026 heat pump or furnace install. See our 25C guide.
  • Utility rebates still exist. CPS Energy in San Antonio requires heat pumps to reach at least 7.5 HSPF2 and verifies efficiency with an AHRI certificate. Austin Energy offers heat pump rebates by tier but excludes AC systems with electric resistance heating. See Texas rebates and Florida rebates.
  • The federal minimum for a new split-system heat pump is 14.3 SEER2 and 7.5 HSPF2 (HSPF2 is the heating efficiency rating; higher is better).
  • Equipment made before January 1, 2025 with R-410A refrigerant can still be installed with no deadline, after EPA's May 2026 rule removed the earlier cutoff. New equipment uses R-454B or R-32.

For help deciding, see repair or replace and heat pump vs gas furnace.

Preventing winter breakdowns

ENERGY STAR recommends a contractor check the heating system each fall and the cooling system each spring, and suggests planning check-ups around the clock changes. In Texas and Florida, where the heat pump also does your cooling, one well-timed visit can cover both. Ask the technician to:

  • Test heating mode, the reversing valve and the defrost control.
  • Check that heat strips work and that each strip's current draw is normal.
  • Confirm the thermostat's aux heat settings.
  • Inspect the gas furnace burners, flame sensor, ignitor, vent and heat exchanger.
  • Check refrigerant pressures and look for oily spots that suggest a leak.
  • Clean the outdoor coil and check the condensate drain.

ENERGY STAR also recommends checking filters monthly. For the full list, see our maintenance checklist. Before hiring, verify the license: TDLR in Texas, DBPR in Florida. See choosing a contractor.

How to choose a provider

  • Set the thermostat to Heat (not Cool, Auto or Em Heat) and the fan to Auto.
  • Replace the filter before the first cold night.
  • Check the breaker and outdoor disconnect if the outdoor unit is silent.
  • Clear a couple of feet around the outdoor heat pump; never wrap it while it is running.
  • Wait several minutes if you see steam: it is probably defrost.
  • Switch to Em Heat only if the outdoor unit is iced solid or broken, then call for service.
  • Read and write down the furnace's blinking error code before calling.
  • Raise the temperature 1 to 2 degrees at a time to avoid heat strip spikes.
  • Check outdoor furnace and water heater vents for ice and nests before a freeze.
  • Test CO and smoke alarms before heating season.
  • Check on elderly neighbors during a freeze; call 2-1-1 for warming centers.
  • Schedule a fall heating check with a licensed contractor.

Related ac and heating guides

AC and heating by state and city

Questions people ask

Why is my heat pump blowing cold air?

Check the thermostat first: it should be on Heat with the fan on Auto, not On. If the air turns cool for a few minutes and you see steam outside, the unit is defrosting, which is normal. Heat pump air also feels cooler than furnace air. If the air stays cold, check the breaker and outdoor disconnect, replace a dirty filter and clear debris from the outdoor unit. Persistent cold air can mean a stuck reversing valve, low refrigerant or a failed defrost control, all jobs for a technician.

Why does my heat pump make a whooshing noise and steam?

That is almost always the defrost cycle. In cold, damp weather, frost forms on the outdoor coil. The heat pump briefly reverses to melt it, which makes a whoosh as the valve shifts, stops the outdoor fan and sends up a cloud of steam. Defrost usually lasts a few minutes. It is a problem only if the coil stays iced solid, the cycle never ends, or the unit makes grinding or banging sounds.

Is it normal for my heat pump to run constantly when it is 25 degrees?

Yes. At 25 degrees F, the house loses heat fast and the heat pump produces less heat per hour than it does in mild weather, so it may run nearly nonstop. That is what it is designed to do. Your backup heat strips may also cycle on. The concern is if the house temperature keeps dropping, the outdoor unit ices over completely, or the heat pump runs constantly on mild 50 degree days.

Why is my emergency heat on?

Usually someone switched the thermostat to Em Heat and forgot to switch it back, or a new thermostat was set up wrong. Some thermostats also show Aux heat whenever you raise the setting by several degrees or during defrost, which is normal. If the thermostat turns on emergency heat by itself and shows an alert, the outdoor heat pump may have failed. Running on emergency heat for long periods costs much more, so get the heat pump checked.

Should I cover my heat pump in a freeze?

No. A heat pump that is heating your home must pull air across its outdoor coil and drain defrost water. A tarp or blanket blocks airflow, traps ice and can damage the fan. Instead, clear leaves and debris, keep the base clear so water drains, fix gutters that drip onto it, and brush heavy snow or ice off the top by hand with the power off. Covers are meant for cooling-only condensers in the off season.

Why won't my furnace ignite?

Check the simple things first: thermostat batteries and mode, the furnace power switch, the breaker, and the gas valve. Then look at the blinking light on the control board and match the code to the chart inside the panel. The most common failures are a dirty flame sensor, which makes burners light and shut off, a cracked hot surface ignitor, and a pressure switch that will not close because the vent or condensate drain is blocked. Call a technician if it keeps locking out.

Why are my electric bills so high in winter in Florida?

Most Florida homes heat with electricity. When a cold front arrives, heat strips run more, and they use far more power than the heat pump for the same heat. Setting the thermostat back at night and then raising it several degrees in the morning also triggers the strips. Keep a steady setting, make sure the thermostat is not on Em Heat, change dirty filters, and have the heat pump checked if Aux heat runs constantly.

How do I prepare my HVAC for a Texas freeze?

A few days ahead, run a full heating cycle to make sure everything works, replace the filter, clear the outdoor unit, check that furnace and water heater vents are open, and test CO alarms. During the freeze, hold a steady temperature and expect long run times and frequent defrost. Plan safe backup heat in case of an outage, and never use a gas oven, grill or generator indoors. Check on older relatives and neighbors.

What temperature should I set my heat in winter?

Florida's Energy Code requires new programmable thermostats to ship with a heating setting no higher than 70 degrees F, which is a sensible starting point. With a heat pump, ENERGY STAR says to pick a comfortable temperature and leave it, because setbacks can trigger costly heat strips. With a gas furnace, small nighttime setbacks are fine. Keep the home warmer and steady if an older adult, infant or someone with a health condition lives there.

Can my landlord leave me without heat in winter?

In Texas, a landlord must make a diligent effort to repair a condition that materially affects an ordinary tenant's health or safety after proper notice, and the law presumes 7 days is a reasonable repair time. In Florida, landlords of units other than single-family homes and duplexes must make reasonable provision for functioning heat in winter unless otherwise agreed in writing. Give written notice and keep copies. This is general information, not legal advice; contact legal aid for your case.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration