Local Guide · Electricians

How do you choose and install recessed and LED lighting the right way?

IC and airtight ratings, cans vs. canless wafer lights vs. retrofit kits, Texas and Florida attic heat, dimmer compatibility, why LEDs buzz or flicker, shower and closet rules, layout, permits, licensing and what really drives the cost of a lighting upgrade.

Use recessed lights rated Type IC wherever insulation can touch them, and choose airtight (AT) models under an attic so cooled air does not leak out. Non-IC housings need at least 3 inches of clearance to insulation. Convert old cans only with a listed LED retrofit kit for that housing. Pick dimmers from the light maker's compatibility list to avoid flicker and buzz. Showers need damp or wet-rated trims. New circuits and fixtures are licensed electrical work in Texas and Florida.

Key facts

  • ENERGY STAR says recessed downlights touching insulation should be Type IC, and non-IC models usually require at least 3 inches of clearance to the nearest insulation.
  • ENERGY STAR recommends Type AT (airtight) downlights below an unconditioned attic so paid-for heated or cooled air does not escape.
  • IAEI notes the NEC requires non-IC recessed housings to have 1/2 inch of space from combustibles and 3 inches from insulation, and requires recessed luminaires to have thermal protection.
  • ENERGY STAR certified downlights use 90 percent less energy than traditional incandescent models and come with at least a three-year warranty.
  • LED lighting products produce light up to 90 percent more efficiently than incandescent bulbs, and LED life is rated to the point where output drops by 30 percent (ENERGY STAR).
  • ENERGY STAR says thermal management is generally the single most important factor in an LED's performance: the hotter it runs, the faster light degrades.
  • ENERGY STAR ended its label for most light fixtures but kept it for high-performing recessed downlights (Downlights Version 1.0, effective Nov. 16, 2023).
  • A luminaire converted with a listed retrofit kit installed per its instructions is not considered reconditioned under the 2023 NEC (IAEI).
  • In tub and shower zones, luminaires within the tub or shower outline up to 8 feet high must be marked for damp locations, or wet where subject to spray (IAEI on NEC 410.10(D)).
  • Push-in terminals on snap switches are limited to 14 AWG copper on 15-amp circuits unless the device is listed and marked otherwise (NEC 404.14(D), per IAEI).

Your recessed and LED options at a glance

Recessed lights (also called can lights, pot lights or downlights) sit inside the ceiling so only the trim shows. Today there are three main ways to get them:

OptionWhat it isGood fit forWatch out for
New-construction housing (can)A metal housing nailed to joists before drywall, with a separate trim or LED moduleNew builds, gut remodels, open ceilingsIC and airtight ratings; needs ceiling access
Remodel housing (can)A housing that installs through a hole cut in an existing ceiling, held by clipsAdding lights to finished ceilingsFit around joists, ducts and insulation
Canless (wafer) LED fixtureA thin LED panel with a small remote junction or driver box, installed through the holeShallow ceilings, retrofits, quick installsMust be listed for the use; check IC and airtight markings and the driver box location
LED retrofit kitAn LED module and trim that installs into an existing canUpgrading old incandescent cansMust be a listed kit compatible with that housing
Screw-in LED lampAn LED bulb shaped for recessed cans (BR or PAR shape)The cheapest upgrade with no wiring changeHeat inside the can shortens LED life; check the can's lamp rating

Whatever you pick, the code requires installation according to the product's listing and instructions (NEC 110.3(B)), which is why the labels on the housing and kit matter more than the box art.

Code edition: Texas enforces the 2026 NEC statewide since September 1, 2026. Florida enforces the 2020 NEC until its 9th Edition Building Code, based on the 2023 NEC, takes effect (December 31, 2026 per the Florida Building Commission; Tampa says January 1, 2027). The lighting rules on this page are similar across those editions unless noted.

What is an IC-rated can light, and what does airtight mean?

IC vs. non-IC

IC stands for insulation contact. An IC-rated housing is designed to be buried in or touched by thermal insulation without overheating. A non-IC housing is not.

  • Type IC: may be in direct contact with insulation and combustible material. ENERGY STAR says if insulation will touch your new downlights, buy models rated Type IC.
  • Non-IC: must be kept away from insulation. IAEI's inspection article explains that the NEC requires at least 1/2 inch of space from recessed parts to combustibles (not counting the support or trim) and at least 3 inches to any insulation. ENERGY STAR gives the same 3-inch figure for non-IC models.

The 3-inch clearance is hard to keep in real attics. IAEI points out that blown-in insulation goes everywhere, and batts can fall onto fixtures over time. That is why IC-rated housings are the right choice in nearly every insulated ceiling. IAEI also notes that 6 and 7 inch cans are usually IC rated, while small 4-inch cans in alcoves are more often non-IC, so check the label on small fixtures.

Airtight (AT)

An airtight-rated (Type AT) recessed light limits how much air leaks through the fixture into the attic. An ordinary can is a hole in your ceiling. In summer, cooled air leaks up and hot attic air can be pulled down; in winter the reverse happens. ENERGY STAR recommends Type AT models when the downlights are installed below an unconditioned attic, to keep the air you paid to heat or cool in your living space.

Look for both markings, often printed together, such as IC and AT, on the housing label. Your local energy code may also have air-sealing rules for fixtures in the insulated ceiling, so ask your building department what it will check at inspection.

Can recessed lights go in an insulated ceiling in a Texas or Florida attic?

Yes, if they are IC-rated, and ideally airtight. Texas and Florida attics are a tough environment for lighting. Many homes in both states have ductwork and insulation in the attic directly above the living space, and summer attics get far hotter than the rooms below. That heat affects recessed lighting in three ways:

  1. LED life. ENERGY STAR says thermal management is generally the single most important factor in an LED's performance over its lifetime: the higher the operating temperature, the faster the light degrades and the shorter the useful life. An LED module sealed in a hot can under insulation runs hotter than one in an open fixture. ENERGY STAR certified LED products are tested to manage heat so their output holds through their rated life.
  2. Thermal protector trips. IAEI explains that recessed luminaires must have a thermal protection device that disconnects the lamp if the temperature limit is exceeded. If a light shuts off and comes back on by itself, the lamp may be oversized for the housing, the wrong trim may be installed, or the socket bracket may be set wrong. That cycling is a warning, not a nuisance.
  3. Energy loss. Leaky cans pull hot, humid attic air into the house in summer, which adds to air-conditioning load and can bring moisture. Airtight-rated fixtures, sealed per the manufacturer's instructions, limit that.

Practical tips for hot attics

  • Choose IC and AT rated housings or canless fixtures with those markings.
  • Prefer integrated LED modules or kits designed for the housing over screw-in bulbs sealed into old cans.
  • Keep insulation in full contact only with IC-rated fixtures; pull insulation back the required distance from any non-IC housing, or replace the housing.
  • Do not cover a can with a homemade box or foam unless the fixture's instructions allow it. Some manufacturers sell listed covers designed for their housings.
  • For canless wafers, place the driver or junction box where the instructions say, and keep it accessible.

Wafer lights vs. cans vs. retrofit kits: which should I choose?

Canless wafer lights

Canless LED fixtures, often called wafer lights, have become popular because they install through a small hole with spring clips and need only a few inches of space above the ceiling. Each comes with a small junction box or driver box that sits beside the fixture in the ceiling cavity. Advantages: quick installation, shallow depth that clears joists and ducts, and many models are rated for insulation contact and airtight. Limits: the light and driver are a single product, so when the LED fails you replace the whole fixture; color and dimming quality vary by brand; and the junction box must stay accessible through the fixture opening as the instructions describe.

Cans with LED modules

A housing with a separate LED module or trim lets you change the light later without touching the housing. It is the traditional choice in new construction. Choose IC and AT housings, and pick modules listed for that housing.

LED retrofit kits for existing cans

Many homes have old incandescent cans. Retrofit kits replace the bulb and trim with an LED module that plugs into the socket or wires in. UL explains that when a listed luminaire is modified in the field, it cannot confirm the product still meets its safety requirements unless the change is evaluated, and that the practical alternative is a retrofit kit specifically investigated and certified for installation in that type of luminaire. UL-classified kits carry a mark stating they are for use only with specific luminaire types, in accordance with the kit's instructions, and a converted luminaire gets a label showing it has been modified.

The NEC backs this up. IAEI's 2025 summary says retrofit kits must be listed and installed exactly per their instructions (410.6 and 110.3(B)), and that a luminaire retrofitted that way is not considered reconditioned under the 2023 NEC.

Screw-in LED lamps

Screw-in LED reflector lamps are the easiest upgrade, but they leave the old trim, socket and housing in place, and heat builds up inside a closed can. Use lamps rated for enclosed or recessed fixtures where the packaging says so, and replace old non-IC cans buried in insulation rather than relying on cooler lamps to make them safe.

QuestionCanless waferCan plus moduleRetrofit kit
Existing old cans?Remove cans or install elsewhereReplace housingYes, reuse housing
Shallow ceiling space?Good fitMay not fitUses existing can
Future replacementWhole fixtureModule onlyKit only
Insulation contactIf marked ICIf housing is ICDepends on the old housing's rating

Are can lights a fire hazard?

A correctly rated and installed recessed light is not a fire hazard. Problems come from mismatches. IAEI's inspector writes that recessed lighting is one of the most important residential inspection items because the housing traps heat at the top of the room inside a concealed space, and nobody can easily see what is touching it. The main risk patterns:

  • A non-IC housing buried in insulation. This is the classic problem, especially with older incandescent cans after someone adds blown-in insulation.
  • An oversized lamp. A 100-watt incandescent in a can labeled for 60 watts overheats the housing.
  • The wrong trim for the housing, which changes how heat escapes.
  • Combustibles too close to a non-IC housing, such as stored boxes in an attic or framing.
  • Damaged wiring in old fixtures where heat has made insulation brittle.

Warning signs: lights that switch off and on by themselves (a thermal protector tripping), discolored or brittle trim, a burning smell near a fixture, or scorched insulation seen from the attic. Turn the light off and have an electrician look. See burning smell from electrical.

For context, the U.S. Fire Administration estimates 23,700 residential building electrical malfunction fires in 2023, with 305 deaths. USFA does not break these out by lighting type, but keeping heat-producing equipment correctly rated is part of preventing them. See electrical fire prevention.

LED lighting lowers the risk because LEDs produce far less heat for the same light. ENERGY STAR notes LEDs emit light in a specific direction and use heat sinks, unlike incandescent bulbs, which emit light and heat in all directions. LEDs still produce heat at the driver and module, so ratings still matter.

LED basics: lumens, watts, color and lifetime

Brightness is lumens, not watts

Watts measure power use; lumens measure light. ENERGY STAR's minimum lumen levels for standard bulbs give a handy comparison: a 60-watt equivalent should give about 800 lumens and a 100-watt equivalent about 1,600 lumens. When you compare LED downlights, compare lumens, and look at how much of that light reaches the floor or counter (a narrow beam puts more on the surface below; a wide beam spreads it).

Efficiency

ENERGY STAR says LED lighting produces light up to 90 percent more efficiently than incandescent, and ENERGY STAR certified downlights use 90 percent less energy than traditional models using incandescent bulbs. ENERGY STAR estimates that if all downlights and retrofit kits sold in the U.S. were certified, energy cost savings would exceed $1 billion a year.

Color temperature

Color appearance, or correlated color temperature, is measured in kelvins (K). ENERGY STAR's guidance:

KelvinLooks likeCommon uses
2200 to 3000KWarm, like incandescentLiving rooms, bedrooms, dining
3500 to 4100KWhiterKitchens, baths, laundry, workspaces
5000 to 6500KBluish whiteGarages, workshops, task areas

Some downlights let you switch color with a switch on the fixture or an app, and some are designed to get warmer as they dim. Keep the same color temperature within a room so fixtures match.

Lifetime

LEDs rarely burn out suddenly. ENERGY STAR explains they experience lumen depreciation, dimming slowly over time, and their rated lifetime is the point at which output is predicted to drop by 30 percent. Heat speeds this up. ENERGY STAR certified downlights carry a manufacturer warranty of at least three years.

ENERGY STAR ended its label for most light fixtures because efficient LED lighting is now the norm, but kept it for high-performing recessed downlights under its Downlights Version 1.0 specification, effective November 16, 2023. The label is still a useful shortcut when shopping for downlights.

How many recessed lights do I need per room?

There is no code formula for how many recessed lights a room needs. The NEC requires at least one wall-controlled lighting outlet in habitable rooms, kitchens, bathrooms, hallways, stairways, garages and other listed spaces (210.70), and the 2023 NEC added laundry areas. Beyond that, layout is a design choice. A practical approach:

  1. Decide what the light is for. Ambient light fills the room. Task light falls on counters, desks and stoves. Accent light highlights art or walls. Recessed lights are good at ambient and task light, less good at making a room feel warm by themselves.
  2. Work from the surfaces. In kitchens, center lights over the front edge of the counter so you do not cast shadows on your work. Over islands, space them along the island's length.
  3. Use a starting grid, then adjust. A common designer rule of thumb, not a code rule, is to space ambient downlights roughly half the ceiling height apart and about half that distance from walls. Wider beams and brighter fixtures allow wider spacing.
  4. Avoid a runway look. Rows of lights down the center of a room light the floor and leave walls dark. Pulling lights toward the walls, or washing a wall with adjustable trims, makes rooms feel larger.
  5. Layer and dim. Add dimmers and separate switching for zones so you can lower light at night.

Check above the ceiling before finalizing positions. Joists, ducts, plumbing, trusses and, in Florida condos, concrete slabs will move some lights. A good installer marks the layout and confirms clear spots before cutting.

What dimmer do I need for LED recessed lights?

The dimmer and the LED driver have to work together. Not every LED light works well with every dimmer. ENERGY STAR's advice:

  • If you are installing new downlights on an existing dimmer, check the dimmer manufacturer's website for the lights it recommends.
  • ENERGY STAR certified lights maintain a list of compatible dimmers. If you are installing a new dimmer, check the website on the downlight package for recommended dimmers.
  • If you do not get a good match, replace the dimmer or return the lights and try a different model.

What incompatibility looks like

  • Flicker or shimmer, especially at low settings
  • Lights that will not dim all the way down, or drop out suddenly
  • Lights that will not turn on at low settings, or glow faintly when off
  • Buzzing from the dimmer or the fixtures
  • A dimmer that runs hot

Tips that prevent most problems

  • Use the same brand and model of light on one dimmer.
  • Stay within the dimmer's rated LED load, shown on the dimmer or in its instructions.
  • Use the dimmer's low-end trim adjustment if it has one.
  • Fan motors need a fan control, not a light dimmer. ENERGY STAR warns a conventional dimmer can make a fan motor hum. See ceiling fan installation.

Smart dimmers

Many smart dimmers need a neutral wire in the switch box. NEC 404.2(C) generally requires a neutral at switch locations controlling lighting loads, with limited exceptions, but older homes often lack one. IAEI also notes 404.14(D) limits push-in (back-stab) terminals on snap switches to 14 AWG copper on 15-amp circuits unless the device is listed and marked otherwise, and 404.16 bans reconditioned switches and dimmers: a device damaged by fire, water or smoke must be replaced. The 2026 NEC, now enforced in Texas, moves wall switches and dimmers to a new Part III of Article 406 with largely the same technical rules. See smart home electrical.

Why do my LED recessed lights buzz or flicker?

Work through causes from simplest to most serious:

SymptomLikely causesWhat to do
Flicker only when dimmedDimmer not compatible, too many or too few lights on the dimmer, low-end trim set wrongCheck the compatibility list; adjust trim; change dimmer
Buzz from dimmer or fixturesIncompatible dimmer, cheap driver, loose trimTry a compatible dimmer; tighten trims; replace noisy units
Glow when switched offSmall leakage through a dimmer or smart switch without a neutral, or a lighted switchUse a switch designed for LEDs or one that uses a neutral
One light flickers, others fineFailing LED module or driver, loose connection, heatReplace the module or fixture; check connection
Light shuts off and on by itselfThermal protector tripping from heatCheck lamp and trim ratings and insulation clearance; replace mismatched parts
Many lights flicker when the AC or a big appliance startsVoltage dip from large motor loads, a loose connection in the panel or service, or a utility problemCall an electrician; report widespread dimming to your utility
Some lights very bright, others dimPossible lost neutralTurn off sensitive equipment and call an electrician and the utility now

Flicker on many circuits at once is a wiring or utility issue, not a bulb issue. See flickering and dimming lights.

Can recessed lights go in a shower?

Yes, with the right rating. NEC 410.10(D) sets the bathtub and shower zone: the space within the outside dimensions of the tub or shower up to 8 feet above the tub rim or shower threshold. IAEI's 2025 summary of the rules:

  • Luminaires within that zone must be marked for damp locations, or for wet locations where subject to shower spray.
  • No part of a cord-connected, chain, pendant or track luminaire, and no ceiling fan with a light kit, may be within 3 feet horizontally and 8 feet vertically of the tub rim or shower threshold.

IAEI's inspector describes a common shower recessed light: a trim listed for damp locations because of steam, with a firm gasket around the trim ring to keep moisture out of the fixture. Thin, soft foam is not enough. Where spray reaches the fixture, such as in an open walk-in shower with a rain head, use a wet-rated trim or fixture.

Check whether a fixture's damp or wet rating depends on using a specific lensed trim. The rating belongs to the housing and trim combination listed together, so do not swap trims from another product line.

Follow the fixture instructions on any GFCI requirement for the light itself. If a bathroom light includes a built-in receptacle, that receptacle must be GFCI protected (210.8(A)).

What about closets, kitchens and under-cabinet lighting?

Closets

Clothes closets are a common inspection failure. NEC 410.16 defines the closet storage space and limits fixtures in it by type and clearance. IAEI explains that surface-mounted fluorescent or LED fixtures listed for installation within the closet storage space can be used where labeled, while open lamps and pendants in the storage space are prohibited. Do not assume a low-heat LED is allowed without that specific listing. Recessed lights in closets must keep the required clearance from the storage area.

Kitchens

Kitchens usually combine recessed ambient light with task lighting at counters. The NEC requires a wall-switched lighting outlet. Remember that 2023 NEC kitchens require AFCI protection on 15 and 20 amp, 120-volt circuits, so new lighting circuits in kitchens will typically be AFCI protected (210.12(B)).

Under-cabinet lighting

TypeHow it connectsWho can install
Plug-in LED strips or barsCord to a countertop receptacleAnyone; keep cords tidy and away from sinks and heat
Low-voltage tape or puck lights with a plug-in driverClass 2 driver plugs into a receptacle inside a cabinetHomeowner in most cases
Hardwired line-voltage barsWired to a branch circuit through a box or the fixture's wiring compartmentLicensed electrician, or an owner-occupant where allowed
Hardwired low-voltage with a hidden driverDriver wired to line voltage; Class 2 wiring to lightsElectrician for the line-voltage connection

In Texas, the licensing law exempts Class 1, 2 and 3 power-limited circuits (Occ. Code 1305.003(a)(12)), but connecting the driver to a line-voltage circuit is electrical work. In Florida, hardwired line-voltage work is electrical contracting under Part II of chapter 489 unless the owner-builder exemption applies.

Do recessed lights need a permit, and who can install them?

Permits

Adding new recessed lights usually means new boxes, new cable and often a new switch or circuit, which most Texas cities and Florida counties treat as permitted electrical work. Replacing a fixture with another on the same box, or installing a listed retrofit kit in an existing can, is often treated as a repair. Rules vary, so call your building department. In Florida, if a direct contract for the work exceeds $5,000, the permit office must require a recorded notice of commencement before the first inspection (s. 713.135(1)(e)).

Texas licensing

Under Occupations Code chapter 1305, a person may not perform electrical work for others without a TDLR license. The owner who lives in the home is exempt from the state law unless a city ordinance regulates the work. A handyman or remodeler without an electrical license may install a plug-in fixture but may not run new wiring for pay. Verify licenses at TDLR's license search. See Texas electrician licensing.

Florida licensing

Electrical contractors are licensed through the Electrical Contractors' Licensing Board. Owners can act as their own electrical contractor on a single-family or duplex home they will occupy, with a permit and the required disclosure statement (s. 489.503(6)). See Florida electrician licensing.

Interior designers and remodelers

Designers can specify fixtures, layouts, color temperature and controls. The electrical contractor is responsible for code compliance: ratings, boxes, circuits, AFCI and GFCI protection, and the permit. Put both in the plan from the start to avoid surprises at inspection.

How much does it cost to install recessed lighting?

We found no dated, published cost study for recessed lighting installation in Texas or Florida, so we do not quote a per-light price. LBNL's 2023 presentation for ENERGY STAR gave a typical range of $250 to $750 for a new circuit, which applies only if your project needs one. What drives the total:

FactorLower costHigher cost
Type of workRetrofit kits in existing cansNew lights in a finished ceiling with no wiring
FixtureBasic canless wafer or kitAdjustable, high-color-quality or architectural fixtures
Ceiling accessOpen attic above a one-story homeSecond-floor ceilings, finished floors above, concrete condo slabs
Ceiling height and typeFlat 8 to 9 foot drywallVaulted, plaster or textured ceilings that need patching
Circuit capacityExisting lighting circuit can carry the loadNew circuit, AFCI breaker or panel space needed
ControlsSingle switchMultiple zones, dimmers, smart controls, new switch locations
Permits and finish workRepair-type workPermit, inspection, drywall repair and painting

Ask for a quote that lists the fixture model, IC and AT ratings, number of lights, switching and dimmers, any new circuit, the permit and who patches the ceiling. Compare more than one written quote. See comparing electrical quotes and electrician cost guide.

Ways to keep cost down without cutting safety

  • Group lights in rooms with easy attic access.
  • Use listed retrofit kits where existing cans are IC rated and in good shape.
  • Combine lighting with other electrical work on the same permit and visit.
  • Choose fixtures from one product line so dimmers match.

Upgrading lighting in an older Texas or Florida home

Older homes add a few extra checks before new lighting goes in:

  • Aluminum branch wiring (common in homes wired from about 1965 to the mid-1970s, per CPSC): connections to new fixtures and dimmers should be made by a qualified electrician using methods CPSC recognizes for aluminum wiring repairs, such as COPALUM crimps or AlumiConn connectors. IAEI notes device markings such as CO/ALR matter whenever aluminum conductors are involved. See aluminum wiring.
  • Cloth-insulated or knob-and-tube wiring can crumble when disturbed and is often not rated for insulation contact. See knob and tube wiring.
  • No neutral at switches limits smart dimmer choices.
  • No equipment ground at old boxes. Metal fixtures need a ground; see ungrounded wiring.
  • Old non-IC cans under added insulation. Replace them or restore clearance.
  • Panel capacity is rarely an issue for LED lighting, which draws little power, but a full or outdated panel may limit new circuits. See panel upgrades.

In Florida, insurers using the Citizens 4-point form ask about wiring type, including single-strand aluminum and cloth wiring, and flag hazards like exposed or unsafe wiring. A lighting remodel is a good time to fix those findings. See Florida 4-point inspection.

Room-by-room recessed and LED lighting guide

RoomWhat worksCode and rating notes
KitchenDownlights over the front edge of counters, pendants or downlights over the island, under-cabinet task lightsWall-switched lighting outlet required; AFCI on 15 and 20 amp, 120-volt circuits under the 2023 NEC; IC rating under insulation
Living and family roomsA few downlights for ambient light, adjustable or wall-wash trims toward walls and art, lamps on dimmable circuitsAFCI protection; dimmer compatibility
BedroomsCeiling fan with light, or a small number of dimmable downlights away from the bed's line of sightAFCI protection; fan-rated box if a fan is planned
BathroomsA damp or wet-rated light over the shower, vanity lighting at face height, an exhaust fan with light410.10(D) tub and shower zone; built-in receptacles need GFCI
Hallways and stairsDownlights spaced along the path, step lightsStairways need controls at each floor or landing level with an entry (210.70)
ClosetsSurface LED fixtures listed for closet storage space, or recessed with proper clearance410.16 closet rules
Garage and laundryBright, whiter light (3500 to 4100K or higher), surface LED fixturesLaundry areas need a controlled lighting outlet under the 2023 NEC
Covered porches and soffitsDamp or wet-rated downlightsDamp under a solid roof; wet where rain reaches

Rooms with tall or sloped ceilings need trims and housings designed for slopes, or adjustable trims, so the light points down instead of at the wall.

Trims and beam angles explained

The trim is the visible ring and the part that shapes the light. Common types:

  • Baffle trims have ridged black or white interiors that reduce glare.
  • Reflector trims have smooth, shiny interiors that push out more light, with more glare.
  • Adjustable (gimbal or eyeball) trims tilt to aim at art, fireplaces or walls.
  • Wall-wash trims push light across a wall for even brightness.
  • Lensed or shower trims seal the fixture for damp or wet locations.
  • Pinhole and small-aperture trims give a focused beam with a small visible opening.

Beam angle decides how wide the light spreads. Narrow beams light a small area brightly and suit accent lighting or high ceilings. Wide beams spread light for general room lighting. Mixing beam angles in a room is common: wide for ambient, narrow for accent.

A trim is part of the listed fixture. Use the trims the housing's label allows. IAEI's inspector notes that the wrong trim can change how heat escapes and trip the thermal protector.

What lighting controls does the code require?

NEC 210.70 sets where lighting outlets and controls are required in homes. IAEI's 2025 summary:

  • At least one lighting outlet controlled by a listed wall-mounted control in every habitable room, kitchen, bathroom, hallway, garage, accessory building and similar space.
  • Stairways need control at each floor level and landing level that includes an entryway.
  • Attics, underfloor spaces, basements and utility rooms used for storage or with equipment needing service need a lighting outlet near the equipment, controlled at the entry.
  • Exterior entrances at grade level need lighting.
  • The 2023 NEC added laundry areas and limited battery-only wall controls: a battery-powered wireless switch cannot be the only control unless the light turns on automatically if the battery fails.

That last rule matters for smart lighting. A battery remote stuck to the wall is a convenience, not a code-compliant switch, unless the system meets that exception. Plan a hardwired switch, a listed smart switch or a control that meets the rule.

Step by step: what a professional recessed lighting install looks like

  1. Walk-through and layout. The electrician confirms what each light is for, marks locations on the ceiling, and checks the panel and circuit.
  2. Check above the ceiling. From the attic or with a small inspection hole, confirm joists, ducts, pipes, insulation type and depth.
  3. Pull the permit if required.
  4. Turn off and verify power on the circuits involved.
  5. Cut openings with a hole saw sized to the fixture template.
  6. Run cable between fixture locations and to the switch, using the existing circuit or a new one, with AFCI protection where required.
  7. Install housings or canless fixtures with their junction boxes, following the listing and instructions.
  8. Seal for airtightness where the fixture and instructions call for it.
  9. Install switches and dimmers from the compatibility list, with neutrals where required.
  10. Test every light at full and low dim levels, and check for flicker or buzz.
  11. Inspection where permitted, then patch any drywall damage.
  12. Hand over the product labels, dimmer model and permit record.

Do LED upgrades save energy in Texas and Florida homes?

Yes, in two ways. First, the light itself uses far less electricity: ENERGY STAR says LED lighting produces light up to 90 percent more efficiently than incandescent bulbs, and certified downlights use 90 percent less energy than incandescent models. Second, incandescent bulbs throw off heat in every direction, as ENERGY STAR notes, so replacing them puts less waste heat into air-conditioned rooms, which matters in climates where cooling runs most of the year.

Airtight fixtures add savings by keeping conditioned air from leaking into the attic. If you are upgrading many old cans in a ceiling below an attic, replacing leaky housings with IC and AT rated fixtures or sealed retrofit kits gives you both benefits. See electrical energy efficiency and bills.

What to read on the box and spec sheet before you buy

Recessed and LED products look alike on the shelf. The labels tell you whether they are safe and legal for your ceiling:

  • Listing mark from a nationally recognized testing laboratory. The NEC requires installation per the listing (110.3(B)), and retrofit kits must be listed for the housing (410.6).
  • IC or non-IC. Required knowledge for any insulated ceiling.
  • AT (airtight). Recommended by ENERGY STAR under unconditioned attics.
  • Damp or wet location rating, and whether it depends on a particular trim.
  • Lumens and color temperature (K), plus whether the color is selectable or warms when dimmed.
  • Dimming: whether it is dimmable and which dimmers the maker has tested.
  • Compatible housings for retrofit kits, by brand and model.
  • Ceiling thickness and hole size for canless fixtures.
  • Warranty. ENERGY STAR certified downlights carry at least three years.
  • ENERGY STAR, which still applies to high-performing recessed downlights.

Keep the spec sheets. An inspector, a future buyer or an insurer may want to see them, and you will need the model numbers when a fixture fails.

Recessed lights in porch ceilings, soffits and condos

Porches, lanais and soffits

Recessed lights in porch ceilings and roof overhangs are in damp locations at a minimum, and wet locations where rain reaches them. IAEI's 2025 summary calls getting the location wrong the most common reason luminaires fail inspection in exterior spaces. Choose fixtures marked for the location, and in coastal Florida, finishes and trims made to resist corrosion. Insects and wasps like soffit fixtures, so sealed or lensed trims help. See outdoor lighting and yard wiring.

Condos and concrete ceilings

Many Florida condos and some Texas high-rises have concrete slab ceilings with no space above for a can. Options include surface-mounted LED disc or panel fixtures that mount to an existing ceiling box, or a dropped soffit built to hold recessed lights. Any cutting into a slab, and often any change to wiring in the ceiling, needs association approval and a permit. See condo and HOA electrical.

Beachfront homes and condos in Florida: sea turtle lighting rules

If your Florida home or condo faces a nesting beach, the recessed lights in your soffits, balconies and porch ceilings may be regulated by a local sea turtle lighting ordinance. State law directs the Department of Environmental Protection to designate the coastal areas sea turtles use for nesting and to adopt guidelines for local rules that control beachfront lighting to protect hatchlings (s. 161.163). Coastal counties and cities write the actual ordinances, so ask your building department or condo association what applies before you buy fixtures.

The Florida Fish and Wildlife Conservation Commission (FWC) sums up wildlife-friendly lighting as keep it low, keep it long, keep it shielded:

  • Low: mount fixtures as low as possible and use the lowest output that does the job.
  • Long: use long-wavelength light, greater than 560 nanometers, such as amber, orange or red LEDs. A standard 3000K white LED does not meet this.
  • Shielded: use fixtures that meet or exceed full cutoff, so the lamp or glowing lens is not directly visible from the beach. A deep-regressed trim helps in a soffit.

FWC and the U.S. Fish and Wildlife Service run a Wildlife Lighting Certification Program that lists certified fixtures and bulbs. Turning off lights you do not need is still the simplest fix.

Smart bulbs vs. smart switches in recessed lights

You can make recessed lighting smart in two ways. Smart bulbs or smart retrofit modules put the radio in each light. They need constant power, so the wall switch must stay on, and if someone flips it off the lights drop off the network. They suit renters and single fixtures. A smart switch or dimmer controls the whole group of ordinary LED downlights from the wall. It keeps the wall switch working for guests and is usually simpler for a room full of cans, but many models need a neutral in the switch box. Do not combine a smart bulb with a dimmer; most smart bulbs are meant to run on a plain on-off switch. Whichever you pick, the battery-only control rule in 210.70 still applies to required lighting. See smart home electrical.

Lighting terms in plain English

  • Luminaire: the code word for a complete light fixture.
  • Housing or can: the metal body of a recessed light inside the ceiling.
  • Trim: the visible ring and reflector or baffle that shapes the light.
  • Retrofit kit: a listed LED module and trim designed to install in an existing housing.
  • Canless or wafer fixture: a thin LED fixture with a separate junction or driver box, no can.
  • Driver: the electronic power supply that runs an LED.
  • Lumens: how much light a source gives off.
  • Kelvin (K): the color appearance of white light, warm to cool.
  • IC: rated for insulation contact.
  • AT: airtight, limiting air leakage through the fixture.
  • Damp and wet location: code categories for moisture exposure that decide which fixture rating you need.
  • Thermal protector: a built-in device that shuts a recessed light off if it overheats.
  • Neutral: the white conductor that completes the circuit; many smart switches need one in the box.

Common recessed lighting mistakes

  1. Installing non-IC cans in insulated ceilings, or adding insulation over existing non-IC cans.
  2. Using housings that are not airtight under a hot, unconditioned attic.
  3. Mixing light brands on one dimmer, or ignoring the compatibility list.
  4. Putting a light that is not damp or wet rated in a shower.
  5. Using unlisted LED conversions, or a kit not made for that housing.
  6. Cutting holes without checking for joists, ducts, pipes or wires above.
  7. Burying canless junction boxes where they cannot be reached through the opening.
  8. Over-lighting the center of a room and leaving walls dark.
  9. Choosing different color temperatures in the same room.
  10. Back-stabbing wires into devices beyond what the device is listed for.
  11. Skipping the permit, then facing problems at resale or after an insurance inspection.

How to choose a provider

  • Decide on the purpose of each light: ambient, task or accent.
  • Check above the ceiling for joists, ducts, pipes and insulation before finalizing the layout.
  • Buy Type IC fixtures for any insulated ceiling and Type AT under an unconditioned attic.
  • If keeping existing cans, confirm they are IC rated and use a listed retrofit kit made for that housing.
  • Match color temperature within each room; compare lumens, not watts.
  • Choose dimmers from the light maker's compatibility list and stay within the LED load rating.
  • Use damp-rated trims in showers and wet-rated where spray reaches the fixture.
  • Keep fixtures out of closet storage spaces unless listed for them.
  • Ask whether your project needs a new circuit, AFCI protection or a permit.
  • Hire a licensed electrician for new wiring, and verify the license with TDLR or DBPR.
  • Keep the product labels, manuals and permit record for future buyers and insurers.
  • If lights cycle off and on, turn them off and have the housing and lamp ratings checked.

Related electricians guides

Electricians by state and city

Questions people ask

What is an IC-rated can light?

IC means insulation contact. An IC-rated recessed housing is designed to be in direct contact with thermal insulation without overheating. Non-IC housings must keep at least 3 inches of clearance to insulation and 1/2 inch from combustibles, according to IAEI's explanation of the NEC and ENERGY STAR's guidance. In Texas and Florida attics full of blown-in insulation, IC-rated fixtures are the practical choice.

Are wafer lights better than cans?

They are different. Canless wafer lights install quickly through a small hole, fit shallow ceilings, and many are rated for insulation contact and airtight. But the LED and driver are one unit, so when it fails you replace the fixture. Cans with replaceable modules let you change the light later. Either way, use listed products installed per their instructions.

Can I put LED bulbs in my old recessed cans?

Yes, if the bulbs are rated for enclosed or recessed fixtures and the can is in good condition. LEDs run cooler than incandescent bulbs, but ENERGY STAR notes heat still shortens LED life, so a sealed can in a hot attic is hard on bulbs. For a cleaner and longer-lasting result, use a listed retrofit kit designed for that housing.

Why do my recessed lights turn off by themselves?

The thermal protector is probably tripping. IAEI explains recessed luminaires must have a device that disconnects the lamp if the housing overheats. Common causes are a bulb larger than the housing is rated for, the wrong trim, insulation too close to a non-IC housing, or a misadjusted socket. Turn the light off and have an electrician check it.

Do I need an electrician to install under-cabinet lights?

Not for plug-in fixtures or low-voltage systems with a plug-in driver. Hardwiring a fixture or a driver to a line-voltage circuit is electrical work. In Texas, that requires a TDLR-licensed electrician unless you are the owner-occupant and your city allows it. In Florida, it requires a licensed electrical contractor or an owner-builder permit for your own home.

What color temperature should I choose?

ENERGY STAR describes 2200 to 3000K as warm, similar to incandescent; 3500 to 4100K as whiter; and 5000 to 6500K as bluish white. Many homes use warm light in living spaces and bedrooms and slightly whiter light in kitchens and baths. Keep the same color within a room, and consider fixtures that warm as they dim for evenings.

How long do LED recessed lights last?

ENERGY STAR explains that LEDs usually dim gradually rather than burning out, and their rated life is the point at which light output is predicted to fall by 30 percent. Heat shortens that life, which is why IC-rated, well-ventilated or airtight designs and products tested for thermal performance matter in hot Texas and Florida attics. ENERGY STAR certified downlights carry at least a three-year warranty.

Is a battery-powered wireless switch allowed for recessed lights?

Not as the only control in most cases. Under the 2023 NEC, a battery-only wall control cannot be the sole means of controlling a required lighting outlet unless the lighting turns on automatically when the battery fails, according to IAEI. A wireless remote can add convenience alongside a compliant wired switch or listed smart control. Ask your electrician which options meet your adopted code.

How many recessed lights can go on one circuit?

It depends on the circuit rating and each fixture's wattage, and LEDs draw so little that the limit is rarely reached in homes. A more common limit is the dimmer's rated LED load and the maker's compatibility list. The NEC also treats lighting expected to run three hours or more as continuous for sizing feeders and services. Let your electrician check the circuit, the dimmer rating and AFCI requirements.

Should I replace old halogen or incandescent cans or just change the bulbs?

If the old cans are IC rated, in good condition and not overheating, a listed LED retrofit kit for that housing is usually enough. Replace the housing if it is non-IC and touching insulation, rusted, cycling off from heat, or leaking air into a hot attic. ENERGY STAR recommends IC models where insulation touches the fixture and airtight models under unconditioned attics, which most old cans are not.

Do LED lights work with old wiring?

LEDs draw little current, so they rarely overload old circuits. The concerns are the connections and the boxes: brittle cloth insulation, aluminum branch wiring, missing grounds and no neutral at switches. An electrician should check those before adding fixtures or dimmers. CPSC recognizes specific repair methods for aluminum wiring connections, such as COPALUM crimps and AlumiConn connectors.

Can recessed lights go in a bathroom ceiling over a tub?

Yes. Fixtures within the tub or shower outline up to 8 feet above the rim must be marked for damp locations, or wet locations where they are subject to spray, under NEC 410.10(D). Hanging, chain, track and cord-connected fixtures and fans with light kits are not allowed within 3 feet horizontally and 8 feet vertically of the tub rim.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration