Why Is the Power Out in Half My House (and What Do I Do)?

When some rooms go dark and others stay on, the cause can be a simple tripped breaker or a dangerous lost neutral or damaged service line. Here is how to tell the difference safely, and who to call in Texas and Florida.

Power out in half a house usually means one of the two 120-volt legs feeding your home is lost, or a breaker has tripped. Reset any tripped breakers first. If lights are dim in some rooms and too bright in others, or 240-volt appliances like the AC and dryer stop, treat it as urgent: turn off sensitive electronics and call your utility's outage line, then a licensed electrician. Never open the panel or touch the meter.

Key facts

  • Texas licensing law applies to all premises wiring that begins where the utility's facilities end; equipment under the utility's exclusive control is outside it (Tex. Occ. Code 1305.003).
  • Oncor says the customer typically owns the meter base and the wiring in it, plus the conduit and wiring to the weatherhead; Oncor owns the pole, transformer and service line.
  • FPL says homeowners own the weatherhead, attachment hardware, riser, meter box, ground wire and rod; FPL owns the service line and meter.
  • CPS Energy says its responsibility ends at the weatherhead or meter can, and that a partial-house outage may be in the breaker box.
  • Texas utilities must keep distribution voltage within ANSI C84.1 limits (16 TAC 25.51); Florida utilities must keep delivery voltage within 5% of their standard voltage (Fla. Admin. Code 25-6.046).
  • Oncor's outage line is 888-313-4747; FPL's is 1-800-4-OUTAGE; CPS Energy takes power quality reports at 210-353-2222.
  • After storm damage, Oncor, FPL, TECO and JEA all require customer-owned equipment such as the meter base or weatherhead to be repaired by a licensed electrician before they reconnect.

First, the quick answer: is this a breaker or something bigger?

Most homes in Texas and Florida get 120/240-volt single-phase power. That sounds technical, but the idea is simple. Two hot wires, called legs, come from the utility transformer. Each leg carries about 120 volts compared with a third wire, the neutral. Across both legs you get about 240 volts, which runs big loads like the air conditioner, electric dryer, range and water heater.

Inside your panel, breakers alternate between the two legs. So when one leg is lost, roughly half the circuits in the house go dead, and the 240-volt appliances stop because they need both legs. That is why the problem often looks like "half the house" rather than one room.

What you seeMost likely causeUrgency
One room or a few outlets dead, everything else normalTripped breaker or tripped GFCI outletLow. Check the panel and GFCIs.
About half the house dead, AC and dryer will not run, other lights normalLost leg (utility side, meter base, main breaker or service wire)High. Call the utility outage line.
Some lights very dim, others very bright, bulbs burning out, electronics acting oddLost or loose neutralEmergency for your equipment. Turn off electronics and call now.
Neighbors have the same problemUtility transformer or lineReport to the utility.
After a storm, the wire to your house is sagging or the meter box is pulled offDamaged service drop, weatherhead or meter baseEmergency. Stay away and call the utility.

Step 1: Safe checks any homeowner or renter can do

These checks do not require opening anything. Do them with dry hands, standing on a dry floor. If the panel is wet, hot, buzzing, smells burnt or shows scorch marks, skip all of this and go to the emergency section below.

  1. Look outside and ask a neighbor. If the street is dark or the neighbor has the same odd symptoms, the problem is likely on the utility side. Report it.
  2. Open the panel door (not the cover). The door is the small hinged flap. The inner cover with screws stays on. Look for any breaker handle that is in the middle position or pointing the other way from its neighbors.
  3. Reset a tripped breaker correctly. Push the handle firmly to OFF first, then back to ON. Many breakers will not reset if you only push them toward ON.
  4. Check the double-pole breakers. A 240-volt circuit uses a double-wide breaker with a tied handle. If one half of a double-pole breaker has failed internally, the handle can look normal while one leg is dead. You cannot see this from outside. An electrician has to test it.
  5. Find and reset GFCI outlets. One GFCI outlet in a bathroom, garage, kitchen, laundry or outdoors can protect other outlets downstream. Press RESET firmly on each one you find. See our guide to outlets that stop working for where GFCIs hide.
  6. Note what works and what does not. Write down which rooms, which appliances and whether lights look normal, dim or extra bright. This list saves the electrician time and you money.

If a breaker trips again right after you reset it, leave it off. A breaker that will not hold is telling you something is wrong on that circuit. Our guide on breakers that keep tripping explains the causes.

What should I never do?

  • Never remove the panel's inner cover. The large wires coming in from the meter stay live even with the main breaker off. Only a qualified electrician should work there.
  • Never pull, cut or tamper with the meter or its seal. The meter belongs to the utility in Texas and Florida. The meter socket behind it can stay energized.
  • Never touch a sagging or fallen service wire, a tree resting on wires, or anything those wires touch, such as a fence or gutter. OSHA warns that downed wires can energize fences, water pipes, bushes, trees and buildings, and that lines can stay energized even when they are not sparking.
  • Never backfeed a generator by plugging it into a wall outlet. The CPSC says this creates an electrocution risk for utility workers and neighbors on the same transformer.
  • Never use a multimeter in the panel unless you are trained. Testing in a live panel is how people get burned by an arc flash.

What is a lost neutral, and why is it dangerous?

The neutral is the return path for 120-volt circuits. It also keeps both legs balanced at about 120 volts each. When the neutral connection breaks or gets loose, at the transformer, the service drop, the meter base or the panel, the two legs are no longer held steady. The voltage on each side starts to float depending on what is turned on.

Here is a real-world example. You turn on a hair dryer in the bathroom and the kitchen lights suddenly get much brighter while the bedroom lights get dim. One side might be sitting at 80 volts while the other side jumps to 160 volts. That high side can destroy TVs, computers, appliance control boards and LED bulbs in minutes, and it can overheat equipment.

Signs of a lost or loose neutral

  • Lights get brighter on one side of the house when something big turns on elsewhere.
  • Bulbs burn out fast or several electronics fail around the same time.
  • Fans speed up or slow down for no reason.
  • Lights dim and brighten in a pattern that follows appliance use.
  • A tingle from a faucet or a metal fixture, which can mean current is finding another path. See our page on shocks and tingles.

What to do

  1. Turn off and unplug expensive electronics.
  2. If you can do it without opening the panel cover, switch the main breaker OFF to protect your equipment.
  3. Call your utility's outage or emergency line first. Many neutral failures are on the utility side (transformer connection or service drop), and the utility will check its side at no charge for its equipment.
  4. If the utility finds its side is fine, call a licensed electrician to check the meter base, main lugs and panel neutral bar.

Is it my problem or the utility's? Ownership by Texas and Florida utility

Who fixes it depends on where the failure is. In general, the utility owns the wires from the pole to your house and the meter. You own most of what is attached to your house. But the exact line varies, so check your utility. Here is what each utility says on its own website or materials.

UtilityUtility ownsCustomer owns
Oncor (Dallas-Fort Worth and much of North and West Texas)Pole, transformer, service line to the weatherhead, the meterMeter base and wiring in it, conduit and wiring connecting the weatherhead
CenterPoint (Houston)Lines and meterMeter box and weatherhead, per a 2024 CenterPoint chart reported by KPRC; confirm on CenterPoint's site
Austin EnergyThe meter and the cable inside the conduit from the transformer to the meter base (underground)Meter base, point of attachment for the service drop, service entrance cable, customer conduit
CPS Energy (San Antonio)Delivery up to the building, at the weatherhead or meter can, and the meterEquipment past that point
FPLService line and electric meterWeatherhead, attachment hardware, service stack, riser, meter box, ground wire and rod
Tampa Electric (TECO)Meter and service line (storm damage)Weatherhead, riser and meter box
JEA (Jacksonville)Service line up to the attachment point and the meterWeatherhead, riser and meter can
Duke Energy Florida (Orlando area and others)Its lines and meterDuke tells customers with damage to the meter base, panel or customer wiring to contact their local municipality; inspections may be required

We could not load an AEP Texas page stating its meter-base policy. If you are an AEP Texas, TNMP, Entergy Texas or co-op customer, ask your utility directly. For a deeper look, see who owns the meter base and service drop.

The Texas twist: call your wires company, not your retail provider

In deregulated areas of Texas such as Houston and Dallas-Fort Worth, you buy power from a retail electric provider, but a separate company delivers it. Oncor's own FAQ explains that it delivers electricity but does not sell it. Outages, voltage problems and damaged lines go to the delivery company, called the TDU (for example Oncor or CenterPoint). Austin and San Antonio are different: Austin Energy and CPS Energy are city-owned utilities that both sell and deliver power.

Should I call the utility or an electrician first?

For a partial outage, call the utility first in almost every case. It costs you nothing to report, and the utility can tell you quickly whether its transformer, line or meter is the problem. Oncor's FAQ, for example, tells customers to check the breaker first and then report the outage if power is still not restored.

  • Call 911 if there is fire, smoke, sparking at the meter, a wire on the ground, or someone has been shocked.
  • Call the utility for half-house outages, dim/bright lights, a sagging service drop, or a damaged meter.
  • Call a licensed electrician when the utility says its side is fine, when a breaker will not reset, when a double-pole breaker seems to have failed, or when customer-owned parts (meter base, weatherhead, riser, panel) are damaged.
UtilityOutage or emergency line
Oncor888-313-4747 (24/7); 911 for a downed line
Austin Energy512-322-9100 for downed lines or trees on lines; 911 for immediate danger
CPS Energy210-353-HELP (4357) for electric emergencies and downed lines; 210-353-2222 for residential service questions, including power quality
FPL1-800-4-OUTAGE
CenterPoint, AEP Texas, TECO, JEA, DukeUse the number printed on your bill or the utility's website. We did not verify these numbers for this guide.

Our page on reporting outages to Texas and Florida utilities has more detail, and the electrical emergency decision guide covers when to call 911.

Why did my AC and dryer stop but the lights still work?

Central air conditioners, heat pumps, electric dryers, ranges and electric water heaters run on 240 volts, so they need both legs. If one leg is gone, these appliances either stop or hum without starting, while about half of your 120-volt lights and outlets keep working.

This is the classic sign of a lost leg. Possible causes, from most to least common:

  1. A utility fuse or connection problem on the transformer or service drop.
  2. A loose or burned connection in the meter base.
  3. A failed main breaker, where one pole has gone bad internally.
  4. A damaged service entrance cable between the meter and the panel.

Do not keep resetting the AC. A compressor trying to start on low or uneven voltage can overheat. Turn the thermostat off until the problem is fixed. For AC-specific electrical issues, see HVAC electrical problems.

What does 120 volts on one leg and 0 on the other mean?

If an electrician or a trained person reads about 120 volts from one leg to neutral and 0 from the other leg to neutral at the main lugs, the second leg is not arriving at your panel. The next test is at the meter base, done by the utility or an electrician. If the leg is missing at the line side of the meter base, the problem is on the utility side. If it is present at the meter but missing at the panel, the problem is in the customer-owned service entrance wiring or main breaker.

Readings that are uneven, such as 95 volts on one leg and 145 on the other, point to a neutral problem. Normal readings should be close to the utility's nominal voltage. Texas rules require utilities to keep distribution voltage within the limits of ANSI C84.1 (16 TAC 25.51). Florida rules say voltage at the point of delivery should not be more than 5% above or below the utility's standard voltage (Fla. Admin. Code 25-6.046). For a 120-volt nominal service, 5% works out to about 114 to 126 volts.

We repeat the warning: this testing is for trained people with proper meters and protective gear. A homeowner with a cheap meter inside a live panel can be badly hurt.

Why did half the house lose power after a storm?

Wind, falling limbs and flying debris often damage the service drop (the overhead wire from the pole), the weatherhead (the hooded cap on the pipe at your roofline), the riser pipe, or the meter box. Any of these can break one leg or the neutral while leaving the rest connected.

After the May 2024 Houston derecho and Hurricane Beryl in July 2024, which the Public Utility Commission of Texas says disrupted service for 2.7 million customers including 2.2 million CenterPoint customers, many homes could not be reconnected until customer-owned equipment was repaired. In Florida, FPL, TECO and JEA all tell customers the same thing: if the weatherhead, riser or meter box is damaged, a licensed electrician must repair it, and it must pass any required inspection, before the utility connects power.

Typical post-storm steps

  1. Stay away from any damaged wire and report it to the utility. Oncor customers can request a temporary hazardous disconnect at 888-313-6862.
  2. Photograph the damage from a safe distance for your insurer.
  3. Hire a licensed electrician to repair customer-owned parts.
  4. Get the city or county inspection if required. Oncor notes that most city codes require an inspection before service is restored after a meter base is damaged.
  5. Call the utility to reconnect. Oncor notes a nominal charge for reconnecting after a storm hazardous disconnect.

More on storms in our hurricane electrical safety guide.

Could ERCOT rotating outages cause a partial outage?

Usually no. ERCOT-directed rotating outages, also called load shed, cut whole neighborhoods or feeders at the utility level, so your entire house goes dark, not half of it. Oncor explains that controlled outages are spread across its territory on a rotating basis when ERCOT tells utilities to reduce demand. During Winter Storm Uri in February 2021, ERCOT's peak load shed reached 20,000 megawatts.

What can happen after a big event is equipment damage when power returns. Oncor noted during Uri that some transformers were damaged when they had to power back up large amounts of load at once. A damaged transformer can leave one leg or the neutral weak, so a partial outage or odd voltage after restoration is worth reporting. See our ERCOT grid outages guide.

Can a bad meter base cause half the house to lose power?

Yes. The meter base, also called the meter socket or meter can, holds the jaws the meter plugs into. Over time, heat, loose connections, corrosion and storm damage can burn one jaw or one connection. When that happens, one leg can drop out or flicker. Signs include a burnt smell or discoloration near the meter, a buzzing sound, a meter that looks loose or tilted, or rust on the box.

In Florida's salty coastal air, corrosion of outdoor equipment is a real concern. NEMA's 2026 guide on water-damaged electrical equipment notes that salt water residue is corrosive and conductive. In Texas, Oncor, Austin Energy and CPS Energy all treat the meter base as customer-owned. That means the repair is usually on your bill, done by a licensed electrician, often with a city permit and inspection.

How much does it cost to fix?

We did not find a dated study that prices partial-outage repairs specifically, so we will not quote one. What we can say from published sources:

  • Utility-side repairs (transformer, service drop, the meter) are normally handled by the utility.
  • A reset breaker or GFCI costs nothing.
  • A failed breaker, meter base or service entrance repair is a customer cost. For a sense of scale on bigger jobs, a Lawrence Berkeley National Laboratory (LBNL) survey published in August 2026 found a median cost of $3,500 for a single-family main service panel replacement (middle half of answers: $2,100 to $5,000). That is a full panel job, not a typical repair.
  • Permit fees are usually small. The same LBNL survey found typical residential electrical permit fees clustered near a $100 median, with wide variation by city.

Ask for a written quote that lists the parts, the permit and the inspection. Our electrician cost guide and hiring checklist can help.

Who can do the repair in Texas and Florida?

Texas: Electrical work must be done by a person licensed by the Texas Department of Licensing and Regulation (TDLR), working through a licensed electrical contractor, unless an exemption applies. Owner-occupants have a limited exemption for their own home, but only for work not specifically regulated by a city ordinance (Tex. Occ. Code 1305.003(a)(6)). Cities such as Houston require permits and inspections for things like meter and service work. Check a license at TDLR's online search or call 800-803-9202.

Florida: Electrical contracting requires a state certification or local registration under Chapter 489, Part II. An owner-builder exemption lets owners do electrical work on their own single-family home or duplex for their own use, with a permit (s. 489.503(6)). Florida's $7,500 small-job permit exemption does not cover electrical work on single-family homes (s. 553.79), so ask your building department whether your repair needs a permit. Utilities such as FPL warn against hiring unlicensed electricians for service repairs. Verify licenses through DBPR.

See Texas licensing and Florida licensing for details.

Renters: what to do

If you rent, report the outage to the utility first if it affects half the unit or more, and then notify your landlord in writing. In Texas, a landlord must make a diligent effort to repair conditions that materially affect health or safety after proper notice (Tex. Prop. Code 92.052), and seven days is presumed a reasonable repair time (92.056(d)). In Florida, landlords must comply with applicable building, housing and health codes (s. 83.51(1)(a)). A lost neutral or dead circuits feeding a refrigerator or AC in summer is a serious condition. Do not attempt panel or meter work yourself. Our landlord and tenant electrical guide covers notices and remedies.

How to choose a provider

  • Look outside: are neighbors out too? If yes, report to the utility.
  • Open only the panel door and look for tripped or middle-position breakers.
  • Reset breakers by pushing fully OFF, then ON. Leave off any that trip again.
  • Press RESET on every GFCI outlet in bathrooms, kitchen, garage, laundry and outside.
  • If lights are dim in some rooms and bright in others, unplug electronics and turn off the main if you can do so without removing covers.
  • Call the utility outage line (TDU in deregulated Texas) before an electrician.
  • Stay well away from sagging or fallen wires and call 911 if wires are down or sparking.
  • Photograph storm damage to the weatherhead, riser and meter box from a safe distance.
  • Hire a licensed electrician for customer-owned repairs and ask about permit and inspection.
  • Call the utility to reconnect once repairs pass inspection.

Related electricians guides

Electricians by state and city

Questions people ask

Why is power out in half my house but not the other half?

Your home gets two 120-volt legs. Breakers alternate between them, so losing one leg kills about half of your circuits and every 240-volt appliance. The leg can be lost at the utility transformer, the service drop, the meter base, the main breaker or the service wire into the panel. A single tripped breaker or GFCI usually affects only one area. If big appliances like the AC stopped too, report it to the utility first.

Is a partial outage my problem or the utility's?

It depends on where the failure is. Utilities generally own the service line and the meter. Oncor, Austin Energy, FPL, TECO and JEA all say customers own the meter base or meter box, and most also put the weatherhead and riser on the customer. Call the utility first. If its equipment is fine, the issue is in your meter base, main breaker or wiring, and a licensed electrician must fix it.

Can a lost neutral cause half the house to lose power?

A lost neutral more often causes lights to go dim on one side and bright on the other, rather than a clean outage. Some circuits may appear dead while others see high voltage that can ruin electronics. Treat it as urgent: unplug electronics, turn off the main if you can without opening the panel cover, and call the utility. If the utility's side tests fine, call a licensed electrician right away.

Is it dangerous if lights get brighter when an appliance turns on?

Yes. Lights getting brighter, not just briefly dimmer, when a large load starts is a classic sign of a loose or broken neutral. Voltage on one side can rise well above normal and damage equipment or cause overheating. Do not wait for it to get worse. Unplug electronics and call your utility's outage line, then an electrician if the utility finds no problem on its side.

How do I reset a breaker that looks fine but isn't?

Push the handle firmly all the way to OFF, then back to ON. Some tripped breakers rest only slightly off center. If a double-pole breaker has failed inside, one leg can be dead while the handle looks normal. You cannot detect that by looking, and testing requires work inside the panel. Call a licensed electrician rather than removing the panel cover yourself.

Should I call the utility or an electrician first for a partial outage?

Call the utility first, unless there is fire, smoke, sparking or a wire down, in which case call 911. The utility can check its transformer, service line and meter for free. In deregulated Texas, call the wires company such as Oncor or CenterPoint, not your retail provider. If the utility clears its side, hire a licensed electrician for the meter base, main breaker or panel.

Who fixes a damaged service drop or weatherhead?

The utility fixes the service drop wire it owns. The weatherhead, riser pipe and meter box are typically the homeowner's responsibility at Oncor, FPL, TECO and JEA, and Austin Energy puts the point of attachment and service entrance cable on the customer. A licensed electrician repairs those, any required inspection follows, and then the utility reconnects. Oncor charges a nominal reconnect fee after a storm hazardous disconnect.

Why do some outlets work and others don't with no tripped breaker?

The most common reason is a tripped GFCI outlet somewhere else that feeds the dead outlets. Check bathrooms, kitchen, garage, laundry, outdoor outlets and any GFCI breakers in the panel. Other causes include a loose connection at an outlet upstream, a failed backstabbed connection, or a switched outlet controlled by a wall switch. If several rooms are out and no GFCI resets, call an electrician.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration