Local Guide · Foundation repair contractors
What Do Foundation Repair Terms Mean? A Plain-English Glossary of 116 Terms for Texas and Florida
Plain-English definitions of the engineering, construction, insurance and legal terms in foundation reports, repair bids and claims, including Texas and Florida statutory terms like RCLA, catastrophic ground cover collapse and neutral evaluation.
Underpinning means adding piers or piles under an existing foundation to carry it to firmer soil. Refusal is the point where a pier will not go deeper under the set force. The active zone is the soil layer whose moisture changes with the seasons. A grade beam is a thick reinforced band in a slab. Heave is upward movement. In Florida law, sinkhole loss and catastrophic ground cover collapse have narrow statutory definitions in Fla. Stat. 627.706.
Key facts
- Florida's catastrophic ground cover collapse requires abrupt collapse, a visible depression, structural damage and a government order to vacate (627.706(2)(a)).
- Florida defines sinkhole activity as settlement or weakening of supporting earth caused by soil moving or raveling into voids created by water acting on limestone or similar rock (627.706(2)(i)).
- Texas defines a construction defect to include deficiencies in the repair of an existing residence (Property Code 27.001(3)).
- Florida's neutral evaluation for sinkhole disputes is nonbinding but mandatory if either party requests it (627.7074).
- The ASCE Texas guidelines use an L/360 deflection limit and say a tilt over 1 percent is usually noticeable.
- The Florida Building Code treats soil as expansive when it has a plasticity index of 15 or more and meets other criteria, or an expansion index over 20 (FBC 1803.5.3).
- A Florida notice of commencement is void if work does not begin within 90 days of recording (713.13).
- FEMA defines substantial damage as damage costing 50 percent or more of pre-damage market value to restore (44 CFR 59.1).
How to use this glossary
Foundation reports, repair proposals, insurance letters and contracts use a lot of jargon. This glossary explains the words homeowners, buyers and sellers in Texas and Florida run into most, in plain English. Legal terms include the statute that defines them, so you can check the source. Where a term has its own guide, the definition links to it.
Two cautions. First, many legal terms mean something narrower than everyday English. A Florida "sinkhole loss" is not any hole near your house, and a "catastrophic ground cover collapse" requires a government order to vacate. Second, engineering terms like refusal, deflection and tilt are measured differently by different engineers. Ask yours how they define the numbers in your report.
Foundation terms: A to B
Active zone: The layer of soil near the surface whose moisture changes with the seasons and drives most shrink and swell. Below it, moisture stays fairly steady. Deep piers are meant to reach below the active zone so the house rides on soil that does not move much.
Actual cash value (ACV): An insurance payment based on replacement cost minus depreciation. In a Florida sinkhole claim, the insurer may limit payment to actual cash value, which excludes underpinning and grouting, until you sign a repair contract (Fla. Stat. 627.707(5)(a)).
Anchor (helical): The steel shaft with screw-like plates that is turned into the ground in a helical pier system. See helical piers.
Backfill: Soil put back into a hole or trench after piers are installed or plumbing is repaired. Poorly compacted backfill can settle and hold water against a foundation.
Base (concrete block and base): A precast or poured concrete pad that a pier-and-beam support sits on. Houston allows some block-and-base repairs within city engineered limits using City Engineer Details.
Beam (grade beam): A thicker, reinforced band of concrete, usually around the perimeter and in lines under a slab, that stiffens the foundation and carries loads to the soil or piers.
Bell-bottom pier: A drilled concrete pier with a wider, bell-shaped base at the bottom to spread the load. See drilled bell-bottom piers.
Bracket: The steel piece that connects a push pier or helical pier to the foundation's footing or beam so the pier can carry the house.
Brick ledge: The step at the outer edge of a slab where the brick veneer sits. Cracks in the brick often start near the ledge when the slab edge moves.
Foundation terms: C
Cable (tendon): See Post-tension tendon.
Cantilever: A part of a structure that sticks out past its support, such as a slab edge beyond the last pier.
Catastrophic ground cover collapse (CGCC): A Florida insurance term. It requires all four of: an abrupt collapse of the ground cover, a depression clearly visible to the naked eye, structural damage to the building including the foundation, and the structure being condemned and ordered vacated by the government. Mere settling or cracking does not qualify (Fla. Stat. 627.706(2)(a)). Every Florida property insurer must cover it.
Chapter 558: Florida's pre-suit notice law for construction defects. A claimant must serve a written notice of claim at least 60 days before suing (Fla. Stat. 558.004). See Florida chapter 558.
Claim of lien: A recorded document by an unpaid contractor or supplier claiming a lien on the property. In Florida, it must be recorded within 90 days after final furnishing (713.08(5)).
Compaction: Pressing soil to make it denser and stronger. Fill under slabs must be compacted. FGS lists improperly compacted soil as one cause of sinkhole-like depressions.
Compaction grouting: Pumping a thick, low-slump grout into the ground under pressure to densify loose soil and fill voids. It is a common Florida sinkhole repair method, often paired with chemical grouting near the surface.
Construction defect: Texas defines it as a deficiency in the design, construction or repair of a new residence, an alteration or repair of an existing residence, or an appurtenance (Property Code 27.001(3)). Florida's definition covers deficiencies in design, construction, repair, alteration or remodeling of real property (558.002(5)).
Contributing zone: Land in the Edwards Aquifer area where rain runs off toward the recharge zone. TCEQ requires plan review before certain construction there.
Crawl space: The open space under a pier-and-beam house. A Texas inspector need not enter a crawl space with under 18 inches of headroom or an opening smaller than 24 by 18 inches (22 TAC 535.228(a)(2)).
Cribbing: Stacked blocks or timbers used to temporarily support a structure while it is lifted or repaired.
Cut and fill: Leveling a sloped lot by cutting soil or rock from the high side and placing it on the low side. Fill can settle more than cut ground.
Foundation terms: D to E
Deflection: How much a beam or foundation bends between supports. The ASCE Texas guidelines use an L/360 deflection limit, borrowed from the IRC for floor framing, when evaluating foundation profiles.
Differential settlement: When parts of a foundation move by different amounts. It causes more cracking than a whole house settling evenly.
Disclosure notice (Texas): The seller's written notice required by Texas Property Code 5.008, with questions on foundation and slab defects, previous structural repair, drainage, and soil movement.
Downspout extension: A pipe or splash block that carries roof water away from the foundation. ASCE Texas recommends extending downspouts past planting beds.
DTPA: The Texas Deceptive Trade Practices-Consumer Protection Act. A consumer must give written notice at least 60 days before suing for economic damages (Bus. and Com. Code 17.505).
Elevation survey: A set of relative floor elevation readings across a house, usually drawn on a floor plan. It shows tilt and high and low spots. See foundation elevation surveys.
Engineer of record: The licensed engineer who seals the repair plan and has authority over changes, as described in the ASCE Texas guidelines.
Epoxy injection: Filling a crack with epoxy resin to bond it. ASCE Texas says injecting slab cracks about 1/32 inch and wider is meant to restore stiffness across the crack.
Expansion index (EI): A lab test number for how much a soil swells. Under the Florida Building Code, soil with an expansion index over 20 is considered expansive (FBC 1803.5.3).
Expansive soil: Clay soil that swells when wet and shrinks when dry. See expansive clay soil in Texas.
Foundation terms: F to G
Fault line: A break in rock where the ground has moved. Texas sellers must answer whether they know of fault lines on the property (Property Code 5.008).
Fill: Soil brought in to raise or level a building site. Settlement of fill is a common cause of foundation problems in Florida and on Hill Country lots.
Floating slab: A slab that rests on the ground without deep supports. Most Texas and Florida slab homes are built this way.
Floodplain (Special Flood Hazard Area): Land FEMA maps as having a 1 percent annual chance of flooding. Repairs in these zones can trigger extra permit rules, such as Houston's floodplain review for foundation repair.
Footing: The wider base of a wall or column that spreads the load into the soil.
Frieze board: The trim board at the top of an exterior wall under the eaves. Separations there are an adverse-performance sign Texas inspectors report (22 TAC 535.228).
Gap (soil gap): Space between the soil and the slab edge, caused by shrinking clay in dry weather.
Geotechnical engineer: An engineer who studies soil and rock. A geotechnical report may include soil borings and lab tests.
Gilgai: Small natural mounds and dips on the surface of strongly shrink-swell clay soils.
Grade: The level and slope of the ground. ASCE Texas recommends ground sloping at least 6 inches over the first 10 feet away from the foundation where practicable.
Grade beam: See Beam.
Ground-penetrating radar (GPR): A tool that sends radar pulses into the ground to find voids and layers. FGS lists GPR among tools consultants use to locate sinkhole cavities.
Grout: A fluid cement or chemical mix pumped into soil or voids. See Compaction grouting.
Foundation terms: H to L
Heave: Upward movement of a foundation, usually from swelling clay or a water leak under the slab.
Helical pier: A steel shaft with helix plates screwed into the ground to support a foundation. Installation torque is used to estimate capacity.
Heritage tree: In Austin, a large tree of listed species that the city regulates. Austin says Protected and Heritage Trees are regulated on residential property, and trees under 19 inches in diameter are not.
Hydraulic jack: The tool that pushes piles or piers into the ground and lifts the structure.
Hydrostatic test: A plumbing test that fills drain lines with water to see whether the level drops, which points to a leak.
International Residential Code (IRC): The model building code for one- and two-family homes adopted by many Texas cities. Texas engineering law references it for slabs on expansive soil (Occ. Code 1001.056(c)(2)).
Karst: Terrain formed by dissolving limestone, with sinkholes, caves and springs. Much of Florida and the Edwards Aquifer region of Texas are karst.
L/360: A deflection limit: the span length divided by 360. See Deflection.
Level A, B and C investigations: The three investigation levels in the ASCE Texas guidelines. Level A is a walk-through and interview. Level B adds relative floor elevations and a scaled drawing. Level C adds testing such as soil sampling and plumbing tests.
Lien affidavit: In Texas, the document a contractor files to claim a lien. On a homestead, it must state in bold: NOTICE: THIS IS NOT A LIEN. THIS IS ONLY AN AFFIDAVIT CLAIMING A LIEN (Property Code 53.254(f)).
Lifetime warranty: A repair company's promise, usually to adjust piers it installed if they settle, for the life of the structure or the owner. Terms vary widely. See lifetime transferable warranties.
Load-bearing wall: A wall that carries weight from above. Florida's sinkhole law treats leaning of load-bearing walls outside the middle third of the base as structural damage (627.706(2)(k)).
Foundation terms: M to N
Masonry veneer: Brick or stone on the outside of a wood-framed wall. It cracks easily when a slab edge moves.
Milestone inspection: A Florida structural inspection required under Fla. Stat. 553.899 for condominium and cooperative buildings of three or more habitable stories, due by the end of the year the building turns 30 (or 25 if the local agency sets that) and every 10 years after. See Miami and South Florida foundation problems.
Moisture barrier: A vertical sheet or barrier placed in the soil near a foundation to slow moisture changes under the slab. ASCE Texas lists it among non-structural measures.
Mudjacking: Pumping a cement-and-soil slurry under a sunken slab to raise it. Also called slabjacking. See slabjacking and polyurethane lifting.
Neutral evaluation: A Florida process for sinkhole disputes. It is nonbinding but mandatory if either side asks, and is run by an engineer or geologist certified by the Department of Financial Services. The insurer pays reasonable costs (627.7074).
Notice of claim: The written notice a Florida owner must serve under chapter 558 before a construction defect suit.
Notice of commencement: A Florida form an owner records before work starts. It is void if work does not begin within 90 days and generally expires after 1 year (713.13). For direct contracts over $5,000, a copy goes to the permit office before the first inspection (713.135).
Foundation terms: O to P
OP-H: The Texas Real Estate Commission's seller's disclosure form. The version on TREC's site is dated 2019, while Property Code 5.008 was last amended in 2023, so check that any form matches the current law.
Owner-builder: A Florida owner acting as their own contractor on a one- or two-family home for their own use (489.103(7)). Selling or leasing within a year raises a presumption of a violation.
Pier: A vertical support that carries a foundation's load to deeper or firmer soil. In pier-and-beam homes, short piers hold up the floor beams.
Pier and beam: A raised foundation where beams rest on piers over a crawl space. See pier and beam versus slab.
Pier cap: The block or plate on top of a pier where the foundation or beam rests.
Plasticity index (PI): A lab number showing how much a clay changes between plastic and liquid states. Higher PI usually means more shrink-swell. The Florida Building Code treats soil with a PI of 15 or more, plus other criteria, as expansive.
Plan stamping: Sealing engineering documents the engineer did not prepare or supervise. The ASCE Texas guidelines note Texas rules prohibit it.
Polyurethane foam lifting: Injecting expanding foam under a slab to lift it or fill voids. A lighter alternative to mudjacking.
Post-tension slab: A slab with steel cables (tendons) tightened after the concrete cures to squeeze it together and resist cracking.
Post-tension tendon: A steel cable inside a post-tension slab. Cutting one can be dangerous. ASCE Texas lists tendon stressing and post-tension cable testing among repair and testing items.
Pressed concrete piles: Short concrete cylinders stacked and pushed into the ground with a hydraulic jack under the foundation. See pressed concrete piles.
Professional engineer (PE): An engineer licensed by the state. In Texas, only licensed engineers may use titles like professional engineer (Occ. Code 1001.301).
Professional geologist (PG): A licensed geologist. Florida's sinkhole law requires sinkhole testing by a professional engineer or geologist with sinkhole expertise (627.706(2)).
Push pier: See Steel push pier.
PVR (potential vertical rise): An estimate of how much a clay soil could swell upward, used in Texas foundation design.
Foundation terms: R
Raveling: Soil slowly washing or falling downward into voids in limestone. Florida's definition of sinkhole activity includes raveling of soils into subterranean voids (627.706(2)(i)).
RCLA: The Texas Residential Construction Liability Act, Property Code chapter 27. It requires a 60-day certified-mail notice before suing a residential contractor, and it prevails over the DTPA where they conflict. See Texas RCLA.
Recharge zone: Where water enters an aquifer through exposed rock. The Edwards Aquifer recharge zone covers about 1,250 square miles of exposed Edwards Limestone, according to the Edwards Aquifer Authority.
Recovery Fund (Florida): The Florida Homeowners' Construction Recovery Fund, which can pay some homeowners who lose money due to specified violations by a licensed contractor (489.140 to 489.143).
Refusal: The point during pier or pile installation where the pier will not go deeper under the set force, meaning it has reached firm soil or rock or the structure's weight limit. Houston's 2026 permit training says plans need a pile note on refusal criteria or PSI.
Relative elevation: A floor height measured against one reference point in the house, not sea level.
Remediation documents: The engineer's repair plans and specifications. ASCE Texas lists 12 items they should include, such as a foundation plan, details and a post-repair survey requirement.
Repose (statute of repose): A hard deadline to sue that runs from completion, not discovery. Florida's is 7 years for construction claims (95.11(3)(b)); Texas generally allows 10 years (CPRC 16.009).
Retainage: Money an owner holds back. Texas requires owners to reserve 10 percent of the contract price during work and for 30 days after completion (Property Code 53.101).
Retaining wall: A wall that holds back soil. Austin exempts walls up to 4 feet from permits unless they support a surcharge or sit in a flood area. See retaining walls.
Root barrier: A vertical barrier in the soil that keeps tree roots away from a foundation.
Foundation terms: S
Seal: An engineer's official stamp. Texas plans and reports by a license holder must carry it (Occ. Code 1001.401(b)); Florida engineers must seal final plans and reports given to an owner (471.025).
Settlement: Downward movement of a foundation as soil compresses or loses support.
Shim: A thin piece of steel or hardwood placed between a pier and a beam or slab to fill a gap and set the height. ASCE Texas lists hardwood or steel shims for pier-and-beam repair.
Sill plate: The wood board that sits on top of a foundation wall or beam and anchors the wall framing.
Sinkhole: A closed depression in limestone or similar rock areas formed when surface sediments sink into voids made by dissolving rock. See sinkhole signs and testing.
Sinkhole activity: Florida's legal term for settlement or systematic weakening of the earth supporting a building, but only if caused by movement or raveling of soils into voids created by water acting on limestone or similar rock (627.706(2)(i)).
Sinkhole loss: Florida's legal term for structural damage to the covered building, including the foundation, caused by sinkhole activity (627.706(2)(j)). Optional coverage must be offered for an extra premium.
Slab-on-grade: A concrete foundation poured directly on the ground.
Slabjacking: See Mudjacking.
Soil boring: A hole drilled to sample soil layers for testing.
Spoil: Excavated soil. OSHA requires it to be kept at least 2 feet from the edge of an excavation (29 CFR 1926.651(j)(2)).
Steel push pier: Steel pipe sections driven into the ground with hydraulic jacks, using the weight of the house as resistance. See steel push piers.
Structural damage (Florida): For sinkhole claims, a list of specific conditions in 627.706(2)(k), such as foundation displacement beyond code tolerances with listed effects, leaning load-bearing walls, or risk of imminent collapse.
Structural component: Florida's term for any load-bearing member, including foundations, load-bearing walls, columns, beams and floors (489.105(15)).
Substantial completion: The point when work is done enough to use. Texas repose periods run from it, and ASCE Texas describes an engineer's letter of substantial completion after repair.
Substantial damage: A FEMA term. Damage where restoring the building would cost 50 percent or more of its pre-damage market value (44 CFR 59.1).
Subsidence: Sinking of the land surface. USGS says more than 80 percent of known U.S. land subsidence comes from groundwater use. Harris and Galveston counties have a subsidence district.
Subsidence incident: FGS's term for a reported ground depression that has not been verified as a true sinkhole.
Swale: A shallow ditch that carries water away. ASCE Texas recommends swale slopes of at least 1 percent, with 2 percent preferred.
Foundation terms: T to Z
Tilt: How far a foundation slopes overall from one side to another. ASCE Texas says tilt over 1 percent is usually noticeable.
TORA: Austin's Tree Ordinance Review Application, used when work affects regulated trees.
Trust funds (Texas): Construction payments to a contractor for work on Texas real property. The contractor is a trustee and may not divert them (Property Code 162.001, 162.031).
TREC REI 7-6: The Texas Real Estate Commission's inspection report form. Foundations are the first item under Structural Systems.
Underpinning: Adding supports, such as piers or piles, under an existing foundation to carry it to deeper or firmer soil. ASCE Texas says partial underpinning will not improve areas that are not underpinned.
Void: An empty space under a slab or in rock. Voids can come from soil washing out, leaks or dissolving limestone.
Watering program: Keeping soil moisture steady near a foundation during dry weather. ASCE Texas lists it as a non-structural measure. Austin Water allows foundation watering on assigned days.
Weep hole: A small opening in brick or a retaining wall that lets water drain out.
Terms people often mix up
| Terms | The difference |
|---|---|
| Settlement vs. heave | Settlement is the foundation going down; heave is it being pushed up, often by swelling clay or a leak. |
| Pier vs. pile | Often used loosely. A pile is usually driven or pressed; a pier is often drilled and poured. Read the plan for the exact type. |
| Sinkhole loss vs. catastrophic ground cover collapse | In Florida, sinkhole loss is optional coverage for structural damage from sinkhole activity; CGCC is mandatory coverage that requires abrupt collapse and a government order to vacate. |
| Inspection vs. engineering evaluation | A TREC inspection is a limited visual survey (22 TAC 535.227); an engineer's evaluation analyzes cause and repair. |
| Limitations vs. repose | A limitations period usually runs from when you discovered the problem; repose runs from completion and is a hard stop. |
| Notice of commencement vs. notice of claim | Both Florida terms: the first is recorded before work starts (713.13); the second is a pre-suit defect notice (558.004). |
| Mudjacking vs. polyurethane | Both lift slabs. Mudjacking pumps a cement slurry; polyurethane uses expanding foam. |
Related foundation repair contractors guides
- Which Foundation Repair Method Is Best? Piers, Piles, Slabjacking and Foam Compared
- What Are the Signs of Foundation Problems? The Complete Checklist, Inside and Out
- What Is a Foundation Elevation Survey, and How Do You Read Floor Level Readings?
- Expansive Clay Soil and Your Foundation: Why Do Texas Homes Move?
- Does Florida Homeowners Insurance Cover Sinkholes? Sinkhole Loss vs Catastrophic Ground Cover Collapse
- What Can You Do If Your New Texas Home's Foundation Is Cracking? Builder Warranties and the RCLA
- Slab vs Pier-and-Beam Foundations: What Is the Difference, and Which Holds Up Better?
- Which Foundation Cracks Are Normal and Which Are Serious?
Foundation repair contractors by state and city
Questions people ask
What does underpinning mean?
Underpinning means adding new supports under an existing foundation so its weight is carried to deeper or firmer soil or rock. Common types are pressed concrete piles, steel push piers, helical piers and drilled concrete piers. The ASCE Texas guidelines warn that partial underpinning will not improve how areas without new supports perform, so check which parts of the house a proposal actually covers.
What is refusal in pier installation?
Refusal is the point where a pier or pile will not go any deeper under the force being applied. It usually means the pier has reached dense soil or rock, or the force has reached the structure's weight. Engineers set refusal criteria, often as a pressure reading. Houston's 2026 permit training says foundation repair plans need a pile note on refusal criteria or PSI. Ask for a log of each pier's depth and pressure.
What is the active zone?
The active zone is the upper layer of soil whose moisture, and therefore volume, changes with wet and dry seasons. Soil below it stays more stable. Deep pier systems try to reach below it. Steady watering, good drainage and root control aim to limit moisture swings inside it so the slab moves less.
What is a post-tension tendon?
A post-tension tendon is a steel cable cast inside a slab, then pulled tight after the concrete cures to compress the slab and help it resist cracking. Tendons hold great force, so cutting or drilling into one without locating it first can be dangerous and damage the slab. The ASCE Texas guidelines list tendon stressing and post-tension cable testing among repair and testing options.
What is the difference between a sinkhole loss and a catastrophic ground cover collapse?
Both are Florida insurance terms. A catastrophic ground cover collapse requires an abrupt collapse, a visible depression, structural damage and a government order to vacate; every insurer must cover it. A sinkhole loss is structural damage caused by sinkhole activity, which insurers must make available for an extra premium as optional coverage. Settling or cracking alone does not count as a catastrophic ground cover collapse (627.706).
What is a shim?
A shim is a thin piece of steel or hardwood placed between a pier and the beam or slab above it to fill a gap and set the height. In pier-and-beam homes, re-shimming is a common, lower-cost repair when floors sag. In slab repair, steel shims are stacked on top of piers after lifting. Wood shims can rot or crush over time, so ask what material will be used.
What is a sill plate?
A sill plate is the wood board that sits on top of a foundation wall, beam or slab edge and anchors the bottom of the wall framing. In pier-and-beam and older homes, sill plates can rot from moisture or termites, which can look like foundation settlement. A Texas inspector reports deficiencies in sills as part of structural systems under 22 TAC 535.228.
Sources
- Fla. Stat. 627.706
- Fla. Stat. 627.707
- Fla. Stat. 627.7074
- Fla. Stat. 558.002
- Fla. Stat. 558.004
- Fla. Stat. 489.103
- Fla. Stat. 489.105
- Fla. Stat. 489.141
- Fla. Stat. 471.025
- Fla. Stat. 713.08
- Fla. Stat. 713.13
- Fla. Stat. 713.135
- Fla. Stat. 95.11
- Fla. Stat. 553.899
- Florida Building Code 2023, ch. 18 (UpCodes)
- Florida Geological Survey Sinkhole FAQ
- Florida Geological Survey Subsidence Incident Reports
- Texas Property Code ch. 27
- Texas Property Code ch. 5
- Texas Property Code ch. 53
- Texas Property Code ch. 162
- Texas Business and Commerce Code ch. 17
- Texas CPRC ch. 16
- Texas Occupations Code ch. 1001
- 22 Tex. Admin. Code 535.227
- 22 Tex. Admin. Code 535.228
- TREC REI 7-6 inspection form
- TREC OP-H seller's disclosure form
- ASCE Texas Section Residential Foundation Guidelines, Version 3 (2022)
- Houston Permitting Center: Foundation Repair
- Houston One-Stop Shop Residential Training (Feb. 2026)
- City of Austin: Work Exempt from Building Permits
- City of Austin: Trees on Residential Property
- Edwards Aquifer Authority: About the Edwards Aquifer
- TCEQ Edwards Aquifer Protection Program
- 44 CFR 59.1 (eCFR)
- OSHA 29 CFR 1926.651
- USGS: Sinkholes
- Harris-Galveston Subsidence District
This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.