Local Guide · Hurricane shutters and impact windows

What Is a Hurricane-Rated Garage Door? Wind Load vs. Impact Ratings, Bracing Kits and How to Read the Label

Why the garage door is the opening most likely to cost you your roof, the difference between wind-load (pressure) and impact ratings, ANSI/DASMA 108 and 115, how to read the label, what bracing kits can and cannot do, and how garage doors count on Florida and Texas insurance paperwork.

A hurricane-rated garage door is a door, track and hardware system tested to resist a specific design wind pressure, both inward and outward, and, if impact rated, a 9-pound 2x4 missile followed by pressure cycles. Pressure ratings use ANSI/DASMA 108, ASTM E330 or TAS 202; impact ratings use ANSI/DASMA 115 or TAS 201 and 203. The permanent label shows the rating in psf. If the door fails, wind can pressurize the house and lift the roof.

Key facts

  • IBHS says a garage door pushed in by high winds lets pressure build inside the home, pushing up on the roof and out on the walls, and calls a wind-rated garage door and re-roofing the two most significant ways to improve hurricane resilience.
  • TDI states that garage door failures contributed to 80% of home failures in recent hurricanes; TDI gives no study citation for the figure.
  • FBC 1709.5.2.1 requires sectional and rolling garage doors to be tested under ANSI/DASMA 108, ASTM E330 Procedure A or TAS 202 (TAS 202 in the HVHZ).
  • FBC 1709.5.2.1.1 requires a permanent garage door label showing the manufacturer, model, positive and negative design pressure, impact rating if any, installation drawing number, Florida or Miami-Dade approval number and test standards.
  • FBC 1609.1.2.3 requires glazed garage doors in wind-borne debris regions to meet an approved impact standard or ANSI/DASMA 115.
  • Per DASMA, wind load test pressure is commonly 1.5 times the design load, and the building department is the sole and final determiner of required pressures.
  • DASMA's inspection guideline says not to rely on a wind load label alone, because doors share components that can be configured in different ways.
  • Florida's 2026 mitigation form lists ANSI/DASMA 115 for Level A garage doors and rates verified pressure-only solid garage doors (ANSI/DASMA 108, ASTM E330 or TAS 202) as Level D.
  • My Safe Florida Home grants may pay for garage doors as opening protection when the program inspection recommends them (Fla. Stat. 215.5586).

Why is the garage door the most important opening to protect?

Because it is the biggest opening on most houses, it is made of thin panels that span a wide gap, and when it fails it lets the wind inside. The Insurance Institute for Business and Home Safety (IBHS) explains what happens next: a garage door pushed in by high winds lets pressure build inside the home, pushing up on the roof and out on the walls, often causing significant structural damage. IBHS calls installing a wind-rated garage door and re-roofing the two most significant ways to improve a home's hurricane resilience.

The Texas Department of Insurance goes further, stating that in recent hurricanes garage door failures contributed to 80% of home failures. TDI does not cite a study for that figure, so treat it as TDI's assessment rather than a measured statistic. FEMA's post-storm review in the U.S. Virgin Islands found that wind pressure failure of older sectional and rolling doors that were not manufactured to resist high wind loads is common.

The message from safety groups has shifted from "the garage door is your weakest opening" to "it can be your strongest." In a January 2025 statement reported by DASMA, the CEO of the Federal Alliance for Safe Homes (FLASH) said "a storm-ready garage door is your best and strongest defense." FLASH also cites a NIST study of about 3,000 homes in the 2011 Joplin tornado, in which homes with intact garage doors were 90% likelier to keep their roofs and the wall next to the garage. That is tornado data, not hurricane data, but it points the same way.

Wind-load rated vs. impact rated: what is the difference?

Wind-load (pressure) ratedImpact rated
What it resistsA uniform design pressure pushing in (positive) and pulling out (negative)The same pressures, plus a debris strike followed by thousands of pressure cycles
Test standardsANSI/DASMA 108, ASTM E330 (with DASMA 108 acceptance criteria), TAS 202ANSI/DASMA 115; TAS 201 and 203 in Florida
MissileNoneLarge missile: a 9-pound 2x4 at 50 ft/s (FORTIFIED's Large Missile D definition)
Required whereNearly everywhere a code applies (FBC 1709.5.2.1; IRC R609.4)Glazed garage doors in wind-borne debris regions (FBC 1609.1.2.3); all garage doors in the HVHZ (FBC 1626.1)
Florida mitigation formSolid door: Level DLevel A

DASMA's FAQ defines "impact rated" as garage doors and glazing that pass cyclic and impact test procedures such as those in ANSI/DASMA 115. A door can be wind rated without being impact rated. The rating applies to the whole tested system: door sections, reinforcing struts, hinges, rollers, tracks, track brackets and the fasteners into the jambs.

Do windows in the door change things? DASMA says the pressure requirement does not change because the door has glazing, but approvals specify the glazing type and how many sections have it. The glass itself is a glazed opening: in debris regions it must be impact rated, and Florida's mitigation form rates a garage door with glass in the glazed column, where an unprotected lite can make the whole house X. The U.S. Department of Energy's Building America guide, citing FEMA P-804, treats glazing above about 1 square foot on a one-car door or 1.8 square feet on a two-car door as needing both impact and pressure certification.

Positive and negative pressure on garage doors

DASMA explains that in a high wind event both positive and negative pressures act on a garage door: positive pressure tries to push the door into the building, and negative pressure tries to pull it out. Failures come in three forms, per the Building America guide: the door buckles outward under suction, buckles inward under positive pressure, or the hardware gives way and the door leaves its tracks.

Design pressure is not set by wind speed alone. DASMA lists the inputs: exposure category, enclosure category, topography, elevation, door location on the building, door size, the building code in force, mean roof height, building geometry and roof pitch. That is why DASMA says the industry cannot supply a door based only on a wind speed, and why a product claiming a "150 mph" rating tells you less than one rated +36/-40 psf. TDI warns that a product rated for "Force 12" winds only meets the minimum of a Category 1 hurricane (74 mph).

To show scale, DASMA's Garage Door Wind Load Guide (TDS 155, based on ASCE 7-98 to 7-05 and revised April 2026) lists these pressures for a 16 x 7 foot double door up to 30 feet mean roof height on an enclosed building:

Basic wind speed (ASCE 7-05 basis)Exposure B (suburban)Exposure C (open)
130 mph+25.6 / -28.5 psf+31.1 / -34.7 psf
140 mph+29.7 / -33.1 psf+36.1 / -40.2 psf
150 mph+34.1 / -38.0 psf+41.4 / -46.2 psf

These are reference values from an older edition of the wind standard, not your requirement; current codes use ASCE 7 ultimate wind speeds and different maps. DASMA states the local authority having jurisdiction is the sole and final determiner of required pressures. The point of the table is the pattern: pressures climb fast with wind speed, open exposure adds roughly 20%, and the negative (suction) number is always larger. Exposure D (flat land or open water) produces higher pressures still.

Do you need an impact garage door in Florida?

  • Miami-Dade and Broward (HVHZ): yes. FBC 1626.1 requires all outside doors to meet the impact criteria or be protected by an approved device, and garage doors must comply with TAS 202 for pressure. Miami-Dade requires a stand-alone permit (category 22) with the total area, an elevation of each wall, door sizes, and the approval number and current NOA for each door.
  • Wind-borne debris region elsewhere: glazed garage doors must meet an approved impact standard or ANSI/DASMA 115 (FBC 1609.1.2.3). Solid doors must meet the design pressure rating; impact protection for solid doors is not written into 1609.1.2, but it is what earns Level A on the mitigation form.
  • Replacement: FBC Existing Building 707.4 requires replacement garage doors to be designed and built to comply with FBC Chapter 16, and Florida's labeling rule applies to every new garage door.
  • Approvals: Florida law requires product approval for exterior doors, and garage doors carry a Florida approval or Miami-Dade NOA. Miami-Dade accepts either for permits.

A sample Miami-Dade NOA for a steel sectional door with window lites shows how specific approvals are: it lists the door as rated DP +27.0, -30.0 psf, approves large and small missile impact only without flood vents, and states that "garage doors with flood vents are not rated for Large Missile Impact Resistance." If your garage has flood vents in the door, that door may not count as impact protection.

Texas: garage doors and windstorm certification

TDI says Texas garage doors must be tested to ASTM E330, glass panels should be rated to ASTM E1996, and impact protective systems must also be tested to ASTM E330. TDI recommends an impact-resistant garage door if the door has glass panels, and offers two options for strengthening garage doors: replace the door and track with a system designed for high winds and debris, or use a tested and approved impact-resistant covering.

In the TDI catastrophe area (14 coastal counties plus parts of Harris County east of State Highway 146), TWIA lists garage doors among improvements that need a windstorm Certificate of Compliance. File Form WPI-1 before work; TDI inspectors charge no fee and must inspect during installation. TDI publishes product evaluations, including garage door evaluations, on its Windstorm System. Since April 1, 2026, work is certified to the 2024 IRC or IBC. Do not pay in full until the WPI-8 is issued. Houston, Dallas, San Antonio and Austin homes outside the catastrophe area follow local codes only. See TWIA windstorm certification.

How to read a garage door wind load label

Florida's code (FBC 1709.5.2.1.1) requires a permanent label provided by the manufacturer showing:

  • The manufacturer
  • The model or series number
  • The positive and negative design pressure rating, in psf
  • Whether it is impact rated
  • The installation instruction (wind load) drawing reference number
  • The Florida product approval or Miami-Dade approval number, if applicable
  • The test standards

The label may use a checklist format for the components needed to assemble the approved system; the installer or manufacturer must mark the selected components. Miami-Dade NOAs for garage doors place the label on the door's side track, bottom angle or the inner surface of a panel. DASMA says the code requires design pressure in psf on the label, not a wind speed.

Example reading

A label reading "+38.0 / -43.0 PSF, impact rated, ANSI/DASMA 115, drawing 12-345, FL 00000" means the door system, built per drawing 12-345, is rated to resist 38 psf pushing in and 43 psf pulling out, has passed impact testing, and holds the listed Florida approval. Compare both numbers with the pressures required for your door's size and location.

Do not rely on the label alone

DASMA's code inspection guideline (TDS 181) tells inspectors not to rely on a wind load label alone, because garage doors are site-installed products that share components which can be configured in different ways. Its checklist compares the installed door with the wind load drawing: door size not larger than the drawing, reinforcement (struts) in the right number, size and location, stile type and count, hinge and roller type and count, roller retainers, a lock on manually operated doors that require one, track bracket type, quantity and fastener spacing, glazing type, vertical posts if required, and jamb-to-structure fasteners and edge distances. DASMA also notes the supporting structure (the jambs and wall) is the builder's or designer's responsibility, not the door installer's.

What are ANSI/DASMA 108 and 115?

DASMA, the Door and Access Systems Manufacturers Association, writes the national test standards for garage doors.

  • ANSI/DASMA 108 sets the test method and acceptance criteria for sectional garage doors and rolling doors under uniform static air pressure. It is the pressure (wind load) standard. The Florida code accepts DASMA 108, ASTM E330 Procedure A with DASMA 108 acceptance criteria, or TAS 202. Under ASTM E330, products are tested to 1.5 times the design pressure, and DASMA says test load is commonly 1.5 times the design load. DASMA 108 requires the positive and negative test pressures on the test report; Building America notes that if the label does not show the pressure rating, consult the test report form.
  • ANSI/DASMA 115 covers sectional, rolling and flexible doors under missile impact and cyclic wind pressure. The 2023 Florida Building Code references the 2005, 2012 and 2017 editions.

FEMA's Virgin Islands advisory noted that some fire station doors labeled to Florida test standards rather than DASMA 115 failed, and stated that DASMA 115 is more stringent than the applicable Florida test standards. That observation came from one site; Florida's code and mitigation form accept both, but it is a reason to read the label and approval closely.

DASMA also explains that manufacturers may rate untested sizes by engineering: a narrower door than the tested one may carry a higher rating, and a wider one a lower rating, using rational analysis (TDS 180). DASMA cites Florida's product approval rule allowing evaluation reports signed and sealed by a Florida-registered architect or engineer based on tests or rational analysis.

Can you brace an existing garage door? Are bracing kits approved?

Sometimes, but only certain ways count. The Building America guide, summarizing FEMA P-804 retrofit guidance, gives these options:

  • Door with little or no glass (1 sq ft or less on a one-car door, 1.8 sq ft or less on a two-car door): install a door certified for the design wind pressure, or add an impact-resistant covering that protects the entire door and is certified for the design wind pressure.
  • Door with larger glazing: install a door certified for both missile impact and design wind pressure, or add an impact-resistant covering certified for design pressure.
  • Reinforcement kits: aftermarket kits may provide vertical and horizontal reinforcement. If the kit requires adjusting spring tension, a professional should do it, because springs and cables are under extreme tension. DASMA warns inspectors not to touch spring components.

Approval status matters. In Florida, a product marketed as hurricane protection must be approved (Florida Statutes 553.842). A bracing kit or post system counts toward code compliance or insurance credit only if the door-and-kit combination, or the kit itself, is covered by a product approval and installed per its drawings. Florida's mitigation form gives Level A or D credit only to verified products meeting its listed standards; a home-made brace will most likely be marked unverified. Temporary vertical posts that brace a door from inside during a storm may help, but check whether the system is approved for your door model before relying on it for anything but extra margin.

Retrofit details, including when to replace the track, are in garage door bracing and retrofits.

Can you put a screen or shutter over the garage door?

Yes. Approved impact screens and roll-down shutters for garage openings exist, and the code accepts an impact-resistant covering instead of an impact door. FORTIFIED's 2025 standard allows a pressure-rated garage door with windows to be protected by an impact-rated cover instead of being impact rated itself. Two cautions:

  • The door behind the cover still needs its pressure rating. FORTIFIED requires all garage doors to be pressure rated for the Hurricane designation, with or without windows.
  • The covering must be approved for the opening size and mounted per its approval, and you must be able to deploy it before the storm. Large fabric screens need clearance so they do not hit the door when struck.

FORTIFIED garage door requirements

The 2025 FORTIFIED Home standard from IBHS, used by some Florida and Texas insurers for discounts, sets these minimums for garage doors:

Garage door typeFORTIFIED Hurricane / SilverFORTIFIED High Wind / Silver
With windowsPressure rated and impact rated, or pressure rated and protected by an impact-rated coverPressure rated
Without windowsPressure ratedPressure rated

Pressure ratings must meet or exceed design pressures for Exposure C minimum and a design wind speed of at least 130 mph (Vult), for the door's size and location. For garage doors, FORTIFIED accepts ANSI/DASMA 108 or ASTM E330 for doors with no glazing and ANSI/DASMA 115 for doors with glazing, and ANSI/DASMA 115 for impact. See IBHS FORTIFIED and opening protection.

Does a new garage door count on the wind mitigation form?

Yes. Question 9 of Florida's 2026 form (OIR-B1-1802 Rev. 04/26) includes garage doors in two columns:

  • Glazed garage doors are rated with the other glazed openings. Level A requires ANSI/DASMA 115 (for garage doors) and a listing in the Florida or Miami-Dade approval system. An unprotected glazed garage door can drop the whole house to X.
  • Solid garage doors are non-glazed openings. Level A if impact rated; Level D if verified for wind pressure only (ASTM E330, ANSI/DASMA 108 or PA/TAS 202). A Level D garage door on a house whose windows are all Level A gives sub-answer A.2 instead of A.1.

The form needs a photo or document proving each attribute, so photograph the label and keep the approval. Citizens tells policyholders who add features to submit documentation such as NOA letters and says a new inspection may be required. A damaged garage door that needs repair is marked Z, which disqualifies the home from all mitigation rate differentials. See the wind mitigation form.

How to check a garage door's rating when there is no label

  1. Look everywhere. Labels may be on the side track, the bottom angle, the inside face of a panel or the end stile. Clean gently; do not peel.
  2. Check the permit file. Garage door replacements need permits in most of Florida (Tampa requires one even after a declared disaster). The permit drawings usually list the model and approval number.
  3. Identify the model. Look for a manufacturer name and model or production code stamped on the door, and search the Florida product approval database or Miami-Dade's Product Control Search under Doors, subcategory Sectional or Rollup.
  4. Compare with the drawing. Once you find a candidate approval, compare the struts, hinges, track brackets and glazing with its wind load drawing, the way DASMA's inspection checklist does.
  5. Ask the manufacturer for the test report form. DASMA 108 requires test pressures to be recorded there.
  6. If nothing matches, assume the door is unrated for insurance purposes and plan a replacement or an approved retrofit.

How much does a hurricane-rated garage door cost?

We found no reliable, dated, independent cost study for wind-rated or impact-rated garage doors in Florida or Texas, so we do not quote an average. The 2025 Cost vs. Value report's garage door project describes a 16 x 7 foot, four-section, R-12 insulated steel door on new heavy-duty galvanized tracks, but it is not a wind-rated specification and its figures were not available to us. A FLASH survey reported by DASMA found 34% of respondents would spend $500 to $1,000 on an upgraded door, which tells you about expectations, not prices.

What raises the price: higher design pressure (more struts, heavier gauge steel, more hinges and track brackets), impact rating, impact glazing, insulation, double width, custom finishes, new tracks and springs, jamb repair, and permits. Unincorporated Miami-Dade's minimum residential permit fee is $150.82 under its October 2026 schedule. Tampa waives the permit fee, but not the permit, for storm-related garage door replacement while the Mayor's emergency powers are in effect.

Florida's My Safe Florida Home program can pay for garage doors as opening protection when its inspection recommends them, matched $2 state to $1 homeowner up to $10,000 (no match for low-income applicants). The MSFH portal has been offline since November 10, 2026. See My Safe Florida Home.

How to choose a provider

  • Find the label and photograph it; record the positive and negative design pressure.
  • Find out the design pressure your door needs from your building department or installer.
  • In Miami-Dade and Broward, or for any door with windows in a debris region, choose an impact-rated door (ANSI/DASMA 115 or TAS 201/203).
  • Get the Florida approval or NOA number and the wind load drawing for the exact door size and options.
  • Check that struts, hinges, track brackets and jamb fasteners match the drawing after installation.
  • Avoid flood-vented doors if you need large missile impact credit, unless the approval covers them.
  • Do not adjust springs yourself; hire a trained technician.
  • Use only approved bracing or covering systems if you retrofit.
  • Get the permit (and in Texas coastal counties, the WPI-8) and keep the paperwork for your mitigation inspection.
  • Before each storm, lock manual doors, check tracks and fasteners, and deploy any approved bracing or covering.

Related hurricane shutters and impact windows guides

Hurricane shutters and impact windows by state and city

Questions people ask

What does a garage door wind load rating of +30/-34 mean?

It means the door system is rated to resist a design pressure of 30 pounds per square foot pushing inward and 34 pounds per square foot pulling outward. It was tested to higher loads, commonly 1.5 times the design pressure. Both numbers must meet or exceed the pressures your building department requires for that door's size and location.

Is a wind-rated garage door the same as an impact-rated one?

No. A wind-rated door has passed pressure testing, such as ANSI/DASMA 108 or ASTM E330. An impact-rated door has also passed a missile impact and cyclic pressure test, such as ANSI/DASMA 115. In Florida's HVHZ, garage doors must meet impact criteria. On the mitigation form, a solid wind-rated door is Level D and an impact-rated door is Level A.

Do windowed garage doors need impact glass?

In Florida's wind-borne debris regions and the HVHZ, yes: glazed garage doors must meet an approved impact standard or ANSI/DASMA 115. TDI says glass panels in Texas garage doors should be rated to ASTM E1996 and recommends an impact-resistant door if it has glass. An unprotected garage door window can lower your whole home's mitigation rating.

Can I make my old garage door hurricane-ready?

Possibly, with an approved retrofit. FEMA P-804 guidance, summarized by the U.S. Department of Energy, lists replacing the door with a certified one, adding a certified impact-resistant covering, or using aftermarket reinforcement kits. For code and insurance credit, the retrofit must be approved and installed per its drawings. Spring adjustments should be done by a professional.

Why are negative pressure ratings higher than positive ones?

Suction on the outside of a building, especially near corners and edges, is usually stronger than the inward push. DASMA's wind load tables show the negative value larger than the positive value at every wind speed and exposure. Both must be met, so check the larger negative number carefully.

Does a hurricane garage door lower my insurance?

It can. Florida law requires insurers to offer discounts for opening protection, and a garage door affects your opening protection answer on the mitigation form. The effect depends on your other openings and your insurer's rating plan. Ask your agent what changes if your garage door moves from unverified to Level D or Level A.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration