Design Pressure (DP) Ratings Explained: What Do DP50 and +60/-70 psf Mean for Your Windows?

How window, door and shutter design pressure ratings work, why corners and waterfront homes need higher numbers, and how to check a product against the Florida Building Code and Texas windstorm rules.

A design pressure (DP) rating is the wind load, in pounds per square foot, a window, door or shutter is approved to resist, given as a positive (push) and negative (suction) value. DP50 means +50/-50 psf. Your required DP depends on your design wind speed, whether the opening is in a corner zone, its size, your mean roof height and your exposure category. Every product's rating must meet or exceed the required pressure for its specific opening.

Key facts

  • FBC 1709.5.1 requires window and door labels to show positive and negative design pressure, maximum size tested, impact rating and the Florida or Miami-Dade approval number.
  • FBC 1609.1.2.4.1 tests shutters at 1.5 times the design pressure; FBC 1709.5.2 tests assemblies for 10 seconds at 1.5 times the design pressure.
  • FBC Residential Table R301.2(2), 160 mph, 10 sq ft, Exposure B, 30 ft: Zone 4 is +27.6/-30.0 psf and Zone 5 (corner) is +27.6/-37.0 psf.
  • The FBC Residential zone figure sets the corner strip width a at 4 feet in all cases.
  • Height and exposure multipliers at a 15 ft mean roof height: 0.82 (B), 1.21 (C), 1.47 (D) (FBC Residential Table R301.2(3)).
  • The 8th Edition (2023) Florida Building Code references ASCE 7-22; under it, wind speeds changed only in the Panhandle (Florida Building Commission fact sheet, June 2024).
  • The ATC Hazards by Location site cannot be used for site-specific wind speeds under the 8th Edition FBC; use the ASCE 7 Hazard Tool.
  • HVHZ Risk Category II design wind speeds: 175 mph in Miami-Dade, 170 mph in Broward (FBC 1620.2); HVHZ buildings are Exposure C unless D applies (FBC 1620.3).
  • Texas windstorm certification uses the 2024 IRC or IBC since April 1, 2026, with wind speed set per structure (TDI).

What is a design pressure rating?

A design pressure (DP) rating is the wind pressure a window, door, skylight or shutter is rated to handle, stated in pounds per square foot (psf). It is written as a pair of numbers: a positive number for wind pushing in on the glass, and a negative number for wind pulling the unit outward. A label that reads +50/-50 psf means the product is rated for 50 pounds of push and 50 pounds of pull on every square foot of its surface.

That sounds small until you multiply it out. A 3-foot by 5-foot window has 15 square feet of area. At 50 psf, the wind load on that one window is 750 pounds, pulling on the frame, the glass and every anchor that holds it in the wall. A 16-foot-wide sliding glass door at the same pressure carries several tons.

Design pressure is not the same as impact resistance. DP tells you how much steady and gusting wind pressure a unit can take. Impact resistance tells you whether it survives being hit by flying debris and then cycled with pressure. A product can have a high DP and no impact rating. In a windborne debris region you need both. See our missile impact testing guide for the impact side.

Where the rating comes from

The Florida Building Code, Section 1709.5.1, requires exterior windows and sliding doors to be tested and labeled to AAMA/WDMA/CSA 101/I.S.2/A440 or TAS 202 (in the High-Velocity Hurricane Zone, TAS 202 plus ASTM E1300 or Section 2404). Doors and assemblies not covered there are tested to ASTM E330 or TAS 202 under Section 1709.5.2, and "each assembly shall be tested for 10 seconds at a load equal to 1.5 times the design pressure." The required label must show the "positive and negative design pressure rating," the maximum size tested, any impact rating and the Florida or Miami-Dade approval number.

What does DP50 or +60/-70 psf mean?

"DP50" is industry shorthand for a design pressure of 50 psf. When a product's push and pull ratings differ, it is written out, such as +60/-70 psf. In that case the unit is rated for 60 psf pushing in and 70 psf pulling out. Both numbers matter, and you must check each against what your opening needs.

Label readingPushing in (positive)Pulling out (negative)Load on a 15 sq ft window (pull side)
DP30 (+30/-30)30 psf30 psf450 lb
DP50 (+50/-50)50 psf50 psf750 lb
+60/-7060 psf70 psf1,050 lb
+80/-9080 psf90 psf1,350 lb

The load column is simple multiplication (pressure times area) to show scale. It is not a code calculation.

Ratings change with size

The same product line often carries different ratings at different sizes. A small unit may be rated much higher than the largest size of the same series. FBC 1709.5.1 allows sizes other than the tested size to carry different pressures only when set by "accepted engineering analysis such as AAMA 2502 or WDMA I.S.11," with limits on frame area and other checks. That is why the approval documents usually show a table of sizes and pressures, not one number. Read the row for the size you are buying.

Allowable (ASD) vs. ultimate pressures

Product ratings are allowable stress design (ASD) values. FBC 1709.5 says the required design pressure for windows and doors "shall be determined using the allowable stress design load combinations." Wind speed maps in the code use ultimate design wind speeds (Vult). The code bridges the two with a 0.6 factor: FBC 1609.1.3 lets loads from ASCE 7 be multiplied by 0.6 for wind-load testing, and the FBC Residential pressure tables note that "table values include the 0.6 load reduction factor." The practical point is simple: compare the product's DP with ASD pressures, which is what the residential tables give you. Do not compare a DP rating to an ultimate pressure without the conversion.

Why are positive and negative pressures different?

Wind does not just push on the side of a house that faces the storm. As air flows around the corners and over the roof, it speeds up and creates suction on the side walls, the back wall and the roof. That suction is the negative pressure. At the corners of walls and the edges of roofs, the flow separates sharply and the suction peaks. That is why the code's tables show larger negative numbers than positive ones in the corner zone.

The FBC Residential Table R301.2(2) shows this clearly. For a wall at a 160 mph design wind speed and a 10 square foot window, the interior wall zone (Zone 4) is +27.6/-30.0 psf, while the corner zone (Zone 5) is +27.6/-37.0 psf. The push is the same, but the pull at the corner is about 23 percent higher.

Negative pressure is what pulls windows out of walls and sucks shutters off their tracks. When an opening fails outward, the home's envelope is breached just as surely as when glass breaks inward. IBHS explains that once wind gets inside through a broken window, internal pressure pushes up on the roof and out on the walls. Getting the negative rating right is as important as the positive one.

Do corners of the house need higher DP? (Zones 4 and 5)

Yes. The code splits walls into two zones:

  • Zone 4 is the main field of the wall, away from the corners.
  • Zone 5 is the end zone near each outside corner. In the FBC Residential simplified method, the figure that maps these zones (Figure R301.2(7)) notes that the corner strip width "a = 4 feet in all cases."

Any window, door or skylight that falls inside a Zone 5 strip must meet the higher Zone 5 pressure. In a typical ranch house, that often means the windows closest to each corner of the house, the corner of a garage, and sliding doors that sit near the end of a wall.

Zone 4 and Zone 5 pressures from the Florida Building Code

These values come from FBC Residential Table R301.2(2), for a 10 square foot window, a mean roof height of 30 feet, Exposure B. They are ASD pressures in psf.

Design wind speed (Vult)Zone 4 (wall field)Zone 5 (wall corner)
130 mph+18.2 / -19.8+18.2 / -24.4
140 mph+21.2 / -22.9+21.2 / -28.3
150 mph+24.3 / -26.3+24.3 / -32.5
160 mph+27.6 / -30.0+27.6 / -37.0
170 mph+31.2 / -33.8+31.2 / -41.8
180 mph+35.0 / -37.9+35.0 / -46.8

Those numbers are only the starting point. You must adjust them for height and exposure, which can raise them a lot, as the next sections show.

Effective wind area: bigger openings get slightly lower pressure per square foot

The table also varies by "effective wind area." For a Zone 5 opening at 160 mph, the pressure is -37.0 psf at 10 square feet, -34.5 at 20, -31.2 at 50 and -28.7 at 100 square feet. Large units average out the gust peaks over more area, so the per-square-foot demand drops a little. But the total force on a large unit is still much higher because it has more area. The code note says the effective wind area equals the span length times an effective width that may be taken as at least one-third of the span.

Zone 5 at 160 mph, Exposure B, 30 ftPressure (psf)
10 sq ft+27.6 / -37.0
20 sq ft+26.4 / -34.5
50 sq ft+24.7 / -31.2
100 sq ft+23.5 / -28.7

What are exposure categories (B, C and D), and what is Exposure C vs. D?

Exposure describes how rough the ground is upwind of your house. Rough ground, like a neighborhood full of houses and trees, slows the wind near the ground. Smooth ground, like open water, lets it hit at full force. The FBC Residential (Section R301.2.1.4) defines three surface roughness types and three exposure categories:

CategoryWhat the code describesTypical Florida or Texas setting
Exposure BUrban and suburban areas, wooded areas, or terrain with numerous closely spaced obstructions the size of single-family homes or larger, prevailing upwind at least 1,500 feet (for mean roof heights of 30 feet or less)An inland subdivision surrounded by other homes
Exposure CApplies "for all cases where Exposures B or D do not apply." Surface roughness C is open terrain with scattered obstructions generally under 30 feet, such as flat open country and grasslandsHomes facing a golf course, open field, large lot or farmland; a house within 100 feet of a big open area
Exposure DFlat, unobstructed areas and water surfaces prevailing upwind for at least 5,000 feet or 20 times the building height, plus sites within 600 feet (or 20 times the height) of such a conditionBeachfront, bayfront and lakefront homes with open water upwind

Two details catch people. First, the code says that a building in rougher, B-type terrain still gets Surface Roughness C if it is within 100 feet of an open area of C or D terrain that extends more than 600 feet upwind and is wider than 150 feet. A home on the edge of a large retention lake, an open park or a golf course can land in C even inside a subdivision. Second, the code says "for a site located in the transition zone between categories, the category resulting in the largest wind forces shall apply."

The HVHZ rule

In Miami-Dade and Broward counties, FBC 1620.3 treats all buildings as Exposure C unless Exposure D applies. Exposure B is not used in the HVHZ. That is one reason window pressures in South Florida tend to be higher than in inland neighborhoods elsewhere in the state.

Why Exposure D at the beach matters so much

The height and exposure coefficients in Table R301.2(3) show the jump. At a 15-foot mean roof height the multiplier is 0.82 for Exposure B, 1.21 for Exposure C and 1.47 for Exposure D. That means a beachfront house in Exposure D faces window pressures about 79 percent higher than the same house in Exposure B (1.47 divided by 0.82). Many online guides skip this, which is how homeowners on the water end up with windows rated for an inland lot.

Does mean roof height matter?

Yes. Wind speed increases with height above the ground, so taller buildings see higher pressures. The code uses the mean roof height, which for most sloped roofs is roughly the average of the eave height and the ridge height. Table R301.2(3) of the FBC Residential gives these multipliers:

Mean roof heightExposure BExposure CExposure D
15 ft0.821.211.47
20 ft0.891.291.55
25 ft0.941.351.61
30 ft1.001.401.66
35 ft1.051.451.70
40 ft1.061.491.74
45 ft1.101.531.78
50 ft1.131.561.81
55 ft1.161.591.84
60 ft1.191.621.87

The tables in the FBC Residential simplified method apply to buildings with mean roof heights of 60 feet and less, as the Florida Building Commission's ASCE 7-22 fact sheet notes. Taller buildings, such as condo towers, need a full ASCE 7 calculation by an engineer. Miami-Dade, for example, now asks for wind calculations for all openings under FBC 1620 and ASCE 7-22 Chapter 30 when windows or doors are installed in threshold buildings (buildings over three stories or over 50 feet tall).

Elevated coastal homes

ASCE 7-22 added new provisions for elevated buildings, including loads on the underside of homes raised on piles, according to the Florida Building Commission fact sheet. Raising a home also raises its mean roof height, which pushes window pressures up. If you are building or rebuilding on pilings in Galveston, Port Aransas, the Panhandle or the Keys, expect an engineer's calculation rather than a table lookup.

Worked examples: how to estimate the DP you need

These examples use the FBC Residential tables to show the method. They are for learning, not for your permit. Your contractor or engineer must calculate the real numbers for your site, and the building department has the final say.

Example 1: inland subdivision vs. lakefront vs. beachfront

Assume a one-story home with a 15-foot mean roof height, in an area the map shows at 160 mph, with a 20 square foot window near a corner (Zone 5). The base value from Table R301.2(2) is +26.4/-34.5 psf.

SettingExposureMultiplierRequired pressure (psf)Does a DP50 window work?
Inland subdivisionB0.82+21.6 / -28.3Yes
Edge of open field or golf courseC1.21+31.9 / -41.7Yes
Open water upwindD1.47+38.8 / -50.7No. -50.7 exceeds 50

The same window, same house, same wind speed. Only the view changed, and the DP50 window stopped passing at the corner. The same unit in the middle of that wall (Zone 4, -28.7 psf base) would need -42.2 psf in Exposure D, so it would pass there.

Example 2: a two-story home at a higher wind speed

Assume a two-story home with a 30-foot mean roof height in an area mapped at 180 mph, Exposure C, and a 10 square foot corner window. The base is +35.0/-46.8 psf. Times 1.40 gives about +49.0/-65.5 psf. That window needs a rating of at least +49/-66, so a product labeled +60/-70 would work, but DP50 would not.

Example 3: Miami-Dade

Miami-Dade's Risk Category II design wind speed is 175 mph under FBC 1620.2, and the HVHZ uses Exposure C unless D applies. As a rough illustration only, using the residential table values between 170 and 180 mph and the Exposure C multipliers, corner windows on a typical two-story home can need negative ratings in the 60s psf or higher. Miami-Dade requires the permit plans to show "the required positive and negative pressures of each window/door," so these numbers will be on your permit, not guessed by a salesperson.

Garage doors use their own table

FBC Residential Table R301.2(4) lists garage door loads for a 30-foot mean roof height in Exposure B. A 16-by-7-foot door is +23.3/-26.0 psf at 160 mph and +29.3/-32.6 psf at 180 mph, before height and exposure adjustment. The table note says negative pressures assume the door has 2 feet of width in the building's end zone. See our garage door guide.

How does design pressure relate to wind speed?

Wind pressure grows much faster than wind speed. The code tables show it: for a Zone 5 corner window of 10 square feet, the negative pressure goes from -24.4 psf at 130 mph to -46.8 psf at 180 mph. A 38 percent increase in wind speed nearly doubles the pressure. That is because pressure rises roughly with the square of wind speed.

Ultimate vs. nominal wind speed

Florida maps show ultimate design wind speeds (Vult), measured as 3-second gusts. Some older product literature and documents use nominal or ASD wind speeds (Vasd). FBC Residential Table R301.2.1.3 converts between them:

Vult (mph)110120130140150160170180190200
Vasd (mph)8593101108116124132139147155

If a brochure says a window is "good to 150 mph," ask which kind of wind speed, at what exposure, height, zone and size. A wind speed claim without those details tells you little. Design pressure is the number that the code checks.

Wind speed is not hurricane category

Code design wind speeds are 3-second gusts used for engineering. Hurricane categories are based on sustained winds. The two are not directly interchangeable, so a "Category 5 rated" claim is marketing, not a code rating. The Texas Department of Insurance warns that products rated for "Force 12" winds only meet "the very minimum of a category 1 hurricane (74 mph)."

What is ASCE 7, and which edition applies?

ASCE 7 is the national standard "Minimum Design Loads and Associated Criteria for Buildings and Other Structures," published by the American Society of Civil Engineers. It contains the wind speed maps, exposure rules, pressure coefficients and zone layouts that building codes use. The window, door and shutter pressures in the Florida Building Code are built on it.

Florida: ASCE 7-22 in the 8th Edition (2023)

The Florida Building Commission's June 2024 fact sheet states that "the 8th Edition (2023) Florida Building Code has been updated to reference ASCE 7-22," and the FBC Building's referenced standards chapter lists ASCE/SEI 7-22. The 8th Edition took effect December 31, 2023. The 9th Edition (2026) is set to take effect December 31, 2026, according to DBPR.

The fact sheet lists what changed with ASCE 7-22:

  • Wind speeds changed only in the Panhandle. For Risk Categories I, II and III, speeds increased in the western Panhandle. For Risk Category IV, they increased in the western Panhandle and decreased slightly in the Big Bend. Peninsula wind speeds "are unchanged and effectively have not changed since the 2010 FBC."
  • Revised roof pressures for gable and hip roofs steeper than 7 degrees (generally lower for many roof zones).
  • New criteria for elevated buildings.
  • New tornado loads.
  • Slight changes to velocity pressure coefficients for Exposure B at mean roof heights of 40 feet or more.

If you live in Pensacola, Navarre, Fort Walton Beach, Destin or nearby, a window that was fine for a permit in 2022 may not meet today's pressures for the same house. Check before you reorder a matching unit.

Texas

Since April 1, 2026, Texas windstorm certification applications (Form WPI-1) for the coastal catastrophe areas must be certified to the 2024 International Residential Code or the 2024 International Building Code, according to TDI. TDI says the required wind speed "must be determined for each structure based on the location of the structure," using tools such as the ASCE 7 Hazard Tool, and that most designated catastrophe areas are now inside the windborne debris region. In Houston, Dallas, San Antonio and Austin, the city's adopted code edition and local amendments control; ask your building department which edition and wind speed it uses.

What is the ultimate design wind speed for my county, and how do I look it up?

The code sets the speed by location and by risk category. Risk Category II covers ordinary homes and most buildings. FBC Section 1609.3 tells you to use Figure 1609.3(1) for Risk Category II, Figure 1609.3(2) for Category III and Figure 1609.3(3) for Category IV, which includes essential facilities such as hospitals with emergency treatment, fire, police and emergency shelters.

Use the ASCE 7 Hazard Tool, not the old ATC site

This is a common mistake, even among professionals. The Florida Building Commission's fact sheet says the ATC Hazards by Location website, long used in Florida, provides wind speeds only for ASCE 7-16, 7-10 and 7-05 and "will not be updated to support ASCE 7-22." Because the 8th Edition FBC references ASCE 7-22, the fact sheet says the ATC site "cannot be used to obtain site-specific wind speeds" as of December 31, 2023. A new note on Figure 1609.3(1) allows site-specific speeds from the ASCE Wind Design Geodatabase (the ASCE 7 Hazard Tool) or equivalent. Florida's 2026 wind mitigation form also points inspectors to ASCE 7-22 Risk Category 2 speeds at ascehazardtool.org.

Known values and where to check

PlaceRisk Category II design wind speedSource
Miami-Dade County (HVHZ)175 mphFBC 1620.2
Broward County (HVHZ)170 mphFBC 1620.2
City of Sebastian (Indian River County)160 mph, by city ordinance O-12-08City of Sebastian
Bay County (Panama City area)Varies across the county; the county's 2023 FBC map shows 130 mph and 140 mph contours plus a 1-mile debris stripBay County wind-borne debris map
Any other Florida siteLook up by addressASCE 7 Hazard Tool; county building department
Texas coastal catastrophe areasDetermined per structureTDI; ASCE 7 Hazard Tool

The Florida Building Commission fact sheet also points to county-level maps developed by the University of Florida for all 67 counties and all four risk categories. It cautions that the maps are for information and that local jurisdictions often modify them, so "contact the applicable local jurisdiction for wind speeds for a specific site." Sebastian is an example: its adopted speeds come from a city ordinance.

For more on which areas need impact protection, see our Florida opening protection rules.

Who calculates the design pressure for my openings?

For a new home, the designer or engineer of record calculates component and cladding pressures and puts them on the plans. For a replacement project, the answer depends on the job:

  • Same-size replacement on a one- or two-family home or townhouse in Florida. FBC 107.1.1 says sealed drawings are not required if the units are installed per the manufacturer's instructions for the wind zone, meet current FBC Residential design pressures, are the same size in the same opening, and the instructions are filed with the permit. The contractor usually determines the pressures from the residential tables or a wind load calculator.
  • New or enlarged openings, structural changes or complex homes. Expect sealed drawings or calculations from a Florida-licensed engineer or architect.
  • Threshold buildings (over three stories or over 50 feet tall). Miami-Dade now requires wind calculations for all openings, wood buck calculations where bucks are 1-1/2 inches or thicker, and a threshold inspection by a certified Special Inspector, following a binding interpretation ratified by the Florida Building Commission on January 26, 2026. Miami-Dade says this applies throughout Florida.
  • Texas coastal homes. The TDI-appointed inspector or Texas-licensed engineer certifying the work for TWIA eligibility checks that products meet the adopted code pressures.

What is a wind load chart or calculation for a permit?

A wind load chart (sometimes called a window schedule) lists each opening on the house, its size, its zone (4 or 5, or a roof zone for skylights), and the required positive and negative pressures. Next to that, it lists the product chosen and its rated pressures from the approval. Miami-Dade asks for the required pressures for each unit on the plans, with the glass type and options picked from the approval's glass schedule. A good chart makes the inspector's job easy and protects you: if every product rating meets or beats every required pressure, the job is right on paper.

OpeningSizeZoneRequired (psf)Product rating (psf)OK?
W1 bedroom36 x 60 in5+31.9 / -41.7+50 / -50Yes
W2 living72 x 60 in4+30.0 / -32.6+40 / -40Yes
SGD1 slider144 x 96 in4+28.5 / -31.0+35 / -35Yes

The values in this sample schedule are illustrative only.

Can my window's DP be too low for my location?

Yes, and it is one of the most common errors in replacement work. The product's rating must meet or exceed the required pressure, positive and negative, for every opening. If one number falls short, the installation does not comply, even if the product is impact rated.

How it happens:

  • A salesperson quotes one series for the whole house without checking corner zones.
  • A waterfront home is priced as Exposure B.
  • A larger size is ordered than the size the rating applies to.
  • A Panhandle job uses pressures from before ASCE 7-22.
  • Mullions (the bars joining two units) are not checked. FBC 1709.8 requires mullions to carry the design pressure, limits deflection, and requires tested mullions to resist 1.5 times the design pressure.
  • Anchors are installed at wider spacing than the approval allows, which lowers the real capacity no matter what the label says.

What to do

  1. Ask for the wind load chart before you sign.
  2. Check each product's rating on its approval at the exact size ordered.
  3. Ask what exposure category was used and why.
  4. If you are on water or open land, ask whether Exposure D or C was considered.
  5. Confirm the anchor schedule matches your wall type.

Test pressure vs. design pressure (the 1.5x rule)

Products are proven at loads above their rating to build in a safety margin. In the Florida Building Code:

  • Impact-resistant coverings (shutters) "shall be tested at 1.5 times the design pressure (positive or negative)," under FBC 1609.1.2.4.1.
  • Window and door assemblies tested under FBC 1709.5.2 are tested "for 10 seconds at a load equal to 1.5 times the design pressure."
  • Tested mullions must resist "a load of 1.5 times the design pressure," under FBC 1709.8.3.

So a shutter rated at 60 psf was tested at 90 psf. That margin covers variation in materials and installation, not a license to install it where 80 psf is required. Always compare the rated design pressure, not the test pressure, to your requirement.

Cyclic pressure is a different test

Impact products also go through thousands of push and pull cycles after being hit by a missile. In the HVHZ, Table 1626 specifies 9,000 cycles (4,500 inward and 4,500 outward). That test checks whether a damaged unit stays in place through a storm. It is covered in our missile test guide.

Design pressure for shutters, skylights and doors

Shutters. A shutter has its own design pressure and must meet the opening's required pressure, just like a window. It also has to stay clear of the glass when it flexes. In the HVHZ, FBC 1626.2.6.1 requires shutters to resist large missile impacts without deforming enough to touch the window or glass they protect. Shutter approvals typically list minimum separation distances. See types of hurricane shutters.

Skylights. Skylights sit in roof zones, not wall zones, and roof suction near edges and corners is often higher than wall suction. Miami-Dade requires the mean roof height and product approval number of each skylight or glass block system on the plans. See skylights and other openings.

Entry and sliding doors. Exterior side-hinged doors must be tested and labeled under AAMA/WDMA/CSA 101/I.S.2/A440 or comply with FBC 1709.5.2. Large sliders often carry lower ratings at their biggest sizes, so check the exact width and height. See impact sliding glass doors.

Garage doors. These use FBC Residential Table R301.2(4) or ASCE 7, as covered above. In Texas, TDI says garage doors must be tested to ASTM E330 and glass panels rated to ASTM E1996.

How to choose a provider

  • Find your design wind speed with the ASCE 7 Hazard Tool or your building department.
  • Ask which exposure category (B, C or D) applies to each side of your home and why.
  • Measure or confirm your mean roof height.
  • Mark which openings fall within 4 feet of an outside corner (Zone 5).
  • Get a wind load chart listing each opening's required positive and negative pressure.
  • Check each product's approval at the exact size ordered, positive and negative.
  • Confirm mullions and anchors are rated for the same pressures.
  • For homes over 60 feet or threshold buildings, expect an engineer's ASCE 7 calculation.
  • Keep the chart and approvals with your permit for resale and insurance.
  • Leave temporary DP labels on until the final inspection, and photograph them.

Related hurricane shutters and impact windows guides

Hurricane shutters and impact windows by state and city

Questions people ask

What DP rating do I need for my house in Florida?

It depends on your wind speed, the zone of each opening (corner or field of wall), the opening size, your mean roof height and your exposure category. Using the FBC Residential tables, a corner window on a one-story inland home at 160 mph may need about -28 psf, while the same window on open water may need about -51 psf. There is no single statewide number. Ask your contractor for a wind load chart that lists each opening.

Is DP50 good enough for a hurricane?

DP50 is a common rating that meets many inland Florida and Texas openings, but not all. Corner windows on waterfront homes, two-story homes at high wind speeds, and HVHZ homes often need more. A DP rating is also not an impact rating. In a windborne debris region the product must pass impact tests too. Check DP50 against the required pressure for each specific opening, positive and negative.

What is the difference between design pressure and structural test pressure?

Design pressure is the rated value the product is approved to carry in service. The structural test applies a higher load to prove a safety margin. The Florida Building Code tests shutters at 1.5 times the design pressure and window and door assemblies under Section 1709.5.2 for 10 seconds at 1.5 times the design pressure. Compare the design pressure, not the test pressure, to what your opening requires.

Why did my contractor quote different windows for the corners?

Because corner zones (Zone 5) have higher negative pressures than the main wall (Zone 4). In the FBC Residential table at 160 mph, a 10 square foot window is -30.0 psf in Zone 4 and -37.0 psf in Zone 5 before height and exposure adjustment. Using a higher-rated product only at the corners can be correct and cost-effective, as long as each unit meets its own opening's requirement.

Can I use the ATC Hazards by Location website to find my wind speed?

Not for current Florida permits. The Florida Building Commission's fact sheet says the ATC site supports ASCE 7-16, 7-10 and 7-05 only, will not be updated for ASCE 7-22, and cannot be used for site-specific wind speeds under the 8th Edition FBC as of December 31, 2023. Use the ASCE 7 Hazard Tool or ask your local building department, which may have its own adopted speeds.

Does living on a lake change my required window rating?

It can. Exposure D applies where open water extends at least 5,000 feet upwind (or 20 times the building height) and to sites within 600 feet of that condition. Even a smaller open area can push a home into Exposure C if it is within 100 feet of open terrain extending more than 600 feet upwind. Higher exposure means higher pressure. Ask your contractor which exposure was used for each side of the house.

Does a taller house need stronger windows?

Generally yes. The FBC Residential height and exposure multipliers rise with mean roof height. In Exposure C, the multiplier is 1.21 at 15 feet and 1.40 at 30 feet, so a two-story home needs roughly 16 percent higher ratings than a one-story home in the same spot. Homes over 60 feet mean roof height fall outside the simplified tables and need an engineer's ASCE 7 calculation.

Does Texas use the same DP rules as Florida?

The physics and the underlying ASCE 7 method are the same, but the codes differ. Texas coastal windstorm certification now uses the 2024 IRC or IBC, with wind speed determined per structure, according to TDI. Inland Texas cities enforce their own adopted codes. Florida uses the Florida Building Code with Florida amendments, including the HVHZ rules. Product labels show the DP either way.

Do I need a new DP calculation if I replace only one window?

In Florida, yes, in effect. A replacement window must meet current FBC Residential design pressures for its opening, and FBC 107.1.1 makes that a condition of skipping sealed drawings for same-size replacements. The calculation can be quick from the residential tables. Keep a copy with your permit. It also helps at resale and on a wind mitigation inspection.

What does the negative sign mean on my window label?

The negative number is the suction rating: how hard wind can pull the unit outward from the wall. Positive is wind pushing in. Both are in pounds per square foot. Suction is usually the larger demand at corners and is what pulls windows and shutters off homes, so it is often the number that decides whether a product fits an opening.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration