Local Guide · Hurricane shutters and impact windows
Florida Building Code Opening Protection Rules: When Is Impact Protection Required?
Where Florida's windborne debris region applies, what R301.2.1.2 and FBC 1609.1.2 require, the exceptions, the Panhandle history, code editions through 2026, and how Texas compares.
Under the Florida Building Code, glazed openings in new construction (and, with some exceptions, replacement windows and doors) in a windborne debris region must be impact resistant or protected by approved shutters or panels. The region covers areas within 1 mile of the coast where the design wind speed is 130 mph or more, and anywhere it is 140 mph or more. All of Miami-Dade and Broward (the HVHZ) must protect every envelope opening. Look up your address with the ASCE 7 Hazard Tool and confirm with your building department.
Key facts
- FBC wind-borne debris region: within 1 mile of the coastal mean high water line where Vult is 130 mph or more, or anywhere Vult is 140 mph or more.
- Hurricane-prone regions are Atlantic and Gulf coast areas where Risk Category II Vult exceeds 115 mph.
- FBC Residential R301.2.1.2 accepts ASTM E1996/E1886 large missile, TAS 201/202/203 or AAMA 506; 7/16 in wood panels are allowed up to 33 ft mean roof height and 180 mph.
- FBC 1609.1.2: glazing within 30 ft of grade must pass the large missile test; above 30 ft, the small missile test.
- Sheds of 720 sq ft or less not for habitation are exempt from the debris rules (FBC 1609.1.2).
- In the HVHZ, every envelope component must meet impact criteria or be protected (FBC 1626.1).
- The Panhandle 1-mile exemption was removed from law in 2006 (SB 1774), with a new 130 mph contour region effective no later than May 31, 2007 (Florida Building Commission minutes).
- 8th Edition (2023) FBC effective December 31, 2023; 9th Edition (2026) effective December 31, 2026 (DBPR).
- TDI: most Texas designated catastrophe areas are inside the windborne debris region under the 2024 IRC/IBC, required since April 1, 2026.
Does Florida law require hurricane shutters or impact windows?
Florida does not have a law that orders every existing home to add shutters. What it has is a building code that requires opening protection when you build, and sets rules when you replace windows and doors. The Florida Building Code (FBC) requires exterior glazed openings in a windborne debris region to be impact resistant or covered by an approved impact-resistant covering. Outside that region, impact protection is not required by the code, though design pressure rules still apply everywhere.
Three other rule sets can also require protection:
- Replacement rules in the FBC Existing Building volume (Section 707.4), which can require new windows and doors to meet current impact rules. See our replacement guide.
- Condo and HOA rules. A condo association may require owners to install hurricane protection with a majority vote of voting interests under s. 718.113(5), and HOAs must adopt hurricane protection specifications under s. 720.3035(6). See our condo and HOA guides.
- Insurance and grant conditions. Insurers rate opening protection on the wind mitigation form, and My Safe Florida Home may require improvements to all openings as a grant condition.
This page explains the code side: what a windborne debris region is, where it applies, what counts as protection, the exceptions, and how the code has changed.
What is a windborne debris region?
The FBC uses two map-based terms. Both come from the code's definitions chapter.
- Hurricane-prone regions: the U.S. Atlantic Ocean and Gulf of Mexico coasts where the ultimate design wind speed (Vult) for Risk Category II buildings is greater than 115 mph, plus Hawaii, Puerto Rico, Guam, the Virgin Islands and American Samoa.
- Wind-borne debris region: the part of a hurricane-prone region that is (1) within 1 mile of the coastal mean high water line where Vult is 130 mph or greater, or (2) anywhere Vult is 140 mph or greater.
| Your site's design wind speed (Vult) | Within 1 mile of the coast | More than 1 mile from the coast |
|---|---|---|
| Less than 130 mph | Not a windborne debris region | Not a windborne debris region |
| 130 to 139 mph | Windborne debris region | Not a windborne debris region |
| 140 mph or more | Windborne debris region | Windborne debris region |
Which map? For Risk Category II and III buildings (other than health care facilities), the region is based on Figure 1609.3(1). Risk Category III health care facilities use Figure 1609.3(2), and Risk Category IV buildings, such as hospitals with emergency treatment, fire and police stations and designated shelters, use Figure 1609.3(3). A hospital can therefore be in the region where a house next door is not.
The same three tiers appear on the 2026 wind mitigation form
Florida's revised Uniform Mitigation Verification Inspection Form (OIR-B1-1802, Rev. 04/26) asks inspectors to place each home in a "Region" based on the ASCE 7-22 Risk Category 2 design wind speed: HVHZ, Region 1 (140 mph or more), Region 2 (130 to 139 mph) or Region 3 (less than 130 mph). Those tiers line up with the code's debris region thresholds.
What about lakes? A 2022 national change Florida did not keep
The national standard ASCE 7-22 changed the definition for 130 to 139 mph areas. A University of Florida report prepared for the Florida Building Commission (draft final, May 15, 2024) explains that ASCE 7-22 "removed specific reference to the coast and designated the WBDR to be within one mile of any body of water where an Exposure D condition exists," which can include large inland lakes. The report says this definition "was initially adopted in the 8th Ed. Florida Building Code" but that "the current version of the 8th Ed. FBC has reverted" to the coastal-only definition. So, as of the current 8th Edition, lakes do not trigger the one-mile rule in Florida. The report studied whether Florida should adopt the lake rule. Check with your building department whether the 9th Edition (2026) changes this for your permit.
What does FBC R301.2.1.2 say?
Section R301.2.1.2 of the FBC Residential is the main rule for one- and two-family homes and townhouses. In plain English:
- Exterior glazed openings (windows, glass doors, skylights, glass in garage doors) in windborne debris regions must be protected.
- Protection must meet the Large Missile Test of ASTM E1996 and ASTM E1886 (as modified by the code), TAS 201, 202 and 203, or AAMA 506.
- Wood structural panels at least 7/16 inch thick, with a maximum 44-inch span between fastener lines, may be used instead on homes with a mean roof height of 33 feet or less where Vult is 180 mph or less, as long as the attachment hardware and anchors are permanently installed and corrosion resistant.
- Section R301.2.1.2.1 rewrites the ASTM E1996 wind zones to match Florida's ultimate wind speeds.
The FBC Building, Section 1609.1.2, has the parallel rule for all other buildings. It adds ANSI/DASMA 115 for garage and rolling doors and a 30-foot height split: glazing within 30 feet of grade must pass the large missile test, and glazing above 30 feet the small missile test. See our missile test guide.
Is plywood allowed?
Yes, within limits. The panels must be precut to overlap the wall at least 2 inches beyond the fastener lines, predrilled, and secured with corrosion-resistant hardware permanently installed on the building. For wood-frame walls, anchors are sized on 1/4-inch lag screws with at least 300 pounds of allowable withdrawal capacity. For concrete or masonry walls, anchors need at least 300 pounds of withdrawal capacity and 525 pounds of shear capacity, with a 1-1/2 inch edge distance. Plywood is not allowed above 180 mph or on homes above 33 feet mean roof height under this exception. See our plywood guide.
Are garage doors included in opening protection?
Yes, in two ways. First, glass in a garage door is a glazed opening. FBC 1609.1.2.3 requires garage door glazed opening protection for windborne debris to meet "an approved impact-resisting standard or ANSI/DASMA 115." Second, every garage door must resist wind pressure. The FBC Residential gives garage door wind loads in Table R301.2(4), adjusted for height and exposure. A 16-by-7-foot door at 160 mph, 30 feet mean roof height, Exposure B, is rated for +23.3/-26.0 psf before adjustment.
In the High-Velocity Hurricane Zone, FBC 1626.1 goes further: all parts of the building envelope, including exterior doors, must meet impact criteria or be protected. On the wind mitigation form, garage doors are their own column for both glazed and non-glazed doors, and a non-glazed garage door with only a wind pressure rating counts as Level D, which can lower your opening protection sub-rating.
Garage doors matter more than many owners think. IBHS says a garage door pushed in by high winds lets pressure build inside the home, pushing up on the roof and out on the walls, and it calls a wind-rated garage door one of the two most significant ways to improve a home's hurricane resilience. See our garage door guide.
Are there exceptions for high windows, porches and other buildings?
Yes. The FBC lists several, mostly in Section 1609.1.2 and the HVHZ section 1626.1.
| Exception | What it says | Code section |
|---|---|---|
| High glazing | Glazing in Risk Category II, III or IV buildings more than 60 feet above ground and more than 30 feet above any aggregate-surfaced roof within 1,500 feet may be unprotected | FBC 1609.1.2 |
| Glazing above 30 feet | Small missile test instead of large missile (except HVHZ Risk Category IV) | FBC 1609.1.2; 1626.3 |
| Sheds | Storage sheds not designed for human habitation with 720 sq ft or less of floor area are exempt | FBC 1609.1.2 |
| Sunrooms, balconies and enclosed porches | Openings may go unprotected if the space is under an existing roof or deck and a wall with all-protected openings separates it from the interior | FBC 1609.1.2; FBC-EB 707.5 |
| Louvers within 30 ft of grade | Must meet AMCA 540 or be covered by a large-missile-rated cover | FBC 1609.1.2.1 |
| HVHZ exemptions | Include screen-room roofs that do not breach the envelope, soffit and ridge vents, vents in garages for four or fewer cars, HVAC wall and roof openings, roof hatches, and buildings for marinas, cabanas, pools and greenhouses | FBC 1626.1 |
| Plywood | 7/16 in wood structural panels allowed on R-3/R-4 buildings up to 33 ft mean roof height where Vult is 180 mph or less | FBC 1609.1.2; R301.2.1.2 |
Exceptions are narrow. A screened lanai does not exempt the sliding doors behind it unless the wall between the lanai and the house is fully protected. Ask your building department before relying on any exception.
Which areas of Florida require opening protection on new homes?
The rule is the same statewide; the result depends on your wind speed and distance to the coast. Wind speeds come from the code's maps and can be found for any address with the ASCE 7 Hazard Tool (the Florida Building Commission says the older ATC Hazards by Location site cannot be used under the 8th Edition). Local governments sometimes adopt their own speeds, so the Commission advises contacting your local building department for a specific site.
County and city guide
| Area | Risk Category II wind speed we could verify | How the debris rule applies |
|---|---|---|
| Miami-Dade County (Miami, Homestead, Miami Beach) | 175 mph (FBC 1620.2) | HVHZ: the entire envelope (glazing, doors, skylights, glass block) must meet impact criteria or be protected, countywide (FBC 1626.1) |
| Broward County (Fort Lauderdale, Hollywood) | 170 mph (FBC 1620.2) | HVHZ: same countywide rule |
| City of Sebastian (Indian River County) | 160 mph, by city ordinance | 140 mph or more, so the whole city is in the region |
| Bay County (Panama City, Panama City Beach) | The county's 2023 FBC map shows 130 mph and 140 mph contours and a 1-mile coastal debris strip | Mixed: coastal strip and areas at or above 140 mph are in; areas between 130 and 140 mph more than 1 mile from the coast are not |
| Tampa, St. Petersburg, Clearwater | Look up by address | Within 1 mile of the Gulf or Tampa Bay shoreline: in the region if Vult is 130 or more. Farther inland: in the region only where Vult is 140 or more |
| Jacksonville | Look up by address | Same two tests. Note the coastal test runs from the coastal mean high water line |
| Orlando and other inland Central Florida | Look up by address | No coastline within 1 mile, so protection is required only where Vult is 140 mph or more. Under the current 8th Edition, lakes do not trigger the 1-mile rule |
| Western Panhandle (Pensacola to Destin) | Increased under ASCE 7-22 for Risk Categories I to III | Re-check older projects: the higher speeds can expand the area at or above 140 mph |
We list wind speeds only where we could confirm them in an official source. For every other address, use the ASCE 7 Hazard Tool with Risk Category II (for a home) and confirm with your building department.
Do I need impact windows in Orlando?
Only if your address is at or above 140 mph on the Risk Category II map, or your local department says so. Many Orlando-area homes are built without impact protection under the code. Even where protection is not required, windows and doors must still meet design pressures, and insurers may give credit for protection you add.
Tampa, St. Petersburg and Jacksonville
Waterfront and near-water neighborhoods are the most likely to fall in the region. The one-mile strip is measured from the coastal mean high water line. If you are close to the line, ask the building department how it measures it for your parcel.
Do Panhandle homes need impact protection? The history of the one-mile rule
For years, the Florida Panhandle had a special exception. Florida Building Commission minutes from its June 19, 2006 meeting in Destin describe the Panhandle wind-borne debris region as running "from the eastern border of Franklin County to the Alabama border," with the code designation at that time limited to "1 mile from the coast." That meant many Panhandle homes in high-wind areas did not need opening protection if they were more than a mile inland.
The minutes record that in February 2006 the Commission asked the Legislature to remove the statutory definition, and that "SB 1774 passed and the panhandle wind borne debris region exemption was removed from law." On June 19, 2006, the Commission voted 12 to 3 to set the Panhandle region at the 130 mph contour (its "Option C"), stating the new definition "will become effective no later than May 31, 2007."
So the special Panhandle carve-out ended in 2006 and 2007, more than a decade before Hurricane Michael. Today the Panhandle uses the same statewide definition as the rest of Florida: within 1 mile of the coast at 130 mph or more, or anywhere at 140 mph or more. What changed after the 2023 code update is the wind map itself: ASCE 7-22 raised design wind speeds in the western Panhandle for most building types, according to the Commission's fact sheet.
Michael showed why this matters. NWS Tallahassee reports Michael made landfall on October 10, 2018 as a Category 5 with 161 mph (140 knot) sustained winds. The University of Florida debris region report notes debris damage after Michael more than three miles from an inland bay. If your Panhandle home was built before 2007, it may have been permitted under the old one-mile limit and lack protection that a new home would need today.
Which Florida Building Code edition is current, and what came before?
| Code | Key date | What it means for openings |
|---|---|---|
| South Florida Building Code 1994 (HVHZ) | Permits after 9/1/1994 (per the mitigation form) | Post-Andrew code in Miami-Dade and Broward. Hurricane Andrew (August 24, 1992) damaged or destroyed over 125,000 homes in Dade County, and NCEI notes codes were enhanced afterward |
| FBC 2001 / 2004 | Permits after 3/1/2002 for homes built in 2002 to 2003 | First statewide Florida Building Code |
| FBC 2007 and later | Permits after 12/8/2006 for homes built in 2007 to 2008 | The mitigation form's second code tier; the Panhandle exemption had been removed |
| 8th Edition (2023) | Effective December 31, 2023 | References ASCE 7-22; current code |
| 9th Edition (2026) | Effective December 31, 2026, per DBPR | Draft volumes posted; product approvals being updated |
The date cutoffs in rows two to four come from Florida's 2026 mitigation form, which asks inspectors which code was in force at the original permit application.
Does the 2026 (9th Edition) FBC change opening protection?
DBPR confirms the 9th Edition takes effect December 31, 2026, and the draft is available through the Commission's website. We did not find a final, published change to the windborne debris definition or the opening protection sections in the sources we checked. The Commission did study the ASCE 7-22 lake-based definition for the 2026 cycle. Building permits applied for after the effective date will be reviewed under the new edition, and Miami-Dade has said expired applications that do not qualify for extension must be resubmitted under the 2026 code. If your project straddles the date, ask your building department which edition applies and confirm your products are approved under it. See our product approval guide.
Permits and code editions
Under s. 553.79, a single-family building permit expires 1 year after issuance or on the effective date of the next FBC edition, whichever is later, unless the local government extends it. Plan your project timeline around the December 31, 2026 change.
The High-Velocity Hurricane Zone (Miami-Dade and Broward)
Miami-Dade and Broward follow extra FBC sections (1612 to 1626) that are stricter than the rest of the state:
- All envelope components, including exterior walls, roof, outside doors, skylights, glazing and glass block, must meet impact test criteria or be protected (FBC 1626.1).
- Large and small missile tests follow TAS 201 and 203, with the 9-pound 2x4 at 50 feet per second, or 80 feet per second for Risk Category IV (FBC 1626.2).
- All buildings are treated as Exposure C unless Exposure D applies (FBC 1620.3).
- Risk Category II design wind speeds are 175 mph in Miami-Dade and 170 mph in Broward (FBC 1620.2).
See our HVHZ guide.
Texas contrast: windborne debris rules on the Texas coast
Texas has no statewide building code for all homes. On the coast, the rules come through windstorm insurance eligibility. In the designated catastrophe areas (14 first-tier coastal counties plus five Harris County cities east of State Highway 146), construction must be certified by the Texas Department of Insurance to qualify for TWIA coverage. Since April 1, 2026, certification uses the 2024 International Residential Code or 2024 International Building Code.
TDI's 2026 code page says "most of the Designated Catastrophe Areas are now located within the windborne debris region," with protection requirements "as specified in the 2024 IRC and the 2024 IBC," and that wind speed must be set for each structure, using tools such as the ASCE 7 Hazard Tool. An older TDI repair page ties shutter needs to areas at 140 mph and higher; the 2026 page is newer, so follow it and confirm with your inspector.
| Question | Florida | Texas coast |
|---|---|---|
| What code? | Florida Building Code 8th Ed. (2023); 9th Ed. from 12/31/2026 | 2024 IRC/IBC for TDI windstorm certification since 4/1/2026 |
| Who enforces? | Local building departments | TDI-appointed inspectors or Texas-licensed engineers, plus any city code |
| Debris region | 1 mile from coast at 130+ mph, or anywhere at 140+ mph | Per 2024 IRC/IBC; most catastrophe areas are inside it |
| Proof of compliance | Permit, inspections, product approval | WPI-8 Certificate of Compliance |
Houston, Dallas, San Antonio and Austin are outside TDI's catastrophe areas (in Harris County, only La Porte, Morgan's Point, Pasadena, Seabrook and Shoreacres east of SH 146 are in the program). City codes govern there. See our Texas coastal codes guide and the Texas hub.
How to choose a provider
- Look up your Risk Category II wind speed with the ASCE 7 Hazard Tool.
- Measure your distance to the coastal mean high water line if you are near 1 mile.
- Ask your building department whether local wind speeds or amendments apply.
- List every glazed opening, including garage door glass and skylights.
- Check whether any exception (porch wall, sheds, high glazing) truly applies.
- Confirm products are approved for impact resistance and, in Miami-Dade or Broward, the HVHZ.
- If your permit will be filed after December 31, 2026, confirm 9th Edition compliance.
- Keep permit and approval records to document protection for insurance.
Related hurricane shutters and impact windows guides
- Replacing Windows in an Existing Florida Home: Does the New Window Have to Be Impact Rated?
- Design Pressure (DP) Ratings Explained: What Do DP50 and +60/-70 psf Mean for Your Windows?
- Missile Impact Tests Explained: What Are the Large and Small Missile Tests, ASTM E1996/E1886 and TAS 201/202/203?
- What Is the HVHZ? Hurricane Protection Rules in Miami-Dade and Broward vs. the Rest of Florida
- Do You Need a Permit for Impact Windows, Doors and Shutters in Florida? Process, Documents, Fees and Inspections
- Hurricane Protection Rules by Florida County: Miami-Dade, Broward, Palm Beach, the Keys, Southwest Florida, Tampa Bay, Orlando, Jacksonville and the Panhandle
- What Building Codes Apply to Windows and Shutters on the Texas Coast?
- Impact Windows vs. Hurricane Shutters: Which Protection Is Right for Your Home or Business?
Hurricane shutters and impact windows by state and city
Questions people ask
Is impact protection required within 1 mile of the coast?
Yes, if your site's ultimate design wind speed is 130 mph or more. The Florida Building Code defines the windborne debris region as the part of a hurricane-prone region within 1 mile of the coastal mean high water line where Vult is at least 130 mph, plus anywhere Vult is at least 140 mph. Glazed openings in that region must be impact resistant or protected with approved coverings.
Is impact protection required where wind speed is 140 mph or more?
Yes. Anywhere in a hurricane-prone region with a Risk Category II ultimate design wind speed of 140 mph or more is a windborne debris region under the FBC, regardless of distance to the coast. That includes all of Miami-Dade (175 mph) and Broward (170 mph) and places such as the City of Sebastian (160 mph by ordinance). Use the ASCE 7 Hazard Tool for other addresses.
Do I need impact windows on an existing home if I am not remodeling?
The building code does not force existing homes to retrofit just because the code changed. Section 553.8425(7) says code changes do not void approvals of products installed when they met the code. Protection can still be required when you replace windows or doors, by a condo association vote under s. 718.113(5), or as a condition of some grants. Insurers also give discounts for verified protection.
Do lakefront homes in Central Florida need impact windows?
Under the current 8th Edition FBC, the 1-mile trigger is measured from the coast, not from lakes. A University of Florida report for the Building Commission says ASCE 7-22 would have extended it to large lakes with open-water exposure, but the current 8th Edition reverted to the coastal definition. Lakefront homes still face higher design pressures from Exposure C or D. Check whether the 9th Edition changes this.
Are shutters or impact windows better for meeting the code?
The code treats them as equal if both are approved and installed correctly. R301.2.1.2 accepts impact-resistant glazing or impact-resistant coverings tested to ASTM E1996/E1886, TAS 201/202/203 or AAMA 506. TDI in Texas says installing both is not necessary. The choice comes down to cost, convenience, appearance and whether someone will be home to close shutters. See our comparison guide.
Does the code require protecting skylights?
Yes, where glazing protection applies. Skylights are glazed openings. In the HVHZ, FBC 1626.1 lists skylights among envelope parts that must meet impact criteria or be protected. Statewide, Florida's mitigation form rates skylights separately and gives top credit to skylights tested with a 4.5-pound missile under ASTM E1886 and E1996. Skylights also sit in high-suction roof zones.
When did the Panhandle exemption end?
Florida Building Commission minutes from June 19, 2006 say SB 1774 removed the Panhandle windborne debris exemption from law, and the Commission adopted a new Panhandle region at the 130 mph contour, effective no later than May 31, 2007. Before that, the Panhandle region from Franklin County west was limited to 1 mile from the coast. Today the Panhandle uses the statewide definition.
Does a screened porch count as an opening I must protect?
Not usually. Under FBC 1609.1.2 and FBC Existing Building 707.5, openings in sunrooms, balconies and enclosed porches under existing roofs or decks may go unprotected if a wall with fully protected openings separates the space from the house. The doors and windows in that separating wall must be protected. In the HVHZ, check Chapter 16 requirements with the building department.
Sources
- Florida Building Code, Building 8th Ed. (2023), Chapter 2 Definitions (via UpCodes)
- Florida Building Code, Building 8th Ed. (2023), Chapter 16 (via UpCodes)
- Florida Building Code, Residential 8th Ed. (2023), Chapter 3 (via UpCodes)
- Florida Building Code, Existing Building 8th Ed. (2023), Chapter 7 (via UpCodes)
- Florida Building Commission, Wind Loads: Impacts from ASCE 7-22 fact sheet (June 2024)
- UF and Florida Building Commission, Investigation of the Wind-borne Debris Regions in ASCE 7-22 (Draft Final Report, May 15, 2024)
- Florida Building Commission, Minutes of June 19, 2006 plenary session
- DBPR, 2026 FBC Update: State Product Approval and the FBC 9th Edition (June 30, 2026)
- Florida Building Commission home page
- Florida OIR, Form OIR-B1-1802 Rev. 04/26
- City of Sebastian, Ultimate Wind Speeds
- Bay County, Wind-Borne Debris Map, 2023 FBC 8th Edition
- Miami-Dade County, Building home page (2026 FBC notices)
- Fla. Stat. 553.79, Permits; applications; issuance; inspections (2026)
- Fla. Stat. 553.8425, Local product approval (2026)
- Fla. Stat. 718.113 (2026)
- Fla. Stat. 720.3035 (2026)
- NOAA NCEI, Billion-Dollar Disasters, Florida summary
- NWS Tallahassee, Hurricane Michael 2018
- IBHS FORTIFIED, Before the Storm: A Homeowner's Guide to Hurricane Readiness
- Texas Department of Insurance, Adopted Building Codes (windstorm)
- Texas Department of Insurance, Making repairs after a storm
- Texas Department of Insurance, Windstorm general questions
This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.