Local Guide · Hurricane shutters and impact windows
Can You Use Plywood for Hurricane Shutters? Code Rules, Thickness, Fasteners and Where Plywood Is Not Allowed
Plywood or OSB can count as hurricane protection in much of Florida and coastal Texas, but only if it meets the building code's wood structural panel exception: at least 7/16 inch thick, precut, predrilled and fastened to anchors permanently installed on the house. It is not an option in Miami-Dade and Broward. Here is exactly what the codes say.
Yes, in most of Florida outside Miami-Dade and Broward, plywood or OSB can be legal opening protection if it meets the Florida Building Code exception: panels at least 7/16 inch thick, a span of no more than 44 inches between lines of fasteners, on homes with a mean roof height of 33 feet or less where design wind speed is 180 mph or less, precut and fastened to permanently installed corrosion-resistant anchors. Texas follows the IRC's similar wood structural panel exception.
Key facts
- Florida Building Code 1609.1.2 and Florida Residential Code R301.2.1.2 (2023) allow wood structural panels at least 7/16 inch thick with a span between lines of fasteners of 44 inches for opening protection on homes with a mean roof height of 33 feet or less where Vult is 180 mph or less.
- Panels must be precut to extend at least 2 inches beyond the lines of fasteners, predrilled, and secured with corrosion-resistant attachment hardware permanently installed on the building.
- As a prescriptive alternative to designed attachments, the Florida codes allow panels fastened at 16 inches on center along the edges of the opposing long sides.
- For concrete or masonry walls, Florida requires fasteners at least 1.5 inches from the edge of the opening and 2 inches in from the panel edge, with permanent anchors rated for at least 300 lb ASD withdrawal and 525 lb ASD shear.
- For wood frame walls, Florida requires fasteners at least 1 inch from the opening edge and 2 inches in from the panel edge, with anchors based on 1/4-inch lag screws giving at least 300 lb ASD withdrawal.
- Hex nuts, washered wing nuts or bolts must be at least 1/4-inch hardware with washers of at least 1-inch outside diameter.
- FBC 1601.1 sends buildings in the High-Velocity Hurricane Zone (Miami-Dade and Broward) to Sections 1616 to 1626, where 1626.1 requires openings to meet impact test criteria or be protected by a device that does.
- On Florida's wind mitigation form (OIR-B1-1802), plywood or OSB meeting Table 1609.1.2 of the 2007 FBC rates as level C, below tested shutters at levels A and B.
- The Texas Department of Insurance says plywood or OSB shutters may be possible, depending on secure attachment, safe handling and permanent fasteners in the wall framing, and points owners to 2024 IRC R301.2.1.2.
Is plywood allowed as hurricane protection in Florida?
Yes, outside the High-Velocity Hurricane Zone, but only if it meets the building code's wood structural panel exception. "Wood structural panel" means plywood or oriented strand board (OSB). The exception appears in two places in the Florida Building Code, 8th Edition (2023):
- FBC Building 1609.1.2, Exceptions: for Group R-3 or R-4 occupancy buildings (which include one- and two-family homes) with a mean roof height of 33 feet or less where the ultimate design wind speed (Vult) is 180 mph or less.
- FBC Residential R301.2.1.2, Exception: for buildings with a mean roof height of 33 feet or less where Vult is 180 mph or less.
Both say the same core things: the panels must be at least 7/16 inch thick, the span between lines of fasteners is 44 inches, and the panels must be precut, predrilled and fastened to corrosion-resistant hardware permanently installed on the building.
If you live in the wind-borne debris region and use plywood that does not meet these rules, it may still help in an emergency, but it is not code-compliant opening protection and will not earn the same insurance credit. For the bigger picture of what the code requires, see Florida Building Code opening protection.
A note on code cycles: the Florida Building Commission lists the 8th Edition (2023) as effective December 31, 2023, and the 9th Edition (2026) Florida Building Code takes effect December 31, 2026, according to DBPR. Check with your building department for the edition in force when you do the work.
The Florida code requirements, line by line
| Requirement | Florida Building Code (2023) exception | What it means for you |
|---|---|---|
| Material | Wood structural panels | Plywood or OSB rated as structural panels. |
| Thickness | Not less than 7/16 inch | 7/16 inch is the minimum. Thicker is allowed but heavier. |
| Span | 44 inches between lines of fasteners | Fastener rows on opposite sides of the panel can be no more than 44 inches apart. That limits the width (or height) of opening a panel can cover. |
| Building height | Mean roof height of 33 feet or less | Most one-story and many two-story homes. Measure from grade to the middle of the roof slope if unsure, or ask the building department. |
| Wind speed | Vult 180 mph or less | Your building department can give the design wind speed for your address. |
| Overlap | Precut to extend at least 2 inches beyond the lines of fasteners | Cut panels in advance so they lap onto the wall around the opening. |
| Attachment | Attached to the framing surrounding the opening; predrilled; corrosion-resistant attachment hardware permanently installed | Anchors stay in the wall year-round. You bolt the panels to them before a storm. |
| Design | Attachments designed for component and cladding loads (Table R301.2(2) or ASCE 7), or, as an alternative, fastened at 16 inches on center along the edges of the opposing long sides | The 16-inch spacing is the simple, prescriptive route. |
| Fastener table | Table 1609.1.2 and Table R301.2.1.2 are marked "Reserved" | The 2023 Florida codes no longer print a fastener-by-span table. The rules are written into the exception text instead. |
Fastener placement and anchor strength (Florida)
| Wood frame wall | Concrete or masonry wall | |
|---|---|---|
| Distance from edge of opening | Nominally at least 1 inch, embedded into the wall framing | At least 1.5 inches |
| Distance in from panel edge | 2 inches | 2 inches |
| Permanent anchor | Threaded portion based on 1/4-inch lag screws, long enough to pass through siding or stucco with embedment for at least 300 lb ASD withdrawal | At least 300 lb ASD withdrawal and 525 lb ASD shear capacity at a 1.5-inch edge distance |
| Nuts and bolts | At least 1/4-inch hex nuts, washered wing nuts or bolts, with washers at least 1 inch in outside diameter | Same: at least 1/4-inch hardware with 1-inch washers |
The code also allows vibration-resistant alternative attachments designed for the required loads. ASD means allowable stress design, an engineering way of rating a fastener's safe working load. When you buy anchors, look on the package or the manufacturer's data sheet for allowable withdrawal and shear values in the type of wall you have.
What does the 44-inch span mean in real life?
It is the distance between the two rows of fasteners on opposite sides of the panel. Because fasteners must sit 2 inches in from the panel edge, a standard 48-inch-wide sheet with fastener rows along both long edges has rows 44 inches apart. Because fasteners must also sit at least 1 inch (wood frame) or 1.5 inches (masonry) outside the edge of the opening, the opening itself must be a bit narrower than 44 inches in that direction.
Example: A bedroom window in a block home is 36 inches wide and 60 inches tall. You cut a 7/16-inch sheet to cover it with a 2-inch-plus overlap, set fastener rows along the two long sides about 40 to 44 inches apart, and place fasteners at 16 inches on center down each side. That fits the prescriptive alternative as we read it.
Counter-example: A 72-inch-wide picture window or a 6-foot sliding door is wider than the span limit in both directions once you account for height. It is outside the prescriptive exception. You would need a different product, such as an approved panel, accordion or roll-down shutter, or an engineered design. Ask your building department before relying on plywood for any opening wider than about 40 inches.
This is our plain reading of the code text. Your local building official makes the final call, so confirm before you install anchors.
Is plywood allowed in Miami-Dade and Broward (the HVHZ)?
Not under this exception. Miami-Dade and Broward make up Florida's High-Velocity Hurricane Zone (HVHZ). FBC 1601.1 says buildings in the HVHZ follow Sections 1605, 1607, 1611 and 1616 through 1626 (plus 1612 in flood areas). Section 1609, which holds the plywood exception, is not on that list. In the HVHZ, Section 1626.1 requires every part of the building envelope, including windows, doors and skylights, to meet impact test criteria or be protected by an external protection device that meets them. HVHZ shutters are tested to TAS 201 and TAS 203, including a 9-pound 2 by 4 missile at 50 feet per second, and must not deflect enough to touch the glass.
Field-cut plywood has no such test or approval for your opening. In Miami, Fort Lauderdale and the rest of both counties, use products with a Miami-Dade NOA or Florida product approval valid for the HVHZ. See HVHZ requirements and Miami-Dade NOA lookup. Plywood can still be an emergency stopgap over a broken window after a storm, but it is not code-level protection there.
What thickness of plywood do I need: 7/16 or 5/8?
The Florida codes and the IRC both set 7/16 inch as the minimum. Nothing in the exception requires 5/8 inch. Thicker panels are stiffer and resist debris better in general, but they are heavier to carry and lift, especially up a ladder. If you choose thicker material, you still have to meet the same span, overlap, anchor and fastener rules. Do not go thinner than 7/16 inch: thinner sheets do not meet the exception.
Is OSB acceptable instead of plywood?
Yes, under the code wording. The exceptions say "wood structural panels", and the Texas Department of Insurance describes a wood structural panel shutter as made from either plywood or oriented strand board. Florida's wind mitigation form also groups them together as "plywood or OSB" for level C. OSB can swell if it stays wet, so store it dry and check edges before each season. Look for a structural panel grade stamp on the sheet.
How to attach plywood to a concrete block house
- Plan each opening. Measure the opening. Confirm it fits the 44-inch span limit in one direction.
- Cut the panel so it extends at least 2 inches beyond where your fastener lines will be, which puts the panel edges well past the opening.
- Mark fastener locations 2 inches in from the panel edges along the two opposing long sides, at 16 inches on center (the prescriptive alternative), and at least 1.5 inches outside the edge of the opening.
- Install permanent anchors in the block or concrete at those points. Use corrosion-resistant anchors rated for at least 300 lb ASD withdrawal and 525 lb ASD shear at a 1.5-inch edge distance. Drill into solid material, not mortar joints or hollow cells, as the anchor maker directs.
- Predrill the panel to match the anchors exactly. Hold it up and test-fit.
- Fasten with at least 1/4-inch hex nuts, washered wing nuts or bolts and 1-inch washers.
- Label and store the panel and hardware for that opening together.
Cap or plug the anchors when panels are off, if the anchor maker offers caps, to keep debris out of threads.
How to attach plywood to a wood-frame house
- Find the framing. Fasteners must go into the wall framing around the opening, nominally at least 1 inch from the opening edge.
- Cut and mark as above: 2 inches in from the panel edge, 16 inches on center along the two opposing long sides.
- Install permanent anchors based on 1/4-inch lag screws, long enough to pass through your siding or stucco and embed in framing for at least 300 lb ASD withdrawal.
- Predrill, test-fit, fasten with the 1/4-inch hardware and 1-inch washers.
- Seal around permanent anchors per the anchor and siding maker's instructions to keep water out of the wall.
Do not nail plywood into window trim or frames. Nails pull out and damage the window. The code calls for attachment to the framing around the opening with permanent anchors.
Are plywood window clips code compliant?
Some products clip plywood inside the window frame or opening instead of bolting it to anchors in the wall. The code exception we quote above describes panels that overlap the wall and fasten to permanently installed anchors in the framing or masonry around the opening. A clip that grips the window or opening edge is a different method. We found no provision in the Florida exception that lists clips as an accepted method. If a clip system claims to be approved, look up its product approval or NOA and read the limits for your opening size and wall type. Without a valid approval that matches your opening, assume clips are an emergency measure only and will not count as code-level protection or earn insurance credit.
Does plywood count for insurance discounts?
It can, at a lower level than tested shutters. On Florida's Uniform Mitigation Verification Inspection Form (OIR-B1-1802, Rev. 04/26), opening protection is graded A, B, C, N, X or Z by the weakest glazed opening:
- Level C is plywood or OSB panels that meet Table 1609.1.2 of the 2007 Florida Building Code.
- Level N covers coverings that cannot be identified as A, B or C.
- Level A and B require tested, approved products.
To give the inspector a fair shot at level C, have panels precut and labeled for every opening, anchors installed, and hardware on hand, and show the panels during the inspection. Citizens tells policyholders to make stored shutters or panels available to the inspector. If even one glazed opening has no panel, the house rates by that opening. See wind mitigation form and opening protection and Citizens and opening protection.
Can I use plywood on a two-story house?
The Florida exception is not written in stories; it is written in mean roof height: 33 feet or less. Many two-story homes are under that, but check. The bigger problem is safety. Lifting a 4 by 8 sheet onto upper-story anchors from a ladder is hard and dangerous, and the Texas Department of Insurance lists "the ability to safely carry and install the large panels" as one of the factors in whether wood panel shutters are right for you. If you cannot safely reach upper windows, consider permanent protection for those openings.
Does plywood work on sliding glass doors?
Usually not under the prescriptive exception. A typical sliding door opening is far wider and taller than the 44-inch span allows. You would need an engineered design or an approved product made for that size, such as accordion shutters, roll-downs, or approved panels. See impact sliding glass doors and accordion shutters.
How should I precut, label and store plywood panels?
- Cut and drill everything in the off-season. The code requires precut, predrilled panels, and a rushed cut on a storm day is how mistakes happen.
- Label each panel with the room and wall (for example "Kitchen-N") and an arrow for up and outside. Keep a printed map of the house with the same labels.
- Bag the hardware for each panel and tape the bag to it, or keep a labeled bin.
- Paint or seal panels and edges to slow moisture damage, and store them flat and dry, off the floor. Warped or swollen panels may not line up with anchors.
- Do a test fit every spring. The Texas Department of Insurance advises a practice install on one or two openings to learn the time needed.
For timing and order of installation, see when to put up hurricane shutters.
Texas: are plywood shutters allowed for windstorm certification?
The Texas Department of Insurance (TDI) runs the Windstorm Inspections Program for the 14 first-tier coastal counties and parts of Harris County east of State Highway 146. TDI lists three choices for openings: impact-resistant windows and doors, hurricane shutters customized to fit, and, "as an emergency measure," plywood panels installed properly. On its storm repair page, TDI says wood structural panel shutters made from plywood or OSB "may be possible" depending on the ability to secure them properly, to carry and install them safely, and to install permanent fasteners into the wall framing. TDI points owners to 2024 IRC Section R301.2.1.2 for the rules. TDI says that under the 2024 codes, most designated catastrophe areas are now in the windborne debris region.
What the IRC exception says
The 2024 IRC text of R301.2.1.2, as published for Texas on UpCodes, allows wood structural panels at least 7/16 inch thick with a span of not more than 8 feet, precut and attached to the framing around the opening with permanent corrosion-resistant anchors. Its fastening table applies to buildings with a mean roof height of 45 feet or less where Vult is 180 mph or less:
| Fastener type (2-inch embedment) | Panel span 4 ft or less | Over 4 ft to 6 ft | Over 6 ft to 8 ft |
|---|---|---|---|
| No. 8 wood-screw-based anchor | 16 in. | 10 in. | 8 in. |
| No. 10 wood-screw-based anchor | 16 in. | 12 in. | 9 in. |
| 1/4-inch lag-screw-based anchor | 16 in. | 16 in. | 16 in. |
Table notes in the 2024 IRC: fasteners go at opposing ends of the panel, at least 1 inch from the panel edge; anchors must penetrate the wall covering with at least 2 inches of embedment in the frame; fasteners must be at least 2.5 inches from the edge of concrete block or concrete; and panels on masonry or masonry with stucco need vibration-resistant anchors with an ultimate withdrawal capacity of at least 1,500 pounds.
A footnote to the 2024 IRC table says it is based on a 180 mph ultimate design wind speed and a 45-foot mean roof height, so a taller building or a higher design wind speed needs attachments designed under the code instead of the table.
Because TDI now uses the 2024 IRC for windstorm certification (effective April 1, 2026), check this section against the 2024 edition your inspector uses before you build, and ask TDI or your appointed engineer whether plywood will be accepted for a Form WPI-8 on your project. TDI's Windstorm line is 800-248-6032, option 3. See Texas windstorm certification for windows.
Florida vs. Texas plywood rules at a glance
| Florida (FBC 2023, outside HVHZ) | Texas windstorm areas (IRC, per TDI) | |
|---|---|---|
| Minimum thickness | 7/16 inch | 7/16 inch (2024 IRC) |
| Span | 44 inches between lines of fasteners | Up to 8 feet (2024 IRC) |
| Building limit | Mean roof height 33 ft or less; Vult 180 mph or less | Table applies at mean roof height 45 ft or less; Vult 180 mph or less (2024 IRC) |
| Fastener rule | Designed, or 16 in. on center along opposing long sides | Designed, or the fastening table by span |
| Permanent anchors | Required | Required |
| Not allowed | HVHZ (Miami-Dade, Broward) | Ask TDI; acceptance for WPI-8 depends on installation |
| Insurance | Level C on OIR-B1-1802 if it meets the 2007 FBC table | Ask your insurer or TWIA |
Buying plywood when a storm is coming
Plywood sells out fast once a storm is forecast, and buying it late usually means no time to precut, drill and install anchors, so it will not meet the code exception anyway. If you do buy during a declared emergency, both states protect you from gouging. Florida's s. 501.160 makes it unlawful to sell essential commodities, expressly including lumber, at an unconscionable price in the emergency area after the Governor declares a state of emergency. Texas's DTPA (Bus. and Com. Code 17.46(b)(27)) prohibits exorbitant or excessive prices for building materials during a declared disaster. Report problems to your state Attorney General.
Do I need a permit to install permanent anchors?
It depends on your city or county. Permanent anchors are part of opening protection, and some building departments treat shutter systems as permitted work while others may not require a permit for owner-installed panels. Call your building department before you drill, and ask what they need. A permit and inspection also give you a record to show an insurance inspector. For Florida permit basics, see hurricane window permits in Florida.
How to choose a provider
- Confirm you are outside Miami-Dade and Broward (the HVHZ) if relying on plywood in Florida.
- Ask the building department for your design wind speed and whether a permit is needed.
- Measure every opening and check it against the 44-inch span limit (Florida).
- Buy structural plywood or OSB at least 7/16 inch thick.
- Precut each panel to overlap at least 2 inches beyond the fastener lines.
- Install corrosion-resistant permanent anchors with the required withdrawal and shear ratings.
- Predrill panels to match anchors and test-fit each one.
- Use 1/4-inch minimum nuts or bolts with 1-inch washers.
- Label panels and hardware, and print a house map.
- Seal panels and store them flat and dry.
- Show panels and anchors to your wind mitigation inspector.
- In Texas, confirm WPI-8 acceptance with TDI or your appointed engineer before you build.
Related hurricane shutters and impact windows guides
- Which Hurricane Storm Panels Are Best: Steel, Aluminum or Clear Polycarbonate?
- What Is the HVHZ? Hurricane Protection Rules in Miami-Dade and Broward vs. the Rest of Florida
- Wind Mitigation Form OIR-B1-1802: How Is Opening Protection Graded (Classes A, B, C, N, X)?
- When Should You Put Up Hurricane Shutters? Watch vs. Warning, How Long It Takes, and a Last-Minute Checklist
- Do You Need a Texas Windstorm Certificate (WPI-8) for New Windows, Doors or Shutters?
- What Are the Types of Hurricane Shutters? Accordion, Roll-Down, Panels, Fabric, Colonial and Bahama Compared
- Florida Building Code Opening Protection Rules: When Is Impact Protection Required?
Hurricane shutters and impact windows by state and city
Questions people ask
Is plywood legal for hurricane protection in Florida?
Yes, outside Miami-Dade and Broward, if it meets the Florida Building Code wood structural panel exception: at least 7/16 inch thick, 44-inch span between fastener lines, mean roof height 33 feet or less, design wind speed 180 mph or less, precut, predrilled, and fastened to permanently installed corrosion-resistant anchors. Loose sheets nailed up at the last minute do not meet it.
What thickness of plywood do I need for hurricane shutters?
At least 7/16 inch under both the Florida codes and the IRC. Thicker sheets such as 5/8 inch are allowed but heavier, and they must still follow the same span, overlap and anchor rules. Do not use thinner panels.
Can I use OSB instead of plywood?
Yes. The code says wood structural panels, which include plywood and oriented strand board. The Florida wind mitigation form groups plywood and OSB together at level C. Keep OSB dry, since it can swell when wet, and check that it still lines up with your anchors each year.
Is plywood allowed in Miami-Dade or Broward?
Not as code-level protection. Buildings in the High-Velocity Hurricane Zone follow FBC Sections 1616 to 1626, which require impact-tested products or devices. The wood panel exception in Section 1609 does not apply there. Plywood may be a temporary stopgap after damage, but use NOA or Florida-approved products for real protection.
How far apart should plywood fasteners be?
In Florida, the prescriptive option is 16 inches on center along the edges of the two opposing long sides, 2 inches in from the panel edge. In Texas, the 2024 IRC table ranges from 16 inches down to 8 inches depending on panel span and anchor type. Designed attachments are also allowed.
Do plywood clips meet code?
We found no Florida code provision that accepts clips under the wood panel exception, which calls for panels fastened to permanently installed anchors around the opening. If a clip product claims approval, check its product approval or NOA and its limits. Otherwise treat clips as an emergency measure only.
Will plywood get me an insurance discount?
Possibly a small one. On Florida's OIR-B1-1802 form, plywood or OSB meeting the 2007 FBC table rates level C, below tested shutters at A or B. Every glazed opening must have a panel, because the weakest opening sets the grade. Show the inspector the panels and anchors.
Can I cover a sliding glass door with plywood?
Usually not within the prescriptive Florida exception, because sliders are wider than the 44-inch span in both directions once height is considered. Use approved shutters or panels sized for the opening, or impact glass, or get an engineered design approved by your building department.
Does Texas accept plywood for a WPI-8?
TDI says wood structural panel shutters may be possible depending on secure attachment, safe handling and permanent fasteners in the wall framing, and it points to 2024 IRC R301.2.1.2. Ask TDI at 800-248-6032, option 3, or your appointed engineer before building, so you know it will be accepted.
Sources
- Florida Building Code, Building 8th Ed. (2023), Chapter 16 Structural Design, 1601.1, 1609.1.2, 1626 (UpCodes)
- Florida Building Code, Residential 8th Ed. (2023), Chapter 3, R301.2.1.2 (UpCodes)
- International Residential Code 2021 as published for Texas, Chapter 3, R301.2.1.2 and Table R301.2.1.2 (UpCodes)
- Florida Building Commission (BCIS) home page: code edition status
- Form OIR-B1-1802, Uniform Mitigation Verification Inspection Form (Rev. 04/26)
- Citizens: Your Wind Inspection
- Texas Department of Insurance: Making repairs after a storm
- Texas Department of Insurance: Questions to Ask Your Contractor Before Installing Opening Protection
- Texas Department of Insurance: Windstorm general questions
- Texas Department of Insurance: Adopted building codes
- Florida Statutes 501.160, Rental or sale of essential commodities during a declared state of emergency
- Texas Business and Commerce Code Chapter 17 (DTPA)
- DBPR, 2026 FBC Update: State Product Approval and the FBC 9th Edition (June 30, 2026)
- 2024 International Residential Code (Texas), Section R301.2.1.2 and Table R301.2.1.2, via UpCodes
This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.


