On Florida's 2026 wind mitigation form (OIR-B1-1802 Rev. 04/26), question 9 grades the weakest opening protection on the home. Class A means every glazed opening has verified, listed protection tested with a 9-pound missile; B uses lighter missile tests; C is verified plywood or OSB; N is protection that cannot be verified; X means at least one opening is unprotected. A sub-number (.1, .2, .3) rates solid entry and garage doors.

Key facts

  • OIR rule 69O-170.0155, amended effective April 1, 2026, adopts Form OIR-B1-1802 Rev. 04/26.
  • On the 2026 form, opening protection is question 9 and is graded by the WEAKEST protection on any glazed opening.
  • Level A: verified cyclic pressure and large missile, 9 lb for windows and doors, 4.5 lb for skylights; Level B: 4 to 8 lb for windows and doors; for skylights the form's level chart says 2 lb while its Level B answer text says 2 to 4.5 lb.
  • Level N means protection that appears to be A or B but is unverified; X means no protection; Z means damaged openings.
  • Openings needing replacement disqualify the home from wind mitigation rate differentials (2026 form).
  • At least one photo or document must support each attribute in questions 2 through 9.
  • Inspectors allowed under s. 627.711(2)(a): licensed home inspectors with 3 hours of approved training, building code inspectors, licensed contractors, engineers, architects, or others the insurer accepts.
  • Citizens: wind mitigation forms are usually valid up to five years.
  • OIR's proposed Form OIR-B1-600 was in rulemaking in 2026 (workshop May 19, notice of change September 2).

What is the OIR-B1-1802 wind mitigation form?

Form OIR-B1-1802 is Florida's Uniform Mitigation Verification Inspection Form, usually called the "wind mit" form. A qualified inspector fills it out after looking at your home's roof, roof-to-wall connections, roof shape, secondary water barrier and opening protection. You send it to your insurance agent, and the insurer uses it to apply the windstorm discounts that Florida law requires insurers to offer.

Section 627.711(2)(a) of the Florida Statutes directs the Financial Services Commission to adopt one uniform form that "shall be used by all insurers" for wind discounts. The Office of Insurance Regulation (OIR) adopts it by rule 69O-170.0155.

The current version: Rev. 04/26

Rule 69O-170.0155 was amended effective April 1, 2026 to adopt OIR-B1-1802 "Rev. 04/26," replacing the version that had been in use since the early 2010s. If an article, inspector checklist or video describes questions by number, check that it uses the 2026 form. On the 2026 form, opening protection is question 9. Many older guides call it question 7 because they describe the earlier layout.

More change may be coming. OIR held a workshop on May 19, 2026 on rule 69O-170.0155 and a proposed new Form OIR-B1-600, "Uniform Mitigation Verification Form Report," and published a notice of change on September 2, 2026. As of November 19, 2026 that proposal was still in rulemaking. Check the rule page on flrules.org before relying on any form detail.

What the 2026 form asks

QuestionTopic
1Building code in force at original permit (FBC 2001/2004, FBC 2007 or later, or SFBC-94 in the HVHZ)
2Region: HVHZ, Region 1 (140 mph or more), Region 2 (130 to 139 mph) or Region 3 (under 130 mph), based on ASCE 7-22 Risk Category 2 speeds
3Roof slope
4Roof covering and product approval
5Roof deck attachment
6Roof-to-wall attachment
7Roof geometry (hip, flat, other)
8Sealed roof deck or secondary water resistance
9Opening protection

How question 9 grades opening protection

Question 9 asks: "What is the WEAKEST form of wind-borne debris protection installed on the structure?" It covers "all openings in the wall and roof including windows, doors, sliding glass doors, skylights, and garage doors." Gable roof vents and other roof vents are not included.

The inspector fills in a chart, marking each type of protection in use for each opening type. The chart has separate columns for glazed openings (windows or entry doors, garage doors, skylights, glass block) and non-glazed openings (entry doors, garage doors).

The level chart

LevelWhat the 2026 form says
N/ANo openings of this type on the structure
AVerified cyclic pressure and large missile (9 lb for windows and doors, 4.5 lb for skylights)
BVerified cyclic pressure and large missile (4 to 8 lb for windows and doors, 2 lb for skylights)
CVerified plywood or OSB meeting Table 1609.1.2 of the FBC 2007
DVerified non-glazed entry or garage doors showing compliance with ASTM E 330, ANSI/DASMA 108 or PA/TAS 202 for wind pressure resistance
NProtection products that appear to be A or B but are not verified, or other coverings that cannot be identified as A, B or C
XNo windborne debris protection
ZDamaged openings in need of repair or replacement

The answer you get (Class A, B, C, N, X or Z)

Your overall answer is set by the weakest glazed opening. One unprotected window makes the whole house "X." The form's answer options are:

  • A. All glazed openings protected with products listed in the Florida or Miami-Dade product approval system that meet Miami-Dade PA 201, 202 and 203; FBC TAS 201, 202 and 203; ASTM E1886 and E1996; or SSTD 12 (skylights: ASTM E1886 and E1996; garage doors: ANSI/DASMA 115). The factor table calls this "Hurricane."
  • B. All glazed openings protected with listed products meeting ASTM E1886 and E1996 with a 4.5-lb large missile, SSTD 12 with a 4 to 8 lb missile, or, for skylights, a 2 to 4.5 lb missile. Also "Hurricane" in the factor table.
  • C. All glazed openings covered with plywood or OSB meeting FBC 2007 Table 1609.1.2 ("Plywood or OSB").
  • N. All glazed openings covered, but at least one with a product that is unverified or not identifiable as A, B or C ("Ordinary").
  • X. One or more glazed openings with no protection ("None").
  • Z. One or more openings damaged and needing repair or replacement.

What are A.1, A.2 and A.3?

The number after the letter records the non-glazed doors (solid entry doors and solid garage doors):

Sub-answerMeaning (Class A example)
A.1All non-glazed openings are also Level A, or there are no non-glazed openings
A.2One or more non-glazed openings are Level D (wind-pressure rated only), and none are B, C, N or X
A.3One or more non-glazed openings are Level B, C, N, X or Z

B.1 to B.3, C.1 to C.3 and N.1 to N.3 follow the same pattern. A home can have impact windows throughout and still land at A.3 because of an old solid garage door. Upgrading that door can move the sub-answer up.

Do all openings need to be protected to get credit?

For a glazed-opening rating of A, B or C, yes. Each of those answers starts with "All glazed openings are protected" or "covered." If even one window, sidelight, transom, skylight or glass garage door panel is unprotected, the answer drops to X. If they are all covered but one uses an unverified product, the answer is N.

Two other rules apply to every home:

  • Good condition. The form says, "All openings (windows, doors, and skylights) must be in good condition. Buildings with openings that need replacement do not qualify for wind mitigation rate differentials, regardless of the presence/absence of other features." A cracked impact pane or a rotted door can cost you more than the opening credit.
  • Proof for each attribute. "At least one photograph or document providing proof must accompany this form to validate each attribute marked in questions 2 through 9."

Does the garage door count?

Yes. Garage doors appear twice in the chart: as glazed openings if they have glass, and as non-glazed openings if solid. A glass garage door panel without impact protection makes the glazed answer X. A solid garage door that is only wind-pressure rated (ASTM E 330, ANSI/DASMA 108 or TAS 202) is Level D, which pushes the sub-answer to .2. For top credit, a garage door should be impact rated (ANSI/DASMA 115) and documented. See our garage door guide.

Do skylights count?

Yes. Skylights have their own column and their own missile weights: 4.5 lb for Level A, 2 lb in the Level B chart, and 2 to 4.5 lb under the Level B answer text. An unprotected skylight drops the home to X just like a window. See skylights and other openings.

Does plywood count?

It can count as Level C, but only if it is verified plywood or OSB meeting FBC 2007 Table 1609.1.2 and covers all glazed openings. That means correctly sized, precut panels with the required fasteners. Loose sheets in the garage with no anchors generally will not qualify. Insurers treat C as a lower tier than A or B ("Plywood or OSB" in the secondary factors table, versus "Hurricane"). See our plywood guide.

Why did my inspector mark N instead of A?

"N" usually means the inspector saw shutters or impact windows that look right but could not prove what they are. The form's own words: systems "that appear to meet Answer 'A' or 'B' with no documentation of compliance." Common reasons:

  • No visible product label, or labels painted over or removed.
  • No permit record, NOA or Florida approval number available.
  • Removable panels stored elsewhere and not shown to the inspector.
  • Mixed protection where one product type is undocumented.
  • Older shutters with approvals that cannot be matched to the installed product.

How to fix N to A

  1. Find the approval number. Look for permanent labels. FBC 1709.9.3 puts accordion shutter labels on the bottom of the locking bar or center mate, and roll-up labels on the bottom of the hood or bottom slat, facing out. Windows carry labels under FBC 1709.5.1.
  2. Pull your permit records. The building department's permit file often lists the product approvals used. Many counties and cities, such as Orlando, offer online permit lookup by address.
  3. Ask the installer or manufacturer for the Notice of Acceptance or Florida approval letter. Citizens Property Insurance specifically recommends giving inspectors "Notice-of-acceptance letters for mitigation products (usually obtained from installers or manufacturers)."
  4. Look up the approval on floridabuilding.org or the Miami-Dade Product Control search and print it. See our product approval lookup guide.
  5. Gather receipts with product specifications. Citizens lists these as useful documents.
  6. Bring out stored panels. Citizens tells owners to make stored storm shutters or panels available to the inspector.
  7. Ask for a revised form or a new inspection with the documents attached.

What documentation proves my shutters or impact windows are rated?

DocumentWhy it helps
Florida product approval (FL number) or Miami-Dade NOALevel A and B require products "listed as wind borne debris protection devices in the product approval system of the State of Florida or Miami-Dade County"
Product labels (photographed)FBC labels must show the approval number and test standards
Building permit and final inspection recordShows the product was permitted and inspected as installed
Installer invoice or receipt with model numbersTies the label or approval to your home
FORTIFIED Home certificate (Roof, Silver or Gold)The 2026 form says a FORTIFIED certificate "may be used to validate the attributes marked in questions 4 through 6, and questions 8 through 9"
Photos of each openingThe form requires at least one photo or document per attribute

Keep these in one folder, with digital copies. You will need them again in five years, when you sell, or if your insurer re-verifies.

Who can perform a wind mitigation inspection?

Under s. 627.711(2)(a), insurers must accept a form signed by:

  1. A home inspector licensed under s. 468.8314 who has completed at least 3 hours of hurricane mitigation training approved by the Construction Industry Licensing Board, including the form, and a proficiency exam.
  2. A building code inspector certified under s. 468.607.
  3. A general, building or residential contractor licensed under s. 489.111.
  4. A professional engineer licensed under s. 471.015.
  5. A professional architect licensed under s. 481.213.
  6. Any other person the insurer recognizes as qualified.

The signer must personally inspect the home. Only licensed contractors and professional engineers may send a qualified direct employee (not an independent contractor), and they are directly liable for that employee's work, under s. 627.711(3) and (5). The 2026 form has the homeowner sign that the inspector performed the inspection and showed identification.

Citizens warns that a form may be rejected if the right professional did not inspect or if the professional's Florida license "is not active or cannot be verified." Check a license on the DBPR licensing site before you book. Section 627.711(6) bars inspectors from paying insurance agents for referrals, and bars agents from accepting.

Fraud warnings on the form

  • Knowingly providing a false form to obtain an unearned discount is a first-degree misdemeanor under s. 627.711(8).
  • Inspectors who sign false forms or are grossly negligent can be investigated by the Division of Criminal Investigations and disciplined by their licensing board, under s. 627.711(4), (5) and (7).

How much does an inspection cost, and how long is the report valid?

No Florida law sets a price for a wind mitigation inspection. Inspectors set their own fees, so get a quote. Section 627.0629(2) notes that when an insured requests an inspection, the insurer may require the insured to pay its reasonable cost. Free inspections have been available through My Safe Florida Home when the program is funded. As of November 19, 2026, the program's site says the applicant portal has been offline since November 10 while it moves to a new platform. See our My Safe Florida Home guide.

Five years, with exceptions

Section 627.711(2)(a) tells the Financial Services Commission to give guidance on how long results are valid. Citizens Property Insurance says forms "usually are valid for up to five years from the date of the inspection form." You may need a new one sooner if you add mitigation features such as new impact windows, make structural changes such as a new roof or an addition, or file certain claims.

Can I appeal or redo a wind mitigation inspection?

There is no formal state appeal of an inspector's answer. Your options are practical:

  • Ask the same inspector to revise the form when you supply missing documents.
  • Hire another qualified inspector for a new form.
  • If your insurer orders a verification inspection and you disagree, Citizens says your agent should submit documentation "that clearly shows why a discrepancy noted in the verification inspection report is inaccurate."
  • If your insurer still refuses a discount you believe the documents support, ask the agent for the reason in writing; a licensed public adjuster or attorney can advise on next steps.

Insurers may re-verify forms at their own expense through an independent inspector or quality assurance provider, under s. 627.711(9). Citizens' website cites this right as subsection (8); in the current statute it appears in subsection (9). Citizens cannot re-inspect, absent material changes, if the form went through a Citizens-approved quality assurance program before submission.

From form to discount: what happens after the inspection

  1. The inspector gives you the completed form with photos and documents.
  2. You send it to your insurance agent, who submits it to the insurer. Citizens says it will "review your inspection results and apply any appropriate mitigation discounts."
  3. The insurer must report the form's data to OIR's web portal within 60 days, without your name, phone or email, under rule 69O-170.0155(3).
  4. If new discounts are approved after you update features, Citizens says you will receive a revised policy notice.

The discount applies to the hurricane (wind) portion of your premium. Section 627.0629(4) requires Florida residential premium notices to show the hurricane premium separately. See our insurance discounts guide for why a premium may not drop as much as expected.

Condos and commercial buildings use different forms

Citizens uses OIR-B1-1802 for single-family homes, one-to-four-unit dwellings and residential buildings of one to three stories. Condo unit owners and commercial residential applicants in buildings of four or more stories use the Building Type II and III Mitigation Inspection Form (MIT-BT II and III). Commercial nonresidential buildings use the Commercial Windstorm Protective Device Proof of Compliance (WPD-1C) to confirm opening protection.

Texas: is there a wind mitigation form?

Texas has no OIR-style statewide form. On the coast, opening protection credit runs through TDI windstorm certification. TDI says TWIA offers discounts for new homes built to the IRC or IBC and "a discount is available for existing structures that retrofit their exterior openings with Windborne debris resistant products." You can install products a few openings at a time: each installation needs an inspection, and a Texas-licensed engineer files a WPI-2-BC form each time, checking a box on the final one to tell TDI all openings are protected.

In September 2026, TDI's Commissioner's Bulletin B-0008-26 encouraged insurers to offer actuarially supported mitigation discounts and asked them not to burden consumers with "separate, redundant loss mitigation surveys or inspection forms." It set no discount amounts. TDI's opening protection FAQ adds that discounts "will vary from one company to another." Ask your agent what proof your insurer accepts. See our TWIA coverage guide.

How to choose a provider

  • Gather approval numbers, NOA letters, permits and receipts before the inspection.
  • Photograph every window, door, skylight and garage door label.
  • Get stored panels out and clear attic access.
  • Fix cracked glass or damaged doors first; damaged openings disqualify discounts.
  • Verify the inspector's Florida license.
  • Review the completed form: check question 9 and the sub-answer.
  • If marked N, supply documents and ask for a revised form.
  • Send the form to your agent and confirm the discount was applied.
  • Calendar a new inspection before five years or after any upgrade.

Related hurricane shutters and impact windows guides

Hurricane shutters and impact windows by state and city

Questions people ask

What is question 7 opening protection on the wind mit form?

On older versions of the form, opening protection was question 7. On the current OIR-B1-1802 Rev. 04/26, adopted effective April 1, 2026, it is question 9, after new questions on region and roof slope. It asks for the weakest form of windborne debris protection on all windows, doors, sliding doors, skylights and garage doors, graded A, B, C, N, X or Z, with sub-answers for non-glazed doors.

What is the difference between Class A and Class B?

Both mean every glazed opening is protected with listed products that passed cyclic pressure and large missile tests. Class A requires the 9-pound missile for windows and doors (4.5 pounds for skylights), or standards such as TAS 201/202/203 or ASTM E1886/E1996. Class B covers lighter missile tests, such as ASTM with a 4.5-pound missile or SSTD 12 with 4 to 8 pounds. Both are Hurricane in the factor table.

Can I get credit if only some windows have shutters?

Not for opening protection. Answers A, B and C each require all glazed openings to be protected. One unprotected glazed opening makes the answer X. You can still earn credit for roof features on the same form. If you are protecting a few openings at a time, finish the set before ordering a new inspection, then send the updated form to your agent.

Do impact windows count the same as shutters?

Yes, if verified. The form rates the protection, not the type. Impact windows tested to the listed standards and listed in the Florida or Miami-Dade approval system qualify for A or B just as approved shutters do. The proof needed is the same: labels, approval numbers, permits or NOA letters. Damaged impact glass, though, is Z and removes eligibility for discounts until repaired.

My house was built in 2010. Will the inspector assume my windows are protected?

No. The form asks for proof of each attribute. Code year matters for question 1, but question 9 needs evidence of the actual protection. If your home is in an area that required protection, there may be permit records or labels to find. Many homes outside the windborne debris region were built without any. The inspector marks what can be verified.

Does a FORTIFIED certificate replace the wind mit inspection?

Not entirely. The 2026 form says a FORTIFIED Home Roof, Silver or Gold certificate may be used to validate attributes in questions 4 through 6 and 8 through 9, and a photocopy is attached to the form. The inspector still completes the form. FORTIFIED certification is a separate program run by IBHS. See our FORTIFIED guide for what each level requires.

Does the inspector need to see stored hurricane panels?

Yes. Panels that are not installed must be shown so the inspector can identify them and their labels. Citizens tells policyholders to ensure their representative knows where to find attic access and any stored storm shutters or panels. Pre-marked panels with a layout plan, which TDI also recommends for removable shutters, make this easier and speed up storm setup.

Does the form apply to condos?

OIR-B1-1802 is used for single-family homes and, at Citizens, for one-to-four-unit dwellings and residential buildings of one to three stories. For condo units in buildings of four or more stories, Citizens requires the MIT-BT II and III form. Ask your association whether it has a building-wide mitigation report, since windows and shutters may be association or owner responsibility under the declaration.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration