Do Skylights, Vents, Glass Block and Other Openings Need Hurricane Protection?
The openings people forget: skylights and tubular skylights, glass block, transoms, sidelights, small bathroom windows, gable and soffit vents, roof turbines, louvers, dryer vents, jalousies and pet doors. What the Florida and Texas codes require, what the wind mitigation form counts, and how one forgotten opening can cost you your discount.
Yes, most do. In Florida's wind-borne debris region every glazed opening, including skylights, glass block, transoms, sidelights and small bathroom windows, must be impact rated or protected, and in Miami-Dade and Broward the code names skylights and glass block outright. Florida's wind mitigation form rates the house by its weakest opening and counts windows, doors, skylights and garage doors, but not gable or roof vents. Vents still matter for wind-driven rain, which FORTIFIED addresses with gable vent covers.
Key facts
- Florida's 2026 mitigation form (OIR-B1-1802 Rev. 04/26) counts all openings in the wall and roof, including windows, doors, sliding glass doors, skylights and garage doors, and excludes gable and other roof vents.
- On the form, Level A uses a 9-lb large missile for windows and doors but a 4.5-lb missile for skylights; Level B uses a 4 to 8 lb missile for windows and doors; for skylights the form's level chart says 2 lb while its answer text says 2 to 4.5 lb.
- The form's opening protection chart has separate glazed-opening columns for windows or entry doors, garage doors, skylights and glass block.
- FBC 1626.1 lists outside doors, skylights, glazing and glass block among the HVHZ envelope parts that must meet impact criteria or be protected.
- FBC 1626.1 exempts soffits, soffit vents, ridge vents, vents in garages for four or fewer cars, HVAC wall and roof openings and roof hatches from HVHZ impact testing.
- FBC Residential R308.6.9 requires unit skylights and tubular daylighting devices to be tested and labeled to AAMA/WDMA/CSA 101/I.S.2/A440.
- The U.S. DOE Building America guide states that opening protection for skylights is not available, so skylights should be impact and pressure rated.
- The 2025 FORTIFIED Home standard requires removable shutters on gable end vents for Hurricane designations and does not permit vented gable end rake soffits.
- TDI says skylights, roof vents and roof turbines are vulnerable to high winds and hail and recommends impact-resistant skylights tested to ASTM E1886 and E1996.
- FEMA's Hurricane Ian assessment found water intrusion primarily through sliding glass doors and soffits.
Why the openings you forget matter most
A house in a hurricane behaves like a balloon. As long as the envelope is closed, wind pushes and pulls on the outside. Once any opening breaks, wind rushes in and pressurizes the inside, pushing up on the roof and out on the walls. The Insurance Institute for Business and Home Safety (IBHS) describes exactly that sequence for broken windows and garage doors. It does not matter whether the breach is a picture window or a small skylight.
The smaller openings also cause trouble for a second reason: insurance. Florida's wind mitigation form rates opening protection by the weakest glazed opening on the house. A home with impact windows everywhere except one unprotected skylight, one old bathroom window or one transom over the front door is rated as if it had no protection at all. That is the most common reason homeowners who spent heavily on impact windows are surprised by a poor inspection result.
This guide walks through every opening type, what the Florida Building Code (8th Edition, 2023) and Texas windstorm rules require, how each is treated on the 2026 mitigation form, and what to do about it.
Does your home need opening protection at all? Check your region
Every rule on this page depends on where the house sits. The Florida Building Code defines two areas:
- Hurricane-prone regions: the Atlantic and Gulf coasts where the ultimate design wind speed (Vult) for ordinary Risk Category II buildings is greater than 115 mph.
- Wind-borne debris region: the part of the hurricane-prone region within 1 mile of the coastal mean high water line where Vult is 130 mph or more, or anywhere Vult is 140 mph or more. This is where glazed openings must be impact resistant or protected.
Inside the debris region, the code sets the missile by height: glazed openings within 30 feet of grade must pass the ASTM E1996 large missile test, and openings more than 30 feet up must pass the small missile test (FBC 1609.1.2). FBC 1609.1.2.2 also assigns ASTM E1996 wind zones by wind speed: Zone 1 (130 to under 140 mph), Zone 2 (140 to under 150 mph more than a mile from the coast), Zone 3 (150 to 170 mph, or 140 to 170 mph within a mile of the coast) and Zone 4 (above 170 mph). Higher zones mean tougher test levels, which is why a skylight approved for an inland Zone 1 site may not be approved for a beachfront Zone 3 or 4 site.
In Miami-Dade and Broward, the HVHZ rules apply countywide regardless of these lines. Florida's 2026 mitigation form adds a Region question (HVHZ, Region 1 at 140 mph or more, Region 2 at 130 to 139 mph, Region 3 under 130 mph). Ask your building department for your site's design wind speed before buying products for small openings. In Texas, TDI says the wind speed must be set for each structure, for example with the ASCE 7 Hazard Tool. See Florida Building Code opening protection.
How the forgotten openings compare: HVHZ, rest of Florida and Texas
| Opening | HVHZ (Miami-Dade, Broward) | Florida debris region outside HVHZ | Texas catastrophe area |
|---|---|---|---|
| Skylights | Named in FBC 1626.1; impact criteria required | Glazed opening; impact resistant or protected | TDI: test to ASTM E1886 and E1996; product listings at TDI |
| Glass block | Named in FBC 1626.1 | Glazed opening rules apply | Glazed opening under 2024 IRC/IBC debris rules |
| Transoms, sidelights, small windows | All glazing covered | Glazed openings; no size exemption | Glazed openings; all openings needed for TWIA retrofit credit |
| Wall louvers | FBC 1626.5: AMCA 540 or TAS 201, plus TAS 202 and 203 or AMCA 540 | FBC 1609.1.2.1: AMCA 540 or covered, within 30 ft of grade | Per 2024 IRC/IBC |
| Soffit and ridge vents | Exempt from impact tests (1626.1) | Product approval for soffits (1709.10) | Roof vents: choose wind-rated products (TDI) |
| Gable vents | Not on FL mitigation form; FORTIFIED covers | Same | Gable end bracing recommended (TDI) |
| Garage vents (4 or fewer cars) | Exempt from impact tests, size limits apply | Not addressed separately | Not addressed separately |
What openings does Florida's wind mitigation form count?
Question 9 of the Uniform Mitigation Verification Inspection Form (OIR-B1-1802, Rev. 04/26, effective April 1, 2026) asks: "What is the WEAKEST form of wind-borne debris protection installed on the structure?" It says the category "includes all openings in the wall and roof including windows, doors, sliding glass doors, skylights, and garage doors. Gable roof vents and other roof vents are not included."
The inspector fills in a chart with these columns:
| Glazed openings | Non-glazed openings |
|---|---|
| Windows or entry doors (including sliders, French doors and glass in doors) | Entry doors |
| Garage doors with glass | Garage doors |
| Skylights | |
| Glass block |
For each column the inspector marks every form of protection present, from best to worst:
| Level | Meaning |
|---|---|
| A | Verified cyclic pressure and large missile: 9 lb for windows and doors, 4.5 lb for skylights |
| B | Verified cyclic pressure and large missile: 4 to 8 lb for windows and doors, 2 lb for skylights (the answer text says 2 to 4.5 lb) |
| C | Verified plywood or OSB meeting Table 1609.1.2 of the 2007 FBC |
| D | Verified non-glazed entry or garage doors rated for wind pressure (ASTM E330, ANSI/DASMA 108 or PA/TAS 202) |
| N | Products that appear to be A or B but are not verified, or other coverings that cannot be identified as A, B or C |
| X | No wind-borne debris protection |
| Z | Damaged openings needing repair or replacement |
The overall answer is set by the lowest row checked for any glazed opening. Non-glazed doors set a sub-answer (for example, A.1, A.2 or A.3). Three more rules on the form matter here:
- All openings must be in good condition. Homes with openings needing replacement do not qualify for wind mitigation rate differentials "regardless of the presence/absence of other features."
- Level A and B products must be listed in the Florida or Miami-Dade product approval system. For skylights, the listed standards are ASTM E1886 and E1996.
- The inspector must have at least one photo or document proving each attribute marked.
Full walkthrough: the wind mitigation form and opening protection.
Do skylights need impact protection?
In most of coastal Florida, yes, and in practice that means an impact-rated skylight.
- The code. Skylights are glazed openings. In wind-borne debris regions, FBC 1609.1.2 and Residential R301.2.1.2 require glazed openings to be impact resistant or protected. In the HVHZ (Miami-Dade and Broward), FBC 1626.1 names skylights specifically. FBC Existing Building 707.4 requires replacement skylights to comply with Chapter 16.
- Pressure and labeling. FBC Residential R308.6.9 requires unit skylights and tubular daylighting devices to be tested by an approved independent lab and labeled to AAMA/WDMA/CSA 101/I.S.2/A440. FBC Building 1709.6 sends skylights to Chapter 24 of the code.
- Glass. R308.6.2 lists permitted skylight glazing: laminated glass with at least a 0.015-inch PVB interlayer for panes 16 square feet or less with the top no more than 12 feet above a walking surface (0.030 inch for larger or higher), fully tempered glass, heat-strengthened glass, wired glass and approved rigid plastics. Tempered and heat-strengthened glass may need a broken-glass retention screen below.
- Curbs. On roofs flatter than 3-in-12, unit skylights must sit on a curb at least 4 inches above the roof unless the manufacturer's instructions say otherwise (R308.6.8).
Why not shutter a skylight? The U.S. Department of Energy's Building America guide states that opening protection for skylights is not available, so skylights should be impact and pressure rated. FLASH (the Federal Alliance for Safe Homes) adds that non-rated skylights are hard to protect in advance: covering them before a hurricane is inconvenient, and protecting them before a hailstorm is nearly impossible. FLASH recommends wind- and impact-rated units with the design pressure required for your location.
Field evidence. FEMA's post-hurricane review in the U.S. Virgin Islands found airport terminal skylights broken by wind-borne debris and corroded attachment screws, and stressed the importance of specifying skylights tested to debris criteria.
Skylight missile weights on the mitigation form
Skylights get their own missile weights on Florida's form, because a skylight on a roof is hit by different debris than a wall window:
| Level | Windows and doors | Skylights | Standards listed for skylights |
|---|---|---|---|
| A | 9-lb large missile | 4.5-lb large missile | ASTM E1886 and ASTM E1996 |
| B | 4 to 8 lb large missile | 2 lb (chart) / 2 to 4.5 lb (answer text) | ASTM E1886 and ASTM E1996 (large missile 2 to 4.5 lb) |
Note the small inconsistency on the official form: the level chart lists 2 lb for skylights at Level B, while the answer text says 2 to 4.5 lb. Either way, a skylight tested to the 4.5-lb missile qualifies for A, and one tested only to a lighter missile lands in B. An untested skylight is X, which drags the whole house to X no matter how good the windows are.
Practical tip: ask your skylight supplier for the approval showing the missile weight. Keep that document for the inspector, because skylight labels are hard to see from inside and impossible from the ground.
Are tubular skylights impact rated?
Some are. Tubular daylighting devices (TDDs), the small round dome-and-tube skylights, are a defined term in the Florida Building Code, Residential, and R308.6.9 requires them to be tested and labeled to AAMA/WDMA/CSA 101/I.S.2/A440, the same as unit skylights. That standard covers pressure and water, not debris impact.
We found no rule that treats a tubular skylight differently from a unit skylight for wind-borne debris. It is a glazed opening in the roof, so in the wind-borne debris region and the HVHZ it needs impact resistance, and on the mitigation form it falls in the skylight column. Before you buy, search the Florida product approval system or Miami-Dade's Product Control Search (category Skylights, subcategory Skylights - Units) for the specific dome and confirm it lists impact testing. An unrated dome on an otherwise protected house can turn an A rating into an X.
Replacing or protecting existing skylights
- Timing. FLASH recommends replacing skylights during re-roofing, when removing the old roofing gives easy access.
- Removing instead of replacing. Some owners remove an old skylight and deck over the opening. That is roof work, so check the permit requirements and have the decking and roof covering installed to current code.
- Grant help. Florida's My Safe Florida Home grants may pay for skylights as opening protection when the program's inspection recommends them, and DFS may require improvements to all openings, including skylights, as a condition of reimbursement (Florida Statutes 215.5586). The applicant portal has been offline since November 10, 2026 for a platform move.
- Hail. FORTIFIED's 2025 standard has a separate hail supplement for skylights (Section 7.4). If you are in a hail-prone part of Texas, ask about hail ratings too.
- Permit fees. Unincorporated Miami-Dade's October 2026 fee schedule includes a shop drawing review fee for skylights of $92.34 for the first five plus $20.52 for each additional skylight, in addition to the building permit.
Do not try to make a shutter for a skylight out of plywood screwed into the roof. Holes through the roof covering create leak points and the panel will not be an approved product.
Does glass block count as opening protection?
Not automatically. Glass block is a glazed opening, and Florida's mitigation form gives it its own column in the glazed-openings chart. To count as protected, the glass block assembly must be a tested, approved product that meets the impact standards, or be covered by an approved shutter.
- In the HVHZ, FBC 1626.1 lists glass block among the envelope parts that must meet impact criteria, and Miami-Dade's Product Control Section approves glass block (it appears as a subcategory in the county's Product Control Search).
- Outside the HVHZ, glass block in the wind-borne debris region must be impact resistant or protected like any other glazing.
- Older glass block walls in bathrooms and stairwells, common in Florida homes from the 1950s through the 1980s, usually have no documentation. An inspector may mark them N or X.
If you have unrated glass block, your options are replacement with an approved glass block system or an approved impact window, or an approved covering. Federal wildfire guidance lists glass block as acceptable fire-resistant glazing, which sometimes gets repeated as if it were a hurricane rating. It is not.
Small bathroom windows, transoms and sidelights
These are the openings most often left out of an impact window or shutter job, and they matter just as much on the mitigation form.
- No size exemption. FBC 1609.1.2 applies to glazed openings without a minimum size, and in the HVHZ 1626.1 covers all glazing. A 2 x 2 foot bathroom window is a glazed opening.
- Transoms. A transom over a door is a separate glazed unit. Door approvals often cover a transom only up to a set height; one Miami-Dade NOA we reviewed limited a transom to a maximum of 25-1/2 inches. A transom outside the approval needs its own approved unit or protection.
- Sidelights. Sidelights beside entry doors are glazed openings and must be part of the door approval or separately approved. When a door is mulled with sidelites, the lower design pressure applies to the whole assembly.
- Obscure glass. Privacy glass in bathrooms must still be laminated impact glass if the window is impact rated.
Example: a Tampa homeowner installs approved impact windows on every window and slider, but the original 1990s glass transom over the front door is left in place. The inspector marks the windows A and the transom X. The house is rated X for opening protection. Adding an approved impact transom, or an approved shutter that covers it, brings the house to A.
Do gable vents need protection?
Gable vents are not counted in question 9 of Florida's mitigation form. But they matter for two other reasons: wind-driven rain and attic pressure.
- Water. Gable end vents are openings high on the wall facing the wind. In a hurricane they can let large amounts of wind-driven rain into the attic and onto ceilings.
- FORTIFIED. The 2025 FORTIFIED Home standard from IBHS requires, for Hurricane designations, that gable end vents have removable shutters built per its Standard Detail F-GS-1 "Gable Vent Shuttering," and that the homeowner be told the shutters are temporary and must be removed once the threat passes (Sections 3.3.2 and 4.9.2). Removing them restores attic ventilation.
- Building America. The U.S. Department of Energy guide says attic vents in gable end walls are not recommended, and where they exist and cannot be permanently covered, closable shutters or temporary structural panel coverings should be available.
- Gable walls themselves. TDI notes that collapse of a gable end wall is a common failure during hurricanes and that gable ends need additional bracing. FLASH publishes guidance on gable end bracing.
Before you permanently seal a gable vent, ask a contractor or designer whether your attic still meets ventilation requirements without it. FORTIFIED applies the same caution to vented gable rake soffits (below).
Soffits and soffit vents
Soffits are the undersides of roof overhangs. Vented soffits let air into the attic. They are not counted on Florida's opening protection question, and the HVHZ impact section (FBC 1626.1) exempts soffits, soffit vents and ridge vents, as long as the designer details their size and location. But soffits are a major source of hurricane water damage.
- Hurricane Ian. FEMA's Mitigation Assessment Team observed water intrusion primarily through sliding glass doors and soffits, affecting both older and newer homes, according to a 2024 review for the Florida Building Commission.
- Product approval. FBC 1709.10 requires manufactured soffit materials to have statewide or local product approval, with the net free (vent) area in the approval. Soffit pieces must be marked at least every 4 feet with a number tying them to the manufacturer, and the packaging or pieces must show the approval holder, model and approval method (Florida FL number, Miami-Dade NOA, TDI Product Evaluation or ICC-ES).
- FORTIFIED soffit rules. For Hurricane designations on new homes, vinyl or aluminum soffits are limited to 12 inches between support members, and aluminum soffit covers may not be used within 3,000 feet of the coast. On existing homes, soffits must be in good condition (not brittle, cracked, torn or damaged) and installed per the manufacturer's high-wind details.
- Vented gable rake soffits. FORTIFIED does not permit vented gable end rake soffits for Hurricane designations. If they are not needed for ventilation, they must be blocked, either by replacing the vented material with non-porous soffit or by plugging the gaps from inside with metal flashing and sealant.
Ridge vents, roof vents and roof turbines
Roof vents are not on Florida's opening protection question, but they are part of the roof's wind and water performance.
- TDI says skylights, roof vents and roof turbines are vulnerable to high winds and hail and that you should choose products with a published wind resistance rating. TDI has skylight, roof vent and roof turbine product listings for many manufacturers, available online or by calling 800-248-6032.
- In the HVHZ, ridge vents are exempt from the impact tests (FBC 1626.1) but still part of the roof system approval.
- Turbine heads that blow off leave an open hole in the roof. Some owners cap turbines before a storm; check the manufacturer's instructions and your roofer's advice.
These items belong to the roof, so they are usually handled in a re-roof permit. The roof is a bigger insurance factor than any opening: IBHS cites claims data showing up to 90% of hurricane-related claims include roof-related damage.
Do dryer vents, bath fans and other wall penetrations matter?
Small wall penetrations, such as dryer vents, bathroom and kitchen exhaust hoods, and HVAC lines, are not counted on Florida's opening protection question, and the HVHZ section exempts wall and roof openings for wall- or roof-mounted HVAC equipment from impact testing. They still matter for water:
- Make sure exterior hoods have working dampers or flaps that close when the fan is off.
- Seal around the penetration where it passes through stucco or siding.
- Replace cracked plastic hoods, which can break off and leave an open hole.
- Through-wall air conditioners and wall sleeves are larger openings; follow the manufacturer's storm instructions and the code's wall opening details.
None of these will change your mitigation rating, but they are cheap fixes that reduce interior water damage.
Do attic louvers and wall louvers need hurricane covers?
The Florida Building Code treats louvers in walls as openings with their own rules:
- Outside the HVHZ (FBC 1609.1.2.1): louvers protecting an exterior wall opening within 30 feet of grade must meet AMCA 540 (the louver impact standard) or be protected by an impact-resistant cover that meets the large missile test of ASTM E1996 or another approved standard. Louvers that must stay open for life safety, such as providing breathable air, must meet AMCA 540.
- In the HVHZ (FBC 1626.5): louvers within 30 feet of grade must meet AMCA 540 or the TAS 201 large missile test, or be protected by a cover meeting TAS 201, 202 and 203. All louvers, open or closed, at any height, must also pass TAS 202 pressure testing and either TAS 203 cyclic loading or AMCA 540 impact and cyclic testing.
- Garage vents: in the HVHZ, vents in a garage for four or fewer cars are exempt from the impact tests, but their size must be detailed by the designer and not exceed the minimum required area by more than 25%.
Attic louvers in gable walls are treated like gable vents for FORTIFIED purposes (removable shutters for Hurricane designation).
Jalousie windows
Jalousie windows (rows of glass or metal slats that tilt open) are common in older Florida homes and Florida rooms. FEMA's 2018 recovery advisory notes that jalousies are very susceptible to wind-driven rain even when undamaged, that panels mounted inside them are typically ineffective at stopping rain, and that common metal louvers can be breached by debris common in strong hurricanes. Under the model codes FEMA cites, metal jalousies are not required to be debris resistant, but glass jalousies are required to be debris resistant or protected by a shutter.
On Florida's mitigation form, glass jalousies are glazed openings. Unless they are approved impact products (rare) or covered by an approved shutter, they will make the house X. Many owners replace them with fixed or operable impact windows, which FEMA notes are more resistant to wind-driven rain, especially fixed units.
Do pet doors and doggie doors count as openings?
Pet doors in walls are a gray area on Florida's mitigation form, which lists windows, doors, sliders, skylights and garage doors. The clearest written rule comes from the 2025 FORTIFIED Home standard, which many insurers use for FORTIFIED discounts:
- Dog doors up to 3 square feet installed in exterior walls are exempt from impact-rating requirements.
- Dog doors located in impact-rated window and door assemblies must either be included in the tested assembly or the entire opening must be protected by an impact-rated opening protection system.
So a small pet door through a wall is generally acceptable under FORTIFIED, but cutting one into an impact door or slider panel breaks that product's rating unless the combination was tested. Pet door inserts placed in a slider track also create a gap in the slider's seal. See impact doors.
Sunrooms, screen rooms and enclosed porches
The code has specific exceptions here:
- Outside the HVHZ (FBC 1609.1.2), openings in sunrooms, balconies or enclosed porches built under existing roofs or decks need not be protected if the space is separated from the building interior by a wall whose openings are all protected. FBC Existing Building 707.5 has the same rule for existing homes.
- In the HVHZ (FBC 1626.1), roofs of screen rooms, porches and canopies that do not breach the exterior wall and have only screen sides are exempt, and exterior balconies or porches under existing roofs enclosed with screen or removable vinyl and acrylic panels meeting Section 1622 need no protection; the wall between the unit and the balcony or porch need not be protected unless another rule requires it.
The practical result: if your Florida room has unrated windows, you can either protect them or make sure every opening in the wall and door between the Florida room and the house is protected. For insurance, ask your inspector how they will treat the space before you spend money; the form counts openings in the structure's walls.
Other exemptions: high glass and small sheds
- High glazing outside the HVHZ. Glazing in Risk Category II, III or IV buildings more than 60 feet above the ground and more than 30 feet above any aggregate-surface roof within 1,500 feet may be unprotected (FBC 1609.1.2). This mostly affects high-rise condos. It does not apply in the HVHZ, where glass above 30 feet must pass the small missile test.
- Sheds. Storage sheds not designed for human habitation with a floor area of 720 square feet or less are exempt from the mandatory debris impact standards (FBC 1609.1.2 and 1626.1).
- HVHZ special buildings. Buildings for marinas, cabanas, pools and greenhouses are exempt from the HVHZ impact section.
Texas: which openings need certification on the coast?
In the Texas Department of Insurance catastrophe area (Aransas, Brazoria, Calhoun, Cameron, Chambers, Galveston, Jefferson, Kenedy, Kleberg, Matagorda, Nueces, Refugio, San Patricio and Willacy counties, plus parts of Harris County east of State Highway 146), windows, entry doors and garage doors are on TWIA's list of improvements that need a windstorm Certificate of Compliance. Since April 1, 2026, certification uses the 2024 IRC or IBC, and TDI says most of the catastrophe areas are now in the wind-borne debris region.
- Skylights: TDI says skylights are extremely vulnerable to wind-borne debris and hail and should be tested to ASTM E1886 and E1996 or other approved standards. TDI keeps skylight, roof vent and turbine product listings.
- All openings for the TWIA retrofit credit: TDI says you can install debris-resistant products a few openings at a time, but each installation needs an inspection, and an engineer files a WPI-2-BC form each time, checking a box on the final one to tell TDI all openings are protected. The retrofit credit depends on that "all openings" box, so a skipped transom or skylight matters in Texas too.
- Not needing inspection: TDI lists replacing glass in windows or doors, decorative shutters and screen doors among projects that do not require a windstorm inspection.
- Gable ends: TDI recommends additional bracing for gable ends.
See TWIA windstorm certification and TWIA coverage and opening protection.
Condos, apartments and commercial buildings
Larger buildings have more of these openings, and different paperwork:
- Different forms. Citizens Property Insurance uses OIR-B1-1802 for single-family homes, one-to-four unit dwellings and one-to-three story residential buildings. It requires the MIT-BT II and III form for condo unit owners or commercial residential applicants in buildings of four or more stories, and the WPD-1C form for commercial nonresidential opening protection.
- Roof hatches and rooftop equipment. In the HVHZ, roof hatches for personnel access and wall or roof openings for HVAC equipment are exempt from impact testing (FBC 1626.1).
- Storefront transoms and clerestories. These are part of storefront or window wall systems, whose approvals typically say the lowest design pressure of any component controls the whole system.
- Condo specifications. Florida condo boards must adopt hurricane protection specifications under Florida Statutes 718.113(5). Skylights and glass block in units usually fall under the association's control of the exterior, so check the declaration before replacing them.
- Threshold buildings. Since January 26, 2026, window and door installations in Florida threshold buildings (more than three stories or 50 feet) require a threshold inspection by a state-certified Special Inspector.
See commercial building hurricane protection and Citizens and opening protection.
Turning an N or X into an A: fixing the forgotten openings
If your last mitigation report came back N or X even though you have impact windows, the fix is usually one of these:
| Inspection finding | Likely cause | Fix |
|---|---|---|
| X with impact windows | An unprotected skylight, transom, sidelight, glass block or bathroom window | Replace with an approved impact unit or add an approved covering, then reinspect |
| N on skylights or glass block | Products may be rated, but no label or approval was found | Find the approval in the Florida or Miami-Dade database or from the installer; give the inspector the paperwork |
| N on shutters | Shutters present but undocumented, or panels not shown to the inspector | Find labels and approvals; Citizens asks that stored panels be made available |
| Z | A cracked skylight, broken glass block or damaged frame | Repair or replace; Z disqualifies the home from all mitigation rate differentials |
| A.3 instead of A.1 | A solid entry or garage door that is unrated or undocumented | Document its pressure rating (Level D gives A.2) or replace with an impact-rated door |
After the fix, schedule a new inspection; the signer must personally inspect the home, except that licensed contractors and engineers may use a qualified direct employee (Florida Statutes 627.711(3)). Citizens reserves the right to verify forms with an independent inspection. See insurance discounts.
Budgeting for the small openings
Small openings cost more per square foot to protect than big ones, because each still needs a frame, glass, anchors, labor and paperwork. We found no reliable published price for impact skylights or glass block in Florida or Texas, so get quotes. Some reference points:
- Fixr's 2025 guide prices shutters for a 24 x 42 inch window at $70 to $140 for storm panels, $85 to $200 for fabric and $100 to $200 for accordion, installed. Small windows are often cheapest to shutter rather than replace.
- Unincorporated Miami-Dade's October 2026 fee schedule adds a skylight shop drawing review fee of $92.34 for the first five skylights and $20.52 for each additional one.
- My Safe Florida Home grants can include skylights, windows and doors when the program's inspection recommends them, and DFS may require all openings to be improved for reimbursement. That makes the forgotten openings part of the grant scope, not an afterthought.
Ask every installer to quote the small openings as separate line items, so you can see the cost and decide whether to replace or shutter each one. See impact window costs and shutter costs.
Wind-driven rain: why protected openings can still leak
Impact ratings are about debris and pressure, not water. Water resistance is tested separately and at much lower pressures. Under Florida's TAS 202 and the national fenestration standard, water is tested at about 15% of the positive design pressure (20% for the heaviest commercial class), and a November 2024 review prepared for the Florida Building Commission found these protocols may not adequately assess rain intrusion in real hurricanes.
That review also summarized wind tunnel research at Florida International University's Wall of Wind facility:
- Water intrusion was observed at all wind speeds and in all double-hung window configurations tested (non-impact, impact, and shuttered non-impact), with significant intrusion between the window frames at the sill.
- An accordion shutter over a non-impact window reduced the pressure difference by about 6% to 14% and cut water intrusion by 77% to 87%.
- On a sliding glass door, shutters cut net pressure by 34% and water intrusion by 75%.
FEMA's older guidance says shutters should not be relied on to stop wind-driven rain. Read together, the message is that a shutter helps with water but does not make a leaky opening watertight. For the forgotten openings, that means: flash skylights properly at the curb, keep soffits intact, cover gable vents, and maintain weatherstripping on doors. See impact sliding glass doors for more on water ratings.
Storm-day checklist for the small openings
- Close and lock every window, including bathroom and closet windows; locked sashes seal better.
- Deploy shutters on any opening without impact glass, including transoms and sidelights if your system covers them.
- Install removable gable vent covers if you have them, and note that they must come off after the storm to restore attic ventilation.
- Check skylights from inside for cracks or leaks; you cannot shutter them, so move valuables out from under them.
- Make sure dryer and exhaust vent flaps close.
- Lock the garage door if it is manually operated and its approval requires a lock, and deploy any approved bracing or covering.
- Remove pet door inserts from sliders and close the slider fully.
- Keep one exit usable; do not shutter every door from the outside.
- After the storm, inspect every opening and photograph any damage for your insurer before repairs. Damaged openings rate Z on the next mitigation form until fixed.
Walk-around worksheet: find every opening before you buy
Before you get quotes, walk the house inside and out and fill in a list like this one. Give a copy to every installer so all quotes cover the same openings.
| Opening | Where to look | Counted on FL form Q9? | What it needs |
|---|---|---|---|
| Windows, all sizes | Every room, including bathrooms, closets and stairwells | Yes (glazed) | Impact unit or approved shutter |
| Transoms and sidelights | Over and beside entry and patio doors | Yes (glazed) | Part of an approval or separately approved |
| Sliding and French doors | Patios, balconies | Yes (glazed) | Impact unit or approved shutter |
| Entry doors | Front, side, garage-to-house exterior doors | Yes (glazed or non-glazed) | Impact or pressure-rated door |
| Garage doors | Every bay | Yes | Pressure rated; impact rated or covered if glazed (and in HVHZ) |
| Skylights and tubular skylights | Roof, from inside ceilings | Yes (glazed) | Impact-rated unit |
| Glass block | Bathrooms, showers, stairwells | Yes (glazed) | Approved assembly or covering |
| Jalousies | Florida rooms, older homes | Yes (glazed) | Replace or approved shutter |
| Gable vents and attic louvers | Gable walls | No | Removable covers (FORTIFIED); bracing check |
| Soffits | Under eaves and rakes | No | Good condition, approved product, rake vents blocked (FORTIFIED) |
| Roof vents, turbines, ridge vents | Roof | No | Wind-rated products |
| Dryer and exhaust vents | Walls | No | Working dampers, sealed |
| Pet doors | Walls, doors, slider inserts | Doors and sliders yes | Tested with the door, or wall unit up to 3 sq ft (FORTIFIED) |
Paperwork: proving every opening is protected
Florida's form requires at least one photo or document for each attribute. For the openings people forget, the paperwork is often harder than the product.
- Keep the Florida approval or Miami-Dade NOA for every skylight, transom, sidelight and glass block product, not just the windows.
- Photograph skylight labels during installation, before the interior finish covers them.
- Citizens Property Insurance recommends giving inspectors NOA letters so features that are not clearly marked still earn discounts, and asks policyholders to make stored shutters and attic access available.
- Citizens says a mitigation form is usually valid for up to five years unless improvements or structural changes call for a new one, and that new features may require documentation and a new inspection before new discounts apply.
- Knowingly providing a false mitigation form to obtain a discount is a first-degree misdemeanor under Florida Statutes 627.711(8), as quoted on the form.
See how to look up a Miami-Dade NOA and the Florida product approval lookup.
How to choose a provider
- List every opening, including bathroom windows, transoms, sidelights, skylights, tubular skylights and glass block.
- Give the same opening list to every installer so quotes are comparable.
- Confirm each skylight's approval shows impact testing (ASTM E1886 and E1996) and its missile weight.
- Replace skylights during re-roofing when possible.
- Check door approvals cover your transom and sidelight sizes; protect or replace any that are not covered.
- Treat old glass block and jalousies as unprotected unless you have approval paperwork.
- Make removable covers for gable end vents if you are pursuing FORTIFIED, and remove them after the storm.
- Check soffits for damage and confirm any replacement soffit has product approval.
- Do not cut a pet door into an impact door or slider unless the combination is approved.
- Photograph labels and keep approvals for every product for your mitigation inspection.
- In Texas coastal counties, make sure the engineer's final WPI-2-BC confirms all openings are protected.
Related hurricane shutters and impact windows guides
- Wind Mitigation Form OIR-B1-1802: How Is Opening Protection Graded (Classes A, B, C, N, X)?
- What Are Impact Windows and How Do They Survive a Hurricane? Laminated Glass, Frames and Ratings Explained
- What Is a Hurricane-Rated Garage Door? Wind Load vs. Impact Ratings, Bracing Kits and How to Read the Label
- Impact Entry Doors and French Doors: What Are the Ratings, Costs and Rules, and What Should You Look For?
- IBHS FORTIFIED Home and Opening Protection: What Silver and Gold Require for Windows, Doors and Garage Doors in Florida and Texas
- Florida Building Code Opening Protection Rules: When Is Impact Protection Required?
- Does My Safe Florida Home Pay for Impact Windows and Doors? 2026 Eligibility, Match and Status
- Do You Need a Texas Windstorm Certificate (WPI-8) for New Windows, Doors or Shutters?
Hurricane shutters and impact windows by state and city
Questions people ask
Do I need to protect a small bathroom window?
Yes, if the house is in Florida's wind-borne debris region or the HVHZ, and for insurance anywhere. The code applies to glazed openings without a minimum size, and Florida's mitigation form rates the house by its weakest glazed opening. One unprotected bathroom window can drop the whole house from Level A to X, so include every small window in your impact window or shutter plan.
Does the wind mitigation form count skylights?
Yes. Question 9 of Florida's 2026 form includes skylights in the openings it rates, with their own column. Level A for skylights requires cyclic pressure and a 4.5-pound large missile under ASTM E1886 and E1996; Level B uses a lighter missile. An untested skylight is rated X, which sets the whole house's opening protection answer to X.
Are gable vents counted on the wind mitigation form?
No. The 2026 form says gable roof vents and other roof vents are not included in the opening protection question. They still matter for wind-driven rain, which is why the FORTIFIED Home standard requires removable gable vent shutters for its Hurricane designations, and why the U.S. Department of Energy's Building America guide recommends against gable end vents.
Can I put a shutter over my skylight?
Generally no practical approved option exists. The U.S. Department of Energy's Building America guide states that opening protection for skylights is not available, so skylights should be impact and pressure rated. FLASH says covering skylights before a hurricane is inconvenient. The usual fix is to replace the skylight with an impact-rated unit, ideally during re-roofing.
Is glass block hurricane-proof?
Not automatically. Glass block is a glazed opening on Florida's mitigation form and must be an approved, tested product or be covered to count as protected. In the HVHZ, the code lists glass block among the envelope parts that must meet impact criteria, and Miami-Dade approves glass block systems. Older undocumented glass block is often rated N or X.
Do soffit vents need hurricane protection?
They are not counted on Florida's opening protection question and are exempt from HVHZ impact tests, but they are a major source of storm water intrusion. FEMA observed water intrusion primarily through sliders and soffits after Hurricane Ian. Keep soffits in good repair, use approved soffit products, and, for FORTIFIED, block vented gable rake soffits that are not needed for ventilation.
Do transom and sidelight windows need impact glass?
Yes, if the house is in Florida's wind-borne debris region or the HVHZ, or if you want Level A on the mitigation form. Transoms and sidelights are glazed openings. They must be part of the door's approval or separately approved. Door approvals often limit transom size, and when a door is mulled with sidelites, the lower design pressure applies to the whole assembly.
Will the inspector check my attic louvers and dryer vents?
Not for the opening protection question. Florida's 2026 form excludes gable and other roof vents from question 9, and small wall penetrations are not listed. The inspector will look in the attic for roof deck attachment and roof-to-wall connections, so Citizens asks that attic access be available. Vents still matter for water intrusion, so keep dampers working and seals intact.
Do I have to protect windows in my Florida room?
Not if the Florida room is under an existing roof and separated from the house by a wall whose openings are all protected (FBC 1609.1.2 and Existing Building 707.5). In the HVHZ, screened or removable-panel enclosures meeting Section 1622 have a similar exception. Ask your mitigation inspector how they will treat the room before deciding which openings to protect.
Do jalousie windows count against my wind mitigation rating?
Glass jalousies are glazed openings, so on Florida's mitigation form they are rated like any other window. Unless they are approved impact products or covered by an approved shutter, they will be marked X and set the whole house to X. FEMA also notes jalousies let in wind-driven rain even when undamaged. Replacing them with fixed or operable impact windows is the common fix.
Are pet doors in walls a problem for FORTIFIED?
Not if they are small. The 2025 FORTIFIED Home standard exempts dog doors up to 3 square feet installed in exterior walls from impact-rating requirements. A dog door cut into an impact-rated door or window assembly is different: it must be part of the tested assembly, or the entire opening must be covered by an impact-rated protection system.
Does a skylight need a permit to replace?
In most Florida jurisdictions, yes, because it is part of the roof and the building envelope. FBC Existing Building 707.4 requires replacement skylights to comply with Chapter 16. Unincorporated Miami-Dade also charges a skylight shop drawing review fee of $92.34 for the first five skylights. In Texas coastal counties, check with TDI whether your skylight work needs a windstorm inspection.
Sources
- Florida OIR Form OIR-B1-1802, Uniform Mitigation Verification Inspection Form, Rev. 04/26
- Florida Building Code, Building, 8th Ed. (2023), Chapter 16 (UpCodes)
- Florida Building Code, Building, 8th Ed. (2023), Chapter 17 (UpCodes)
- Florida Building Code, Residential, 8th Ed. (2023), Chapter 3 (UpCodes)
- Florida Building Code, Existing Building, 8th Ed. (2023), Chapter 7 (UpCodes)
- U.S. DOE Building America Solution Center: Windows have impact-rated glass or protective coverings
- FLASH: Install impact-resistant skylights
- IBHS: 2025 FORTIFIED Home Standard
- IBHS FORTIFIED: Before the Storm, a homeowner's guide to hurricane readiness
- FEMA Recovery Advisory USVI-RA4 (March 2018): Design, Installation, and Retrofit of Doors, Windows, and Shutters
- Florida Building Commission / FIU: Wind-Driven Rain Intrusion through Tracks of Sliding Glass Doors (Nov. 2024)
- Miami-Dade County: Product Control Search
- Miami-Dade County: Product Approval
- Miami-Dade NOA 25-0317.01 (sample door with transom limit)
- Miami-Dade County Implementing Order 4-63, Fee Schedule (effective Oct. 1, 2026)
- Florida Statutes 215.5586, My Safe Florida Home Program
- My Safe Florida Home
- Citizens Property Insurance: Your Wind Inspection
- Citizens Property Insurance: Wind Inspection Results
- Citizens Property Insurance: Updating Mitigation Features
- Florida Building Code, Building, 8th Ed. (2023), Chapter 2 Definitions (UpCodes)
- Florida Statutes 627.711, Notice of premium discounts for hurricane loss mitigation
- Florida Statutes 718.113 (condominium hurricane protection)
- Miami-Dade County: Windows, Shutters, Doors and Security Bars
- Fixr: Hurricane Shutters Cost (updated Jan. 31, 2025)
- Texas Department of Insurance: Windstorm FAQ for building
- Texas Department of Insurance: Making repairs after a storm
- Texas Department of Insurance: Windstorm general questions
- Texas Department of Insurance: Adopted Building Codes
- Texas Department of Insurance: Do you need a windstorm inspection?
- TWIA: Windstorm Certification