Florida Product Approval is the state listing, required by Fla. Stat. 553.842, that shows a window, door, shutter or skylight met the Florida Building Code. To check one, go to floridabuilding.org, choose Product Approval, then Find a Product or Application, pick the code version and enter the FL number (##### or #####.#). Confirm the status is Approved, the model matches your quote, impact resistance and HVHZ approval fit your home, and the design pressures meet your openings.

Key facts

  • Fla. Stat. 553.842(5) requires statewide approval for panel walls, exterior doors, roofing, skylights, windows, shutters, impact protective systems and structural components (leg.state.fl.us).
  • Marketing a product as hurricane, windstorm or wind-borne debris protection without approval under s. 553.842 or 553.8425 is subject to Florida's Deceptive and Unfair Trade Practices Act.
  • The floridabuilding.org search accepts FL numbers as ##### for an application or #####.# for a product.
  • Rule 61G20-3.012: a revision keeps the original FL number plus R1, R2 and supersedes the original once approved.
  • There are four statewide compliance methods: certification mark or listing, test report, evaluation entity report, or sealed Florida engineer or architect report.
  • Statewide approval bars local jurisdictions from requiring further testing when a product is used consistent with its approval (s. 553.842(4)).
  • Code changes do not void approvals of products already installed if they met the code when installed (s. 553.8425(7)).
  • DBPR: the 9th Edition (2026) Florida Building Code takes effect December 31, 2026; product approval fees were waived July 1 to December 31, 2026.
  • Miami-Dade accepts Florida Building Commission approvals as well as NOAs for window, door and garage door permits.

What is Florida Product Approval?

Florida Product Approval is the state system that decides which building envelope products may be used under the Florida Building Code. It covers the parts of a building that keep wind and water out and hold the structure together. Section 553.842 of the Florida Statutes orders the Florida Building Commission to run "a product evaluation and approval system that applies statewide." The Commission's detailed rules are in Florida Administrative Code Chapter 61G20-3.

The law names eight product categories that must be approved through one of the state's set methods: panel walls, exterior doors, roofing, skylights, windows, shutters, impact protective systems and structural components. If you are buying impact windows, a hurricane shutter, an impact entry door, a sliding glass door, a skylight or a wind-rated garage door in Florida, the product falls into this system.

Approval is not a seal of quality or a ranking. It means a product was tested or evaluated against the code standards that apply to it, that the paperwork was checked by an independent party, and that the maker runs a quality assurance program. The approval also sets limits: the sizes, design pressures, anchors and installation methods the product was proven with. Use it outside those limits and it is no longer an approved installation.

Why the law matters to a homeowner

Section 553.842(5) has a consumer rule that many people never hear about. A product "may not be advertised, sold, offered, provided, distributed, or marketed as hurricane, windstorm, or impact protection from wind-borne debris" unless it is approved under s. 553.842 or s. 553.8425. Anyone who markets an unapproved product that way is subject to Florida's Deceptive and Unfair Trade Practices Act. So if a seller calls a product "hurricane rated," you have a legal right to expect an approval behind that claim, and you can check it yourself in a few minutes.

What is the Florida Building Commission?

The Florida Building Commission is the state body that adopts and updates the Florida Building Code and oversees product approval. Day to day, the program is run by the Department of Business and Professional Regulation (DBPR), Codes and Standards section, through the Building Code Information System (BCIS) at floridabuilding.org. The product approval office lists its address as 2601 Blair Stone Road, Tallahassee, FL 32399, phone 850-487-1824.

Under s. 553.842(5)(a), applications based on a certification listing or an evaluation entity report are approved by DBPR after staff verify that the file is complete, which the statute says must happen within 10 business days. The Commission's program oversight committee then ratifies those approvals. Applications based on a test report or an engineer's or architect's evaluation go to the Commission. DBPR's June 30, 2026 training presentation describes the review as about two months for test reports and engineer or architect evaluations, and ten days for certification and evaluation entity files.

What is an FL number and how do I read it?

An FL number is the identifier the state assigns to a product approval in BCIS. The search page itself explains the format: an application number looks like ##### and a product inside that application looks like #####.#. One application often covers several related products, so FL12345.1 and FL12345.2 (illustrative numbers) would be two products filed under the same application.

Revision suffixes (R1, R2 and so on)

Rule 61G20-3.012 explains what happens when a manufacturer changes an approval. The revision "will carry the same Florida Product Approval number as the original approval with the addition of a revision number assigned, R1, R2, as applicable." The rule adds that once the Commission approves a revision, "the approved revision will supersede the original approval." In practice you will see numbers written with an R suffix, for example FL12345-R3 (illustrative). The base number stays the same; the suffix tells you which version you are looking at.

This matters when you compare paperwork. If your contractor hands you a printout for FL12345-R2 and the database shows FL12345-R4 as current, ask what changed. Revisions can add sizes, change glass options, change anchors, or update the approval to a new code edition. The installation must follow the version used on the permit, and the inspector will check that version.

Code version is part of the identity

Every approval is tied to a Florida Building Code edition. The search page lists code versions 2001, 2004, 2007, 2010, 2014, 2017, 2020, 2023 and a new "Pre-2026" choice. Under s. 553.842(1)(f), approvals stay valid until the code requirements they rest on change, the product changes in a way that affects performance, or the approval is revoked. That is why a product approved under the 2020 code may need a new approval or an affirmation to be used under the 2023 code or the 2026 code.

What you seeWhat it means
FL12345Application number (one filing by a manufacturer)
FL12345.1Product 1 within that application
FL12345-R2Second revision of the application; supersedes earlier versions once approved
Code Version 2023Approval is for the 8th Edition (2023) Florida Building Code
Code Version Pre-2026Filing made for the 9th Edition (2026) code before it takes effect

The FL numbers above are made-up examples to show the format. Always search the real number on floridabuilding.org.

How do I search a product on floridabuilding.org? (Step by step)

The public search is free and needs no login. Here is the path as it appeared when we checked it on November 19, 2026.

  1. Open the Product Approval menu. Go to floridabuilding.org and choose Product Approval, or go straight to floridabuilding.org/pr/pr_default.aspx. You will be shown as "Public User."
  2. Click "Find a Product or Application." This opens the search page at floridabuilding.org/pr/pr_app_srch.aspx. The page says: "You can search for products by FL number or by any search criteria," and "Each criteria selected narrows the scope of your search."
  3. Pick the code version. The page tells users: "If you have the FL#, enter the FL# and the appropriate code version of the application and click search." For work permitted today, the current code is the 8th Edition (2023), which the page notes "became effective December 31, 2023." If your permit will be reviewed under the 9th Edition (2026), look at "Pre-2026" approvals too.
  4. Enter the FL number without the letters "FL" in the box marked FL #, in the format the page shows (##### for an application or #####.# for a product).
  5. Or search by criteria. If you do not have the number, choose the Product Manufacturer from the long list, then narrow by Category (Windows, Shutters, Exterior Doors, Skylights, Impact Protective Systems and others), Subcategory, and Application Status.
  6. Use the wind filters. The form has "Approved for use in HVHZ" (Yes or No), "Approved for use outside HVHZ" (Yes or No), "Impact Resistant" (Yes, No or N/A) and a Design Pressure field (a plus or minus value). These help you find only products that fit your home.
  7. Click Search and open the matching application to read its details and attached documents.
  8. Check the status. The status list includes Approved, Validated, Pending FBC Approval, Applied For, Re-Apply, Denied, Suspended and Revoked. Only an approved status means the product is listed for use.

What to compare against your quote or permit

  • The manufacturer name and the product model, series or name on your quote.
  • Whether the product is impact resistant, if your home needs impact protection.
  • Whether it is approved for the HVHZ if you live in Miami-Dade or Broward County.
  • The positive and negative design pressures, compared with what your openings require.
  • Size limits. FBC 1709.5.1 lets sizes other than the tested size carry different pressures only when set by accepted engineering analysis, with strict limits.
  • The installation instructions and anchor schedule for your wall type (wood frame, concrete block or poured concrete).
  • The code version and the current revision number.

If a search turns up nothing, check the spelling of the manufacturer, remove filters one at a time, and confirm the product is not instead listed only with Miami-Dade County. Miami-Dade runs its own Notice of Acceptance (NOA) search, covered in our Miami-Dade NOA lookup guide.

What are the four compliance methods (evaluation method)?

When you open an approval, one field tells you how the product proved it meets the code. The search page calls this the Compliance Method. Section 553.842(5)(a) lists the four methods for products the code has standard tests for:

Compliance method (as named on the search page)What it is under s. 553.842(5)(a)Who approves
Certification Mark or ListingA mark or listing from an approved certification agency, used only where the code designates standardized testingDBPR
Test ReportA test report from an approved testing laboratoryFlorida Building Commission
Evaluation Report from a Product Evaluation EntityA report based on testing, comparative or rational analysis from an approved evaluation entityDBPR
Evaluation Report from a Florida Registered Architect or Licensed Florida Professional EngineerA signed and sealed evaluation report by a Florida-licensed engineer or architectFlorida Building Commission

The "who approves" column comes from DBPR's 2026 training slides on the four methods for state approval. For products with no standard test in the code, s. 553.842(5)(b) allows approval only by an evaluation entity report or a sealed engineer or architect report.

Who are the evaluation entities?

The statute tells the Commission to approve several evaluation entities by name: the National Evaluation Service, the IAPMO Evaluation Service, ICC Evaluation Services, Underwriters Laboratories, Intertek Testing Services NA, and the Miami-Dade County Building Code Compliance Office Product Control Division. Florida-licensed architects and engineers may also do evaluations. Every entity, engineer and architect involved must meet a recognized standard showing independence from the manufacturer.

Testing labs, quality assurance and validation

  • Testing labs must be accredited by national bodies such as A2LA or the National Voluntary Laboratory Accreditation Program, or by an approved evaluation entity, under s. 553.842(8)(b).
  • Quality assurance: manufacturers with a state approval must run a quality assurance program for every approved product, under s. 553.842(6). The search page lets you filter by Quality Assurance Entity and shows when a QA contract has expired.
  • Validation: state approvals are checked by independent validation entities that certify the product's compliance to the Commission, under s. 553.842(7).

For a homeowner, the method matters less than the result. All four methods lead to the same approved listing. But knowing the method tells you where to find the proof: a test report method means the lab report is the backbone; an evaluation method means the evaluation report holds the design pressures, limits and installation details.

What does 'approved for use in HVHZ' mean?

HVHZ stands for High-Velocity Hurricane Zone. Florida's mitigation form and the Florida Building Code treat Miami-Dade and Broward counties as the HVHZ. These two counties have their own, stricter sections of the code (Sections 1612 through 1626 of the FBC Building, plus TAS test protocols). For example, the FBC sets HVHZ design wind speeds for Risk Category II buildings at 175 mph in Miami-Dade and 170 mph in Broward.

The state search form has two separate yes or no fields: "Approved for use in HVHZ" and "Approved for use outside HVHZ." A product can be approved for one and not the other. Many products are approved statewide outside the HVHZ but were never tested to the HVHZ protocols. If you live in Miami, Fort Lauderdale, Hollywood, Homestead or anywhere else in those two counties, the approval must say yes for the HVHZ, or the product must carry a Miami-Dade NOA.

HVHZ approvals and Miami-Dade NOAs

Miami-Dade County's Product Control Section reviews building envelope products, mainly windows, exterior glazing, wall cladding, roofing, exterior doors, skylights, glass block, siding and shutters. Test labs used for its approvals must be Miami-Dade certified. Miami-Dade's own permit pages say Florida Building Commission product approvals are acceptable for window, door and garage door permits, alongside NOAs. So in Miami-Dade you can use either an NOA or a state approval that covers the HVHZ.

Miami-Dade publishes its fees for manufacturers: $4,000 for a first-time approval valid five years, $1,500 for a revision and $1,500 for a five-year renewal, all plus a 7.5% surcharge. Those are costs to the manufacturer, not to you, but they explain why some products carry only a state approval.

See our HVHZ requirements guide for the full set of HVHZ rules.

Statewide approval vs. local approval: what is the difference?

Florida has two paths for proving a product meets the code. Statewide approval is the listing in BCIS described above. Local approval happens permit by permit, under s. 553.8425, when a local building official accepts a product for a specific job.

FeatureStatewide approval (s. 553.842)Local approval (s. 553.8425)
Where it is recordedPublic list on floridabuilding.orgThe local permit file
Who decidesDBPR or the Florida Building CommissionThe local building official or authority having jurisdiction
Ways to prove complianceFour methods in s. 553.842(5)Six methods, including a certification mark, test report, evaluation entity report, sealed engineer or architect report, a statewide approval, or a prescriptive material standard adopted by rule
Can the city ask for more testing?No. Statewide approval "shall preclude local jurisdictions from requiring further testing, evaluation, or submission of other evidence" if the product is used within its approvalThe official reviews the evidence for that project
Quality assuranceRequired for all approved productsProducts must be made under a QA program audited by an approved QA entity
Best forMost mass-produced windows, doors and shuttersUnusual, custom or one-off situations

Two points protect you as the owner. First, under s. 553.842(4), a local jurisdiction cannot demand extra tests for a product with statewide approval that is used consistent with its approval. Second, s. 553.8425(7) says "Changes to the code do not void the approval of products previously installed in existing buildings if such products met building code requirements at the time the product was installed." A shutter legally installed in 2015 does not become illegal because the code changed.

Can a building official still reject an approved product?

Yes, in one situation. Under s. 553.842(9), a building official may deny local use of a statewide approved product if the official writes and signs a report concluding that the particular application is inconsistent with the approval and gives the reasons. That decision can be appealed to the local board of appeals, if there is one, and then to the Commission. The common real-world case is a product used outside its limits, such as on a larger opening or with the wrong anchors.

Custom fabricated products do not need a separate approval if their parts are approved for that use and meet the code, under s. 553.842(10).

What are the installation instructions in a product approval, and why do they matter?

The approval does not cover a product sitting in a warehouse. It covers the product installed a certain way. The Florida Building Code makes this explicit for shutters: FBC 1709.9.4 requires impact-resistant coverings to be installed per the manufacturer's instructions and the product approval, with instructions available to inspectors on the job site.

The installation drawings usually set out:

  • The anchor type, size, embedment and spacing for each wall material.
  • Edge distances in concrete or masonry.
  • Whether a wood buck (a wood frame strip around the opening) is allowed and how it is fastened.
  • Maximum opening sizes for each design pressure.
  • Glass types and thicknesses for windows (Miami-Dade calls this the glass schedule and wants your choices marked on the plans).
  • Mullion sizes and connections when two windows are joined.
  • For shutters, the separation needed between the shutter and the glass, and how panels overlap.

Under FBC 107.1.1, a homeowner replacing windows, doors or garage doors on a one- or two-family home or townhouse does not need sealed drawings from a design professional if the units are installed per the manufacturer's instructions for the wind zone, meet current design pressures, are the same size in the same opening, and a copy of the instructions is submitted with the permit application. That is one of the most practical reasons to pull the approval: the instructions become part of your permit.

Labels you can check on site

FBC 1709.5.1 requires windows and sliding doors to carry a permanent label tracing to the maker and product. A permanent or temporary supplemental label must show the manufacturer, model or series, positive and negative design pressure, maximum size tested, impact rating if any, the Florida or Miami-Dade approval number, the test standards and the certification agency or lab. The temporary label must stay on until the building official's final approval. For shutters, FBC 1709.9 requires a permanent label with the approval holder, the approval methods, test standards and the Florida approval or NOA number. On accordion shutters it goes on the bottom of the locking bar or center mate facing out. On roll-up shutters it goes on the bottom of the hood or bottom slat facing out.

Do not peel off temporary window labels before the final inspection. Take a photo of each label for your records. Those photos are also useful for a wind mitigation inspection.

How do I verify my contractor's product is approved?

Ask for the FL number or NOA number of every product in the quote before you sign. A licensed installer should have them ready because they go on the permit. Then:

  1. Search each number on floridabuilding.org with the right code version.
  2. Confirm the manufacturer and model match the quote word for word.
  3. Confirm "Impact Resistant" is Yes if you are buying impact protection.
  4. If you are in Miami-Dade or Broward, confirm HVHZ approval or a current NOA.
  5. Compare the design pressures on the approval with the required pressures for your openings. Your contractor or engineer should show you those numbers. See our design pressure guide.
  6. Check the status is Approved and note the current revision.
  7. Download or print the approval and installation instructions and keep them with your permit card.
  8. After installation, compare the labels on the units with the approval number.

Red flags

  • A seller calls a product "hurricane proof" or "impact rated" but cannot give an FL number or NOA. Under s. 553.842(5) that marketing requires an approval.
  • The approval on the paperwork belongs to a different manufacturer than the product delivered.
  • The approval is marked Suspended, Revoked, Denied or still Pending.
  • The approval is not valid for the HVHZ and you live in Miami-Dade or Broward.
  • A product sold as "Force 12" rated. The Texas Department of Insurance warns that a Force 12 rating "only meets the very minimum of a category 1 hurricane (74 mph)," which is not the same as a hurricane impact approval.

Product approval and contractor licensing are separate checks. Verify the installer's license too. Our guide to comparing quotes walks through both.

What if my product approval was revised, expired or withdrawn?

Approvals change for three main reasons under s. 553.842(1)(f): the code the approval is based on changes, the product changes in a way that affects performance, or the approval is revoked. Here is how each case affects you.

SituationEffect on a product already installed with a permitEffect on a product not yet installed
Revision approved (new R number)None. Your permit used the version current thenUse the current revision on the permit
New code edition, product not yet updatedNone. s. 553.8425(7) says code changes do not void previously installed approved productsMay not be usable on permits under the new code until affirmed or revised
Approval suspended or revokedAsk your building department how it treats permits already finaledDo not install. Pick a product with a valid approval

The 2026 code change (9th Edition)

DBPR's June 30, 2026 product approval presentation states that the 8th Edition (2023) is the current code, effective December 31, 2023, and the 9th Edition (2026) has an effective date of December 31, 2026. Starting July 1, 2026, manufacturers could file for the new code under a "Pre-2026" choice in BCIS. DBPR gives manufacturers three ways to carry a product to the new code:

  • Self-affirmation, if the standards and limits that apply to the product have not changed.
  • Revision, required if the standards or limits changed, with new evidence such as a test or evaluation report. Editorial revisions cannot be used to update to the new code.
  • New application.

DBPR also announced that application fees are waived from July 1 through December 31, 2026. If your project's permit will be reviewed after December 31, 2026, ask your contractor to confirm the products are approved under the 2026 code version, not only the 2023 version. Miami-Dade County has said that expired permit applications that do not meet its extension criteria will need new plans that conform to the 2026 FBC edition.

Do I need the FL number for a permit?

In practice, yes. Building departments check product approvals at plan review and again at inspection. Miami-Dade's checklists for window, mullion and glass door replacement, garage doors, exterior doors, skylights and shutters each require "the current Notice of Acceptance (NOA)" for every product, and say "Florida Building Commission product approvals are acceptable." For new windows, Miami-Dade also wants the required positive and negative design pressures of each unit on the plans, "typically located on your product approval documents," and the glass type and options picked from the approval's glass schedule. For shutters and storm panels, if the approval covers more than one panel or attachment method, you must mark the one being used.

Other Florida counties and cities follow the same idea even if their checklists look different. The FBC requires the approval number on the product label and requires shutters to be installed per the approval. So whether you live in Tampa, Orlando, Jacksonville or St. Petersburg, plan on giving the building department the FL numbers. Our Florida permit guide covers the full document list.

Approval numbers on the wind mitigation form

The approval matters long after the permit closes. Florida's Uniform Mitigation Verification Inspection Form (OIR-B1-1802, Rev. 04/26) only gives top credit for opening protection listed "in the product approval system of the State of Florida or Miami-Dade County." Citizens Property Insurance tells policyholders to hand inspectors Notice of Acceptance letters for products that are not clearly marked. A missing approval number is a common reason an inspector marks shutters "N" (unverified) instead of "A." See our insurance discounts guide.

Texas: is there a product approval system like Florida's?

Texas does not have a statewide product approval list for all homes. What it has is tied to windstorm insurance on the coast. In the 14 first-tier coastal counties and the listed Harris County cities east of State Highway 146, construction must be certified by the Texas Department of Insurance (TDI) for the property to be eligible for Texas Windstorm Insurance Association (TWIA) coverage.

For that program, TDI publishes product evaluation reports and posts links to third-party evaluation reports. TDI says these are used to make sure products "comply with TDI adopted building specifications" and are installed to resist wind load. It also notes that "TDI does not approve the use of or endorse any product," and that a linked third-party report does not by itself prove an improvement complies with the windstorm code. If a report is missing, TDI tells builders to contact the manufacturer for a test report.

TDI's homeowner guidance says to use only opening protection tested to ASTM E1886 and ASTM E1996 "and designated as such by a recognized product approval." Garage doors must be tested to ASTM E330, with glass panels rated to ASTM E1996. The FBC itself recognizes "TDI Product Evaluation" as one of the approval methods that can appear on a shutter label.

In Houston, Dallas, San Antonio and Austin, which are outside TDI's designated catastrophe areas, product acceptance is handled by the city building department under its adopted code. Ask the department what evidence it wants for windows and doors. See our TWIA windstorm certification guide and the Texas hub.

Florida Product Approval vs. Miami-Dade NOA vs. TDI evaluation

ItemFlorida Product ApprovalMiami-Dade NOATDI product evaluation (Texas)
Legal basisFla. Stat. 553.842; FAC 61G20-3Miami-Dade Product Control under the FBC HVHZ provisions; named as an evaluation entity in 553.842(8)(a)Texas Insurance Code ch. 2210; 28 TAC ch. 5
Where usedStatewide; HVHZ only if marked approved for HVHZAccepted in Miami-Dade and Broward; also used statewide as an evaluationTDI windstorm certification for TWIA eligibility on the coast
Search toolfloridabuilding.org, Find a Product or ApplicationMiami-Dade Product Control Search (file numbers like 01-0712.04)TDI windstorm product evaluation pages
Number formatFL#####, FL#####.#, revisions R1, R2NOA file numberReport number assigned by TDI or the third party
ValidityUntil code basis changes, product changes, or revokedFive years for a first approval, per Miami-Dade's fee pagePer TDI listing

How to choose a provider

  • Ask for the FL number or NOA of every product before you sign a contract.
  • Search each number at floridabuilding.org/pr, Find a Product or Application, using the correct code version.
  • Match manufacturer, model and series to the quote.
  • Confirm Impact Resistant is Yes if you need impact protection.
  • In Miami-Dade or Broward, confirm HVHZ approval or a current NOA.
  • Compare the approval's design pressures with the pressures required for each opening.
  • Check the status is Approved and note the current revision number.
  • Save the approval, installation instructions and anchor details with your permit papers.
  • If your permit will be reviewed after December 31, 2026, confirm a 2026-code approval.
  • Photograph every label before temporary labels are removed after final inspection.
  • Give copies to your wind mitigation inspector and insurance agent.

Related hurricane shutters and impact windows guides

Hurricane shutters and impact windows by state and city

Questions people ask

Is a Florida Product Approval the same as a Miami-Dade NOA?

No. A Florida Product Approval is the state listing on floridabuilding.org under s. 553.842. A Miami-Dade Notice of Acceptance is issued by Miami-Dade County's Product Control Section, which is also one of the evaluation entities the statute names. Miami-Dade accepts state approvals for window and door permits, and many state approvals rely on Miami-Dade evaluations. In Miami-Dade and Broward, a state approval must be marked approved for use in the HVHZ.

Can I search without an FL number?

Yes. On the Find a Product or Application page you can pick the manufacturer from a list and narrow by category, subcategory, status, compliance method, HVHZ approval, impact resistance and design pressure. Each choice narrows the results. If you know the product name or model, the Product Model, Number or Name field helps. Searching by manufacturer and category is often the fastest way to confirm a quote.

What does 'Validated' mean in the status list?

Validation is the step where an independent validation entity checks the application and certifies to the Commission that the product complies, under s. 553.842(7). A validated application has passed that check but may still be waiting for final approval. For a permit, look for an Approved status. If you only see Validated or Pending FBC Approval, ask your contractor when approval is expected or choose another product.

My shutters were installed in 2010. Are they still legal now that the code changed?

If they were properly permitted and met the code when installed, a later code change does not void them. Section 553.8425(7) says changes to the code do not void the approval of products previously installed in existing buildings if they met the code at the time. Insurance credit is a separate question: the inspector still needs proof, such as the permit, labels or the approval, to classify them on the wind mitigation form.

Where do I find the design pressure on the approval?

Open the application record and read the evaluation or test documents and installation drawings. Miami-Dade notes the required pressures are typically shown on product approval documents under a heading such as Design and Pressures Rating (psf). Values are given as a positive and a negative number in pounds per square foot and usually vary by size. The search form also lets you filter by design pressure.

Does an FL number guarantee my windows will survive a hurricane?

No. An approval shows the product passed the code tests for the conditions listed, when installed exactly as approved. Real storms can exceed design conditions, and poor installation can defeat a good product. IBHS research after Hurricane Michael found modern codes significantly improve resilience but are not meant to prevent all damage in extreme events. Correct installation, the right pressures and a final inspection matter as much as the approval.

Who do I call with a question about a state approval?

The product approval office of the Florida Building Commission is part of DBPR, 2601 Blair Stone Road, Tallahassee, FL 32399, phone 850-487-1824. DBPR's 2026 training materials list a team email, procodesproductapproval@myfloridalicense.com. For questions about whether a product fits your specific permit, call your local building department, which makes the call on each job.

Is it illegal to sell shutters as hurricane protection without approval?

Under s. 553.842(5), a product may not be advertised, sold or marketed as hurricane, windstorm or wind-borne debris impact protection unless approved under s. 553.842 or s. 553.8425. A violation is subject to Florida's Deceptive and Unfair Trade Practices Act, enforced by the enforcing authority defined in s. 501.203. If you think you were sold an unapproved product as hurricane protection, keep the ads and paperwork and ask a consumer attorney or your local consumer protection office how to file a complaint.

Do Texas homes need a Florida product approval?

No. Florida's system applies under the Florida Building Code. In Texas, coastal homes seeking TWIA eligibility need TDI windstorm certification, and TDI asks for products tested to ASTM E1886 and E1996 with a recognized product approval or evaluation. Many manufacturers carry both Florida approvals and Texas evaluations, so a Florida approval can be useful evidence, but the TDI inspector or engineer decides what is accepted.

What happens to approvals on December 31, 2026?

DBPR says the 9th Edition (2026) Florida Building Code takes effect December 31, 2026. Products need to show compliance with the new code by self-affirmation, revision or new application. Since July 1, 2026, those filings appear under the Pre-2026 code version in BCIS. Products that are not updated may not be usable on permits reviewed under the new code. Installed products are not affected.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration