How impact windows, doors and shutters are tested with 9-pound 2x4s and steel balls, what the 30-foot rule and 9,000-cycle test mean, and how Florida and Texas codes use ASTM and TAS standards.

Impact products are shot with debris and then pressure-cycled. The large missile is a 9-pound 2x4 fired at 50 feet per second (80 for essential facilities in the HVHZ); the small missile is 2-gram steel balls at 130 feet per second. Florida requires the large missile test for glazing within 30 feet of grade. ASTM E1886 is the test method and ASTM E1996 the performance specification; Miami-Dade and Broward use TAS 201, 202 and 203.

Key facts

  • HVHZ large missile: a 9-lb 2x4 at 50 ft/s, or 80 ft/s for Risk Category IV essential facilities (FBC 1626.2.3).
  • HVHZ small missile: 2-gram solid steel balls, 5/16 in diameter, at 130 ft/s, 30 impacts in groups of 10 (FBC 1626.3).
  • Each HVHZ specimen takes two large missile hits: one near the center and one 6 inches from a corner support (FBC 1626.2.5); three specimens are tested.
  • HVHZ cyclic loading: 9,000 cycles (4,500 inward, 4,500 outward), each 1 to 3 seconds, up to 0.6 times the ultimate design load (FBC Table 1626).
  • Outside the HVHZ, glazing within 30 ft of grade must pass the ASTM E1996 large missile test; above 30 ft, the small missile test (FBC 1609.1.2).
  • The 2023 FBC references ASTM E1886-13a or -19 and ASTM E1996-14a, -17 or -20.
  • FBC 1609.1.2.2 defines ASTM E1996 Wind Zones 1 to 4 by ultimate wind speed, with a one-mile coastline rule for 140 to 170 mph.
  • Florida law approves test labs accredited by organizations such as A2LA and NVLAP (s. 553.842(8)(b)); Miami-Dade requires its own lab certification.

Why impact windows and shutters are shot with lumber

In a hurricane, the wind picks up roof tiles, fence boards, branches, gravel and pieces of other houses and throws them at your walls. Once one of those pieces breaks a window, wind rushes in. IBHS explains that broken windows let in wind and rain and create internal pressures that push up on the roof and out on the walls. That is how one broken pane can lead to a lost roof.

Missile impact tests recreate that debris in a lab. A product is hit with a standard object at a standard speed, then put through thousands of pressure cycles to see if it holds together for the rest of the storm. The Florida Building Code requires these tests for every glazed opening in a windborne debris region, and Texas requires them for coastal homes seeking windstorm certification.

There are two families of test standards:

  • ASTM E1886 and ASTM E1996, the national standards used statewide in Florida outside the HVHZ and under the International Codes in Texas.
  • TAS 201, TAS 202 and TAS 203, the Florida Testing Application Standards, which the state mitigation form lists alongside Miami-Dade's matching PA 201, 202 and 203 protocols, and which are required in the High-Velocity Hurricane Zone (Miami-Dade and Broward).

What is ASTM E1886 vs. ASTM E1996?

The two ASTM standards work as a pair. One tells the lab how to run the test, the other tells everyone what result is required.

StandardWhat it isEditions referenced in the 2023 FBC
ASTM E1886Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Impact Protective Systems Impacted by Missiles and Exposed to Cyclic Pressure DifferentialsE1886-13a or E1886-19
ASTM E1996Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. Intertek's summary says it covers missile levels (size and impact speed), missile levels for wind zones, and a cyclic static air pressure loading tableE1996-14a, E1996-17 or E1996-20

Think of E1886 as the recipe and E1996 as the passing grade. A test report should name both, with editions. The Florida Department of Emergency Management's homeowner guide states that ASTM E1886 and E1996 are required for product approval in the rest of Florida (outside Miami-Dade and Broward) and under the International Building Code in windborne debris regions.

Florida's change to the ASTM wind zones

ASTM E1996 picks the required missile level based on a wind zone. Florida rewrites those zones in FBC 1609.1.2.2 so they match Florida's ultimate design wind speeds (Vult):

ASTM E1996 wind zone (as substituted by the FBC)Ultimate design wind speed
Wind Zone 1130 mph or more, but less than 140 mph
Wind Zone 2140 mph or more, but less than 150 mph, more than one mile from the coastline
Wind Zone 3150 to 170 mph, or 140 to 170 mph within one mile of the coastline
Wind Zone 4More than 170 mph

The coastline is measured from the mean high water mark. The FBC Residential (R301.2.1.2.1) makes the same substitution for homes. Higher zones call for tougher missile levels or higher cyclic pressures in the standard.

What are TAS 201, 202 and 203?

The Testing Application Standards are Florida's HVHZ protocols. FBC 1626 requires them for buildings in Miami-Dade and Broward.

ProtocolWhat it tests
TAS 201Impact test procedures: large and small missiles. Intertek describes it as a test for "determining whether a particular product provides sufficient resistance to windborne debris"
TAS 202Uniform static air pressure (structural load). FBC 1709.5.1 requires HVHZ windows and sliding doors to comply with TAS 202
TAS 203Uniform cyclic pressure loading after impact

Florida's mitigation form treats "Miami-Dade County PA 201, 202, and 203" and "Florida Building Code Testing Application Standard (TAS) 201, 202, and 203" as top-level impact protection, alongside ASTM E1886 and E1996. The state emergency management guide notes that a product with a Miami-Dade Notice of Acceptance based on these protocols can be used in Miami-Dade and Broward.

What is the large missile impact test?

The large missile represents lumber and other heavy debris near the ground. In the HVHZ, FBC 1626.2.3 defines it as a 2x4 timber weighing 9 pounds, fired at 50 feet per second, or 80 feet per second for Risk Category IV essential facilities. TAS 201 matches: a nominal 2-by-4 piece of timber weighing 9 pounds (4.1 kg), fired from an air cannon, striking at 50 or 80 feet per second.

What does 50 feet per second mean in plain terms? The state emergency management guide describes the typical large missile test as "a 9-pound 2x4 lumber missile striking end on at 34 mph." At 80 feet per second, the speed is about 55 mph.

How the shots are placed (HVHZ)

  • Three specimens of the product are tested, under FBC 1626.2.
  • Each specimen takes two impacts: one within a 5-inch radius of the center, and one within a 5-inch radius circle centered 6 inches from the supporting members in a corner, under FBC 1626.2.5. The corner shot tests the frame and anchors, not just the glass.
  • Shutters must resist the impacts without deforming enough to touch the window, glass, door or skylight they protect, under FBC 1626.2.6.1.

Height limit

The HVHZ large missile test applies to assemblies used up to and including 30 feet above grade (FBC 1626.2). Outside the HVHZ, FBC 1609.1.2 requires glazed openings within 30 feet of grade to meet the large missile test of ASTM E1996.

What is the small missile test?

The small missile represents roof gravel and small debris that can fly higher. In the HVHZ, FBC 1626.3 uses solid steel balls weighing 2 grams each, 5/16 inch in diameter, fired at 130 feet per second (about 89 mph). Each specimen takes 30 impacts, delivered in groups of 10. TAS 201 describes the same steel balls at 130 feet per second (40 meters per second).

When is the small missile enough? (The 30-foot rule)

  • Outside the HVHZ, FBC 1609.1.2 says glazed openings more than 30 feet above grade must meet the small missile test of ASTM E1996.
  • In the HVHZ, the small missile test applies above 30 feet, but Risk Category IV buildings must still use the large missile at 50 feet per second at those heights (FBC 1626.3).
  • FBC 1609.1.2 also lets glazing in Risk Category II, III or IV buildings go unprotected if it is more than 60 feet above the ground and more than 30 feet above any roof with aggregate surfacing (such as gravel) within 1,500 feet.

In practice, this means a condo tower may have large missile units on lower floors and small missile units higher up. If you own a unit on the fourth floor of a building, ask whether your windows are above or below the 30-foot line, because it changes which products qualify. See our high-rise condo window guide.

Missile table: what each test uses

Here are the missiles named in the Florida code and the state mitigation form, in one place. Every value below comes from the Florida Building Code, TAS 201 as described by Intertek, or Florida's OIR-B1-1802 form.

MissileMassSpeedWhere it is usedSource
Small missile (steel balls, 5/16 in)2 grams each, 30 impacts130 ft/s (about 89 mph)Above 30 ft; HVHZ above 30 ft except Risk Category IVFBC 1626.3; TAS 201
Large missile, standard (2x4)9 lb50 ft/s (about 34 mph)Within 30 ft of grade; HVHZ standard large missileFBC 1626.2.3; TAS 201
Large missile, essential facilities (2x4)9 lb80 ft/s (about 55 mph)HVHZ Risk Category IV buildingsFBC 1626.2.3
Lighter large missile (ASTM)4.5 lbPer ASTM E1996Credited as Level B on the wind mitigation formOIR-B1-1802
Skylight large missile4.5 lb for top credit; Level B is 2 lb in the form's level chart and 2 to 4.5 lb in its answer textPer ASTM E1996SkylightsOIR-B1-1802
SSTD 12 large missile (older standard)4 to 8 lbPer SSTD 12Credited as Level B on the form for older productsOIR-B1-1802

What are ASTM missile levels A, B, C, D and E?

ASTM E1996 names its missiles with letters, from a small steel-ball missile up through heavier 2x4 missiles. The required letter level depends on the wind zone and the building's needed protection. The small steel-ball missile and the 9-pound 2x4 at 50 feet per second are the two tests most homeowners will see on Florida test reports. The full ASTM table of levels is in the standard itself, which ASTM sells; the free summaries we checked disagreed on at least one level's weight, so we do not reprint it here. Read the test report for your product: it will name the missile level, the wind zone and the cyclic pressure used.

Do not confuse ASTM levels with the wind mitigation form's levels

Florida's wind mitigation form also uses letters, and they mean something different. On the form, "A" means verified cyclic pressure and large missile protection (9 lb for windows and doors, 4.5 lb for skylights), "B" means a 4 to 8 lb missile (2 lb for skylights in the level chart), "C" means plywood or OSB, "N" means unverified, and "X" means none. An inspector's "Level A" is not the same thing as an ASTM "Missile Level A." See our wind mitigation form guide.

What is cyclic pressure testing (9,000 cycles)?

Surviving the hit is only half the test. After impact, the product must hold together while the storm keeps gusting for hours. Cyclic testing simulates that by pushing and pulling on the damaged specimen over and over.

In the HVHZ, FBC Table 1626 applies 9,000 total cycles, 4,500 inward and 4,500 outward, each lasting 1 to 3 seconds, at pressures up to Pmax, which the code sets at 0.6 times the ultimate design load per ASCE 7. The Florida Department of Emergency Management guide describes the cyclic test as about four hours or more of positive and negative pressure cycles, or about 9,000 cycles, which "tests fatigue resistance and fastener attachment." It adds that products must pass the cyclic tests, not just the missile test, to qualify as large missile resistant.

How a product passes

  • HVHZ: under FBC 1626.2.8, a system passes if all three specimens reject both missile impacts without penetration and survive the cyclic loading with no crack longer than 5 inches and wider than 1/16 inch through which air can pass.
  • Other standards: the state emergency management guide explains that Miami-Dade standards do not allow the missile to penetrate the system or break the glass behind it, while other standards allow penetration if the opening does not grow under pressure and a 3-inch sphere cannot pass through the hole afterward.

That is why an impact window can look shattered after a storm and still have done its job. Laminated glass is designed to crack and stay in the frame, keeping the envelope closed. After any storm, an impact unit with cracked glass needs repair or replacement, and Florida's mitigation form marks damaged openings as "Z," which removes the discount until fixed.

Higher protection: what about hospitals, shelters and other essential facilities?

Buildings that must keep working after a storm get tougher requirements. The Florida Building Code puts hospitals with surgery or emergency treatment, fire, rescue, ambulance and police stations, and designated hurricane shelters in Risk Category IV. Those buildings use a higher wind speed map (Figure 1609.3(3)), which raises their design pressures.

In the HVHZ, Risk Category IV buildings must pass the large missile at 80 feet per second instead of 50, and must use the large missile even above 30 feet (FBC 1626.2.3 and 1626.3). Outside the HVHZ, the design professional selects the ASTM E1996 level that matches the building's risk category and wind zone. If you manage a clinic, school used as a shelter, or emergency facility, ask your engineer which level applies before ordering products. See our commercial building guide.

How are skylights, garage doors, louvers and glass block tested?

OpeningStandard or ruleSource
SkylightsASTM E1886 and E1996. For top credit on the mitigation form, a 4.5 lb large missile; Level B is listed as 2 lb in the form's chart and 2 to 4.5 lb in its answer text. In the HVHZ, skylights must meet impact criteria or be protectedOIR-B1-1802; FBC 1626.1
Garage doorsANSI/DASMA 115 for missile impact and cyclic wind pressure on sectional, rolling and flexible doors (2005, 2012 or 2017 editions), or another approved impact standardFBC 1609.1.2.3; FBC Chapter 35
Fenestration (windows, doors) alternativeAAMA 506-16, impact and cycle testing of fenestration productsFBC Chapter 35; FBC Residential R301.2.1.2
Louvers within 30 ft of gradeAMCA 540, or an impact-resistant cover meeting the ASTM E1996 large missile testFBC 1609.1.2.1
Glass blockListed as a glazed opening on the mitigation form; HVHZ envelope rule covers glass blockOIR-B1-1802; FBC 1626.1

In Texas, TDI says garage doors must be tested to ASTM E330 for wind pressure, glass panels should be rated to ASTM E1996, and impact protective systems must also be tested to ASTM E330. See our garage door guide and skylights guide.

Who performs these tests (accredited labs)?

Florida law sets who can produce the test evidence behind an approval. Under s. 553.842(8)(b), the Florida Building Commission may approve testing laboratories "accredited by national organizations, such as A2LA and the National Voluntary Laboratory Accreditation Program," labs accredited by approved evaluation entities, and labs meeting other Commission guidelines. Every entity involved must show independence from the manufacturer. Miami-Dade adds its own requirement: test labs used for Miami-Dade product approvals must also be Miami-Dade certified.

A homeowner does not need to vet the lab. The approval process does that. What you can do is read the approval: it names the test standards and the test report or evaluation. If the paperwork you are handed shows a test report but no Florida or Miami-Dade approval number, that is not enough for a Florida permit. See our product approval lookup guide.

Independent research labs also test whole buildings. IBHS tests full-size homes in a South Carolina facility under wind-driven rain, hail and winds up to 130 mph. Those tests inform standards such as FORTIFIED but are not a substitute for the code-required product tests.

Older standards, plywood and what Texas requires

SSTD 12 and other legacy standards

SSTD 12 (Southern Standards Technical Document 12) was an earlier impact standard. The state emergency management guide says SSTD-12-97 was accepted in Florida until December 31, 2007 and is no longer accepted for new products, though older products that comply are considered to practically meet ASTM E1886 and E1996. The 2026 mitigation form still lists SSTD 12 so inspectors can credit older installations.

Plywood is a code exception, not a tested product

The FBC allows wood structural panels at least 7/16 inch thick, with a maximum 44-inch span between fastener lines, as opening protection on one- and two-family homes (Group R-3 or R-4) with a mean roof height of 33 feet or less where Vult is 180 mph or less. Panels must be precut, predrilled, overlap the wall at least 2 inches beyond the fastener lines, and use corrosion-resistant hardware permanently installed on the building. This is a prescriptive exception, not an impact test result, and the mitigation form credits it as "C." See our plywood guide.

Texas

Texas uses ASTM E1886 and E1996 through the International Residential and Building Codes. TDI tells homeowners to "always use products that have been tested to one of these standards," designated by a recognized product approval, and warns that a "Force 12" wind rating only meets the minimum of a Category 1 hurricane (74 mph). Since April 1, 2026, coastal windstorm certification uses the 2024 IRC or IBC, and TDI says most of its designated catastrophe areas now fall inside the windborne debris region. See our Texas coastal code guide.

How to choose a provider

  • Find the FL approval or Miami-Dade NOA number for every impact product.
  • Read which standards were used: ASTM E1886/E1996, TAS 201/202/203, AAMA 506 or ANSI/DASMA 115.
  • Confirm the missile type fits the opening height (large missile within 30 ft of grade).
  • In Miami-Dade or Broward, confirm HVHZ approval.
  • For essential facilities, confirm the higher missile speed or level with your engineer.
  • Check the wind zone on the test report matches your site's wind speed.
  • Check design pressure separately from impact rating.
  • Keep labels and approvals for your wind mitigation inspection.

Related hurricane shutters and impact windows guides

Hurricane shutters and impact windows by state and city

Questions people ask

What weight is the 2x4 used in hurricane impact tests?

The standard large missile is a 2x4 weighing 9 pounds. The Florida Building Code's HVHZ section (1626.2.3) and TAS 201 both specify 9 pounds, fired at 50 feet per second, or 80 feet per second for Risk Category IV essential facilities. Florida's wind mitigation form gives its top opening credit to products tested with the 9-pound missile for windows and doors (4.5 pounds for skylights).

How fast is the missile fired?

The 9-pound 2x4 is fired at 50 feet per second, which the Florida Division of Emergency Management describes as about 34 mph, striking end on. For essential facilities in the HVHZ the speed is 80 feet per second, roughly 55 mph. The small missile, 2-gram steel balls, is fired at 130 feet per second, about 89 mph, with 30 impacts per specimen in groups of 10.

Is ASTM testing as tough as Miami-Dade TAS testing?

Both are recognized for top credit on Florida's mitigation form, and both include large missile impact followed by cyclic pressure. They differ in details. The state emergency management guide notes that Miami-Dade standards do not allow the missile to penetrate the system, while other standards allow penetration if the hole does not grow under pressure and a 3-inch sphere cannot pass. In Miami-Dade and Broward the HVHZ protocols or an HVHZ approval are required.

Does an impact window have to stay unbroken to pass?

No. The glass can crack. In the HVHZ, a product passes if all three specimens resist both impacts without penetration and survive 9,000 pressure cycles with no crack longer than 5 inches and wider than 1/16 inch that air can pass through. Laminated glass is meant to crack and hold. After a real storm, cracked impact glass should be repaired or replaced.

Do windows above the third floor need impact glass?

Usually some protection is still required. Outside the HVHZ, glazing more than 30 feet above grade must pass the small missile test. Glazing can go unprotected only if it is more than 60 feet above ground and more than 30 feet above any aggregate-surfaced roof within 1,500 feet. In the HVHZ, Risk Category IV buildings need the large missile test even above 30 feet.

What does 'Wind Zone 3' on my test report mean?

It refers to the ASTM E1996 wind zones as Florida rewrites them in FBC 1609.1.2.2. Zone 3 covers ultimate design wind speeds of 150 to 170 mph, or 140 to 170 mph within one mile of the coastline. A product tested for Wind Zone 3 is meant for those conditions. Zone 4 is above 170 mph and calls for tougher test conditions.

Are plywood panels impact tested?

Not as a product. The Florida Building Code allows 7/16-inch wood structural panels as a prescriptive exception for one- and two-family homes up to 33 feet mean roof height where the wind speed is 180 mph or less, with precut panels and permanent anchors. Florida's wind mitigation form credits properly installed plywood or OSB as Level C, below tested products at Level A or B.

How do I know which test my shutters passed?

Look at the permanent label. FBC 1709.9 requires shutter labels to list the approval holder, the approval methods (such as Miami-Dade NOA or Florida Building Commission), the test standards used, and the Florida approval or NOA number. Then look up the approval online to read the test details. If there is no label or paperwork, a wind mitigation inspector will likely mark the shutters as unverified.

Does Texas accept Miami-Dade or Florida tested products?

Texas asks for products tested to ASTM E1886 and E1996 with a recognized product approval, and the TDI-appointed inspector or engineer decides what is accepted for windstorm certification. Florida's own code recognizes TDI Product Evaluation as an approval method on shutter labels. Many products carry several approvals. Confirm with the inspector before you buy for a coastal Texas home.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration