What Size Solar System Do I Need? How Many Panels for a Texas or Florida Home

Size solar from 12 months of kWh use, local production per kW, and, most important in Texas and Florida, how your utility values the power you export. This guide walks through the math step by step, with city production data, roof-space limits and the utility rules that cap or shrink the right size.

Add up the last 12 months of kWh from your bills, then divide by how many kWh one kW of panels makes per year where you live, about 1,420 to 1,510 in Houston, Dallas, Austin and San Antonio and 1,455 to 1,570 in Jacksonville, Orlando, Miami and Tampa, based on PVWatts. A home using 15,000 kWh a year needs about 10 kW. In Texas, exports to a retail plan are usually worth less than retail, so size smaller. On Florida's big utilities, size close to 100% and not beyond.

Key facts

  • PVWatts models a south-facing, 20 degree tilt array at about 1,421 kWh per kW per year in Houston, 1,483 in Austin, 1,497 in San Antonio and 1,506 in Dallas.
  • PVWatts models the same array at about 1,455 kWh per kW per year in Jacksonville, 1,544 in Orlando, 1,552 in Miami and 1,568 in Tampa.
  • Texas Utilities Code 39.916(j): in competitive areas, surplus solar is sold to your retail electric provider at a value you agree on; there is no statewide net metering rate.
  • Texas Utilities Code 39.916(k): a customer whose system is sized so estimated annual production does not exceed estimated annual use is not an electric utility or retail provider and need not register with the PUC.
  • Florida Rule 25-6.065: AC gross power rating is DC nameplate x 0.85; Tier 1 is up to 10 kW AC, and expedited interconnection requires a rating no more than 90% of your service rating.
  • Florida IOU net metering carries excess credits up to 12 months, then pays leftovers at year end at the lower COG-1 as-available rate, so oversizing has little payoff.
  • Berkeley Lab (via Mercom): the median U.S. residential system was 7.7 kW in 2025; EnergySage's average quoted system was 13.38 kW in Texas and 14.49 kW in Florida (Nov 2026).
  • Berkeley Lab: residential arrays typically cover about 15% to 40% of total roof area (median 26% in 2023), and median residential module efficiency reached 20.8% in 2023.
  • Florida Fire Prevention Code (NFPA 1, 11.12), as presented by Miami-Dade County: one- and two-family homes need a 3-foot clear pathway from eave to ridge and modules at least 3 feet below the ridge.

kW vs kWh: the two numbers you need to understand

Solar sizing uses two different units, and sales pitches often blur them.

  • kW (kilowatt) is power, a rate. A "10 kW system" means the panels' combined nameplate rating is 10,000 watts of DC power under standard test conditions. Think of it like the size of a pipe.
  • kWh (kilowatt-hour) is energy, an amount. Your electric bill charges you per kWh. Think of it like the gallons that flow through the pipe over time.

A 10 kW system does not make 10 kWh. It makes about 14,000 to 15,700 kWh per year in Texas and Florida cities, depending on location, roof direction, tilt and shade. Your job is to match the kWh the system makes to the kWh you can use or get paid fairly for.

One more pair: DC vs AC. Panels make DC power; inverters convert it to the AC power your home uses. System size is normally quoted in kW DC. Florida's net metering rule converts to AC by multiplying DC by 0.85 for tier purposes.

Step 1: Get 12 months of kWh use

Do not size from one bill. Texas and Florida homes use far more power in summer than in spring, so one month misleads.

In Texas

  • Your bill from your retail electric provider lists kWh used per billing period, and many show a 12-month history.
  • Smart Meter Texas holds usage data from the advanced meters run by the poles-and-wires utilities in competitive areas, such as Oncor and CenterPoint. Your bill lists your ESI ID (Electric Service Identifier), the number that identifies your service point. Oncor says customers can see daily and monthly energy data recorded in 15-minute intervals by their smart meter at SmartMeterTexas.com. That time-of-day detail matters for Texas sizing (see Step 4).
  • Austin Energy, CPS Energy and co-op customers get history from their utility's online account.

In Florida

  • FPL, Duke Energy Florida, Tampa Electric and the city utilities all show usage history in their online accounts. OUC's solar FAQ tells customers to get the past 12 billing cycles from their myOUC account or customer service.

Write down: the 12-month total, the highest month, the lowest month, and anything unusual (a new pool, an EV, a home office, a broken AC that ran nonstop).

Only have a few months of bills, or a new home?

Ask the utility for the address's history (some provide it to new occupants), use a similar neighbor's home as a guide, or size conservatively and leave room to add panels later. In Florida, adding capacity later requires a new interconnection application at least 30 days before the change under Rule 25-6.065. See solar on new construction.

Step 2: Find how much 1 kW of panels makes where you live

The free PVWatts model from the National Laboratory of the Rockies (formerly NREL) estimates production for any address. We ran it for a 1 kW array facing due south at a 20 degree tilt with standard panels and the default 14% losses. These are modeled typical-year figures, not measurements.

CitykWh per kW per yearBest month (kWh per kW)Weakest month (kWh per kW)A 10 kW system, per year
Houston1,421140 (July)86 (December)about 14,210
Dallas1,506155 (July)98 (February, November)about 15,060
Austin1,483154 (August)94 (February)about 14,830
San Antonio1,497151 (July, August)95 (February)about 14,970
Jacksonville1,455146 (May)92 (December)about 14,550
Orlando1,544153 (May)106 (December)about 15,440
Miami1,552152 (March)110 (December)about 15,520
Tampa1,568152 (May)109 (December)about 15,680

Notice the seasonal shape. Texas systems peak in July and August, close to when air conditioning use peaks. Florida systems peak in spring and stay flatter through the year, because summer afternoon storms cut into the longest days. OUC uses a more conservative rule of thumb on its own sizing page: about 1,350 kWh per kW per year in Orlando.

Run PVWatts for your own roof. Enter your address, the roof's direction (azimuth: 180 is south, 270 is west, 90 is east) and pitch. East- and west-facing roofs produce less per kW than south-facing ones over a year, and shade cuts output further. Berkeley Lab found 56% of systems installed in 2023 faced south and 23% faced west.

Step 3: Do the basic math

System size (kW DC) = annual kWh you want to cover / kWh per kW per year

Examples, using the PVWatts figures above:

HomeAnnual useTargetMathSize
Dallas, 3-bedroom14,000 kWh100%14,000 / 1,506about 9.3 kW
Houston, 2-story20,000 kWh100%20,000 / 1,421about 14.1 kW
Tampa, with pool18,000 kWh100%18,000 / 1,568about 11.5 kW
Orlando (OUC's example)18,000 kWh100%18,000 / 1,350about 13.3 kW
Jacksonville, smaller home11,000 kWh100%11,000 / 1,455about 7.6 kW

How many panels? Divide the size in watts by the panel's wattage. A 9.3 kW system with 400-watt panels is 9,300 / 400 = about 23 to 24 panels. With 430-watt panels it is about 22. Panel wattage is on the spec sheet and should be in your quote.

Why the answer is never "by square foot of house." A 2,000 square foot house in Houston with an old AC unit, a pool and an EV can use twice as much power as a 2,000 square foot house in Miami with a new heat pump and no pool. Size by kWh, not floor area. If you need a starting guess before you have bills, use a similar home's usage, never a per-square-foot rule.

For context, Texas and Florida systems run large. Berkeley Lab found the median U.S. residential system was 7.7 kW in 2025, while EnergySage's average quote was 13.38 kW in Texas and 14.49 kW in Florida as of November 2026.

Step 4: Adjust for what your utility pays for exports

This is the step most sizing calculators skip, and in Texas and Florida it changes the right answer more than anything else.

Every solar home does two things with its power: it uses some directly as it is made (self-consumption), and it sends the rest to the grid (exports). A self-consumed kWh saves you your full energy rate. An exported kWh is worth whatever your utility or retail plan pays for it. When exports are worth less, extra panels are worth less too.

Your utility situationHow exports are valuedSizing approach
Florida investor-owned utility (FPL, Duke Energy Florida, Tampa Electric, FPUC)Full value against your use within the year; leftovers paid at year end at the COG-1 as-available rate (Rule 25-6.065)Size close to 100% of annual use; going beyond mostly earns the low year-end rate
JEA (Jacksonville)Exports credited at JEA's fuel rate; purchases at standard ratesSize for daytime self-use; consider smaller or add storage
OUC (Orlando), new customers since July 1, 2025Community Solar Energy Rate for five years, then retail levelized fuel rateSize for daytime self-use; compare value of storage
Texas competitive area (Houston, Dallas-Fort Worth and others)Whatever your retail plan's buyback terms say; no statewide net metering; PUC says buyback is usually below the retail priceSize toward self-consumption, unless you have a plan that credits exports near retail and you trust it to last
Austin EnergyValue of Solar: all solar production credited at 12.89 cents per kWh (from Oct 2026); all use billed at standard rates; excess credit carries over but applies only to electric chargesSize so yearly credits do not exceed your yearly electric charges
CPS Energy, co-ops, other city utilitiesSet by each utilityGet the written policy first

Texas: why smaller can be smarter

Texas Utilities Code 39.916(j) says that in competitive areas, solar owners sell surplus electricity to the retail electric provider serving them at a value they agree on. That value may be based on the energy clearing price or a carried-over bill credit. The PUC's 2026 consumer guide says the buyback rate is usually lower than the retail price you pay. Also, delivery charges from the wires utility (Oncor, CenterPoint, AEP Texas, TNMP) are billed on the kWh delivered to you, and exports do not reduce them.

Example: a Dallas home uses 14,000 kWh a year. It is mostly empty on weekdays. Smart Meter Texas interval data shows about 40% of the home's use happens during daylight. A 9.3 kW system sized to 100% would make about 14,000 kWh, but the home could use only part of that as it is made, and would export the rest at the buyback rate. A 6 kW system (about 9,000 kWh) would export less, so a bigger share of its output earns the full retail value. The smaller system may save almost as much per year at a much lower price. The right size depends on your interval data and your plan's buyback rate; run both sizes through the payback math.

There is also a legal reason not to oversize in Texas. Under 39.916(k), a customer whose system is sized so estimated annual production is no more than estimated annual use is not treated as an electric utility or retail provider and does not have to register with the PUC.

For buyback plan types, see Texas solar buyback plans.

Florida: why bigger is not better

On FPL, Duke Energy Florida, Tampa Electric and FPUC, the 12-month carryover lets spring surpluses cover summer use at full value. But at the end of each calendar year, unused credits are paid at an average annual rate based on the utility's COG-1 as-available energy tariff, an energy-only rate well below retail. A system sized at 130% of use sends about a quarter of its output to that low rate. Size near 100%, and slightly under if your use is falling (new AC, LED lights, kids moving out).

Florida's rule also defines customer-owned renewable generation as a system primarily intended to offset part or all of the customer's electricity requirements. OUC states directly that system capacity should not exceed the home's energy needs. We could not confirm a specific published percentage cap relative to usage for FPL or Duke Energy Florida; ask your utility's interconnection team before you sign if your design exceeds your annual use.

Florida tier limits: why 10 kW AC is a common ceiling

Florida Rule 25-6.065 sorts systems into tiers by AC gross power rating, which for inverter systems equals DC nameplate times 0.85.

TierAC gross power ratingAbout this much DCWhat changes
Tier 1Up to 10 kWup to about 11.7 kW DCNo extra fees, including application fees; no liability insurance requirement
Tier 2Over 10 kW to 100 kWabout 11.8 to 117 kW DCApproved application fee allowed; liability insurance up to $1 million may be required
Tier 3Over 100 kW to 2 MWabout 118 kW DC and upFees, possible interconnection study, insurance up to $2 million

So a Florida home that needs 12 kW DC to cover 100% of use crosses into Tier 2. Before you add the last few panels, ask whether the extra production is worth the paperwork and any fee or insurance. Municipal utilities use similar tiers; OUC lists no fee for Tier 1, $340 for Tier 2 and $1,300 for Tier 3.

The rule also caps expedited interconnection at a system rating of no more than 90% of your utility distribution service rating. For most homes this is not the binding limit, but very large systems on small services can hit it. See Florida net metering explained.

In Texas, Utilities Code 39.916 defines distributed renewable generation as up to 2,000 kW and requires utilities to allow interconnection if the system has a five-year warranty against breakdown or undue degradation and does not exceed the customer's service capacity.

Step 5: Check that it fits on your roof

Roof space often limits size before your usage does. Work it out in this order.

Panel area

Look up the panel's dimensions on the spec sheet. For example, a panel measuring 1.1 by 1.8 meters covers about 2 square meters, or about 21 square feet. Twenty-four of those cover about 510 square feet of panel surface, before gaps and setbacks.

Efficiency matters here. Berkeley Lab found median residential module efficiency rose from 12.7% in 2002 to 20.8% in 2023, and has risen about 0.4 percentage points a year over the long term. Higher-efficiency panels put more watts on the same roof, which helps on small or crowded roofs.

Fire code access pathways

Firefighters need clear paths on the roof. Miami-Dade County's PV permitting presentation summarizes Florida Fire Prevention Code (NFPA 1, section 11.12) rules for one- and two-family homes and townhouses:

  • A 3-foot-wide clear access pathway from eave to ridge on each roof slope with panels.
  • On single-ridge roofs, two 3-foot pathways from eave to ridge on each slope with panels.
  • Panels no closer than 1.5 feet to a hip or valley if panels are on both sides of it.
  • Panels at least 3 feet below the ridge.

These rules can remove a large share of a small roof. Texas has no single statewide residential fire code for solar; cities adopt their own codes and local amendments, and pathway rules vary. Ask your installer which code edition and local amendments the plans follow, and confirm with your city's building or fire department. Code editions change, so check the current one in Florida too.

Real-world coverage

Berkeley Lab found residential arrays typically cover about 15% to 40% of total roof area, with a median of 26% in 2023. If your design covers much more than that, look closely at shading and pathway compliance.

HOA placement rules

In Texas, Property Code 202.010 lets an HOA designate where on the roof panels go, unless an alternate location would increase estimated annual production by more than 10%, measured with a public NREL tool such as PVWatts. In Florida, Statute 163.04 lets an association choose the specific roof location within an orientation to the south or within 45 degrees east or west of due south, as long as that does not impair the panels' effective operation. Both can change how many panels fit on the best roof faces. See HOA solar rights.

Shade, orientation and tilt

PVWatts lets you enter a roof's direction and tilt and add extra losses for shade. As a rule, south-facing roofs produce the most over a year, west-facing roofs produce more in late afternoon, and north-facing roofs are rarely worth covering. Run your own roof's numbers rather than relying on a rule of thumb.

Shade from trees, chimneys or a neighbor's second story reduces output, and on a string inverter one shaded panel can drag down others in the same string. Microinverters and optimizers reduce that effect. A professional shade analysis (most installers use a tool that reports solar access as a percentage) should be part of any quote. If shade cuts output, you need more kW to make the same kWh, or you accept covering a smaller share of your use. See roof orientation, shade and trees.

DC-to-AC ratio and clipping, explained

The DC-to-AC ratio, also called the inverter loading ratio (ILR), compares the panels' total DC rating with the inverter's AC rating. A 12 kW DC array on a 10 kW AC inverter has a ratio of 1.2.

Designers often use a ratio above 1.0 because panels rarely produce their full nameplate output. Heat, dust, wire losses and sun angle keep real output below the rating most of the time. A slightly smaller inverter can therefore handle the array almost all of the time, at lower cost.

Clipping is what happens on the rare moments when the panels could make more than the inverter can pass. The inverter caps output at its AC limit and the extra is lost. A small amount of clipping on the sunniest spring middays is normal and can be a good design trade. A lot of clipping wastes the panels you paid for. Ask the designer for the expected annual clipping loss in the production estimate.

Berkeley Lab reports that inverter loading ratios for residential systems have risen steadily over time. In Florida, the net metering tier is based on DC times 0.85, not the inverter rating, so a high DC-to-AC ratio does not lower your tier.

Sizing for a pool, an EV or other new loads

Add new loads to your annual kWh before you divide. Use the device's own numbers.

  • Pool pump: watts from the nameplate x hours per day x days per year / 1,000. Example: a 1,500-watt single-speed pump running 8 hours a day all year is 1,500 x 8 x 365 / 1,000 = about 4,380 kWh a year. In Tampa that alone needs about 2.8 kW of panels. A variable-speed pump running at lower speed uses far less, so an efficiency upgrade may beat adding panels. See solar and pool heating.
  • EV: miles per year x kWh per mile (from the vehicle's efficiency label or app). Example: 12,000 miles x 0.30 kWh per mile = 3,600 kWh a year, about 2.4 kW of panels in Dallas. Charging mostly at night means the EV's use will not be self-consumed; in Texas that matters. See EV charging with solar.
  • Home office or new AC: look at the change on your bills once it has run for a few months.

Can I oversize for a future EV? You can, within limits. In Florida, a system bigger than current use builds credits paid at the low year-end rate until the EV arrives. In Texas, oversizing raises exports at buyback value and can push production above use, which matters under Utilities Code 39.916(k). Planning conduit and inverter capacity for later expansion is often a better plan than buying the panels now.

How many panels for a 2,500 kWh summer bill?

Do not size to your peak month. Size to the year. Suppose a Houston home's highest bill shows 2,500 kWh in August, but its 12-month total is 21,000 kWh.

  • Sized to the peak month: 2,500 kWh / 140 kWh per kW (Houston's best month) = about 17.9 kW. That would make about 25,400 kWh a year, far more than the home uses.
  • Sized to the year: 21,000 / 1,421 = about 14.8 kW, or about 37 panels at 400 watts.
  • Sized for self-consumption on a low-buyback plan: smaller still, often well under 100%, depending on daytime use.

In Florida the same logic applies; a Miami home with a 2,500 kWh August and 22,000 kWh a year needs about 22,000 / 1,552 = 14.2 kW to cover 100%, which would put it in Tier 2.

Should I size to 100% of my usage?

SituationReasonable target
Florida IOU, full monthly net metering, staying long termAbout 90% to 100% of annual use
Florida IOU, wanting to stay in Tier 1Up to about 11.7 kW DC, even if that covers less than 100%
Florida city utility or co-op with low export rateDaytime self-use, often well under 100%
Texas retail plan with low or wholesale-based buybackDaytime self-use; check interval data
Texas plan crediting exports near retailUp to 100%, knowing plan terms can change at renewal
Austin Energy Value of SolarYearly credits no larger than yearly electric charges
Adding a batteryEnough solar to recharge the battery on a typical day plus daytime use

These targets are starting points, not rules. The best size is the one that gives the lowest cost per useful kWh, which you can find by running two or three sizes through the payback calculation.

Cut your usage before you size

Every kWh you stop using is a kWh you do not need panels for. Fix the big loads first: an aging air conditioner, poor attic insulation, duct leaks, a single-speed pool pump, an old electric water heater. Then size solar to the lower usage. If you size first and upgrade later, you end up with more panels than you need, which in Florida earns the low year-end rate and in Texas earns buyback rates. OUC and other utilities offer free energy assessments. See efficiency first, then solar.

Does a battery change the system size?

A battery lets you use more of your own solar later in the day, which raises the value of panels on a low-export plan. It needs enough solar to recharge it. Berkeley Lab found the median residential battery paired with solar was 13.5 kWh in 2025. Charging that once a day takes about 13.5 kWh plus losses, which is roughly what 3 to 3.5 kW of panels make on an average day in these cities. For backup during outages, size the battery to your critical loads and the solar to recharge it. See home battery types and sizing.

How to choose a provider

  • Total your last 12 months of kWh (Smart Meter Texas or your utility's online account).
  • Note planned changes: new AC, pool pump, EV, efficiency upgrades.
  • Run PVWatts with your roof's real direction, tilt and shade.
  • Divide annual kWh by kWh per kW to get the 100% size.
  • Find out how your utility or retail plan values exports and adjust the size.
  • In Texas, download interval data to see how much you use during daylight.
  • In Florida, check whether the design stays under 10 kW AC (Tier 1) and whether that matters to you.
  • Confirm the design meets fire code pathways and any HOA placement rules.
  • Ask for the DC-to-AC ratio and the expected clipping loss.
  • Compare two or three sizes on cost per useful kWh before you sign.

Related residential solar installers guides

Residential solar installers by state and city

Questions people ask

What size solar system do I need?

Divide your annual kWh use by the kWh one kW of panels makes per year where you live. Using PVWatts, that is about 1,421 in Houston, 1,506 in Dallas, 1,483 in Austin, 1,497 in San Antonio, 1,455 in Jacksonville, 1,544 in Orlando, 1,552 in Miami and 1,568 in Tampa. A home using 15,000 kWh needs about 10 kW to cover 100%. Then adjust down if your utility or retail plan pays less than retail for exports.

How many kWh does a 10 kW system produce in Texas?

About 14,200 kWh a year in Houston, 14,800 in Austin, 15,000 in San Antonio and 15,100 in Dallas, based on PVWatts for a south-facing array at a 20 degree tilt with 14% losses. East- or west-facing roofs and shade reduce that. Output peaks in July and August.

How many kWh does a 10 kW system produce in Florida?

About 14,550 kWh a year in Jacksonville, 15,440 in Orlando, 15,520 in Miami and 15,680 in Tampa, from PVWatts for a south-facing 20 degree array. OUC uses a more conservative 1,350 kWh per kW in Orlando, or about 13,500 kWh for 10 kW. Florida output is fairly steady across the year and strongest in spring.

Why might FPL limit my system size?

Florida Rule 25-6.065 covers systems primarily intended to offset part or all of your own use and limits expedited interconnection to no more than 90% of your service rating. Systems over 10 kW AC move into Tier 2 with possible fees and insurance. We did not confirm a specific usage-based percentage cap in FPL's or Duke Energy Florida's published materials; ask the utility's interconnection team if your design exceeds your annual use.

How many solar panels do I need for a 2,000 square foot house?

Square footage does not decide it; your kWh use does. As an example, a Texas or Florida home using 15,000 kWh a year needs about 10 kW of panels to cover 100%, which is about 25 panels at 400 watts. A similar-sized home with a pool and older AC could need half again as many. Use 12 months of bills, not floor area.

Should I size differently in Texas without net metering?

Usually yes. Texas law sets no statewide net metering rate; surplus is sold to your retail provider at the plan's buyback terms, which the PUC says are usually below retail. Exports also do not reduce delivery charges. Sizing closer to what your home uses during daylight raises the value of each panel. Use Smart Meter Texas interval data to see your daytime use.

How much roof space do I need for solar?

Multiply the number of panels by each panel's area from the spec sheet, then add room for fire code pathways and setbacks. For example, 24 panels of about 21 square feet each need about 510 square feet of panel surface, plus clear 3-foot paths from eave to ridge and a 3-foot space below the ridge under Florida's fire prevention code. Berkeley Lab found arrays typically cover 15% to 40% of total roof area.

Can I add more panels later?

Usually, if the inverter, wiring and roof space allow it. In Florida, Rule 25-6.065 requires a new application to the utility at least 30 days before you increase the system's gross power rating, and a larger system may move into a higher tier. In Texas, the wires utility must approve the change. Adding later can cost more per watt than doing it once, so plan conduit and inverter room up front if you expect an EV.

What is a good DC-to-AC ratio?

There is no single right number; it depends on climate, orientation and inverter cost. Ratios somewhat above 1.0 are common because panels rarely reach full nameplate output, and Berkeley Lab reports residential ratios have risen over time. Ask the designer for the ratio and the modeled annual clipping loss. A small loss is a normal trade-off; a large one wastes panels.

Sources

This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.

New ebook from The Company ChronicleHow to Research Like a Wall Street AnalystFind original sources, analyze trends, and build your own insights. 36 pages with worksheets.Get the ebook · $29Instant PDF download

Business Spotlight

Want us to publish your business?

Our team writes and publishes articles about your business on The Company Chronicle every month, with a link to your website. Plans from $30 a month, cancel anytime.

Publish with us

The Chronicle directory

What are you into?

The Chronicle, coast to coast

Every corner has a story.

The full Chronicle illustration