Why Is My Solar System Producing Less Than Expected?
Low solar output usually comes down to one of a few causes: weather, a tripped breaker or inverter fault, lost monitoring, shade or dirt, normal aging, or a system that was oversold from the start. This guide shows Texas and Florida owners how to tell which, how to read the app and the bill, and what to do next, including when the installer is gone.
Start by comparing this month to the same month last year and to a PVWatts estimate for your exact system, because weather alone can swing a month by 30 percent or more. Then check the inverter for a fault light, the breakers and rapid shutdown switch, and whether monitoring is still connected. Gradual drops point to shade, dirt or aging; sudden drops point to a fault. Never open equipment yourself. Call a licensed electrician, and use your warranty and state complaint agencies if the installer will not respond.
Key facts
- PVWatts' manual says its typical-weather estimates can be off by up to 10 percent annually and 30 percent monthly, and a real year can differ from average by up to 20 percent annually and 40 percent monthly.
- PVWatts estimates about 1,421 kWh per kW per year in Houston, 1,506 in Dallas, 1,552 in Miami and 1,568 in Tampa for a south-facing, 20-degree roof array with default losses.
- A review by NREL (now the National Laboratory of the Rockies) of nearly 2,000 field measurements found a median degradation rate of 0.5 percent per year; PVWatts adds a typical 1.5 percent first-year light-induced degradation loss.
- Florida Rule 25-6.065 requires inverters that automatically disconnect when the grid goes down, and net metering customers still pay the customer charge regardless of exports.
- Oncor says its meters measure both consumption and surplus energy, with data sent to retail electric providers and Smart Meter Texas.
- Texas Bus. and Com. Code ch. 115 requires sellers to give buyers, in writing, any performance or financial representations and all warranties.
- TDLR takes complaints against Texas solar retailers for contracts signed on or after Sept. 1, 2025; earlier ones go to the Texas Attorney General.
- Texas Appleseed found that 45 percent of solar complaints to the Texas Attorney General from 2018 to mid-2024 cited false or misleading statements.
- A 2026 manufacturer manual warns that DC arcs from solar wiring are not self-extinguishing and are potentially lethal burn and fire hazards.
Start here: a five-minute check
Before you call anyone, run these checks. They solve a surprising share of "my solar stopped working" problems.
- Look at today's weather. Heavy cloud, smoke or storms cut output. Check a clear day before worrying.
- Open the monitoring app. Is it showing data from today? If the last data point is days old, the problem may be the internet connection, not the panels.
- Look at the inverter. String inverters and battery systems have a status light or screen. Green or normal usually means running; red, orange or an error code means a fault. Write down the code and take a photo.
- Check the breakers. Find the solar breaker in your main panel (often labeled PV or solar) and any solar disconnect switch near the meter. If a breaker is tripped, see the safety note below before resetting.
- Check the rapid shutdown switch. Newer systems have an outdoor shutdown switch near the meter or service disconnect. If someone turned it off, such as a roofer, pest company or a firefighter after a storm, the system will not produce.
- Think back. Was there a power outage, storm, roof work, new Wi-Fi router, or utility meter change recently?
Safety note on breakers: resetting a tripped breaker once is reasonable. If it trips again, stop. A repeat trip can mean a ground fault, failing inverter or damaged wire. Leave it off and call a licensed electrician. Do not open the inverter, combiner box or any cover, and do not touch roof wiring. A 2026 panel maker's manual warns that DC arcs are not self-extinguishing and are potentially lethal burn and fire hazards.
What is normal production for my system size?
A quick rule of thumb: multiply your system's kW-DC rating by the PVWatts annual figure for your city. These numbers are for a south-facing array at a 20-degree tilt with standard default losses, from the national lab's PVWatts model:
| City | kWh per kW per year | 6 kW system | 8 kW system | 10 kW system |
|---|---|---|---|---|
| Houston | 1,421 | 8,526 | 11,368 | 14,210 |
| Dallas | 1,506 | 9,036 | 12,048 | 15,060 |
| Austin | 1,483 | 8,898 | 11,864 | 14,830 |
| San Antonio | 1,497 | 8,982 | 11,976 | 14,970 |
| Miami | 1,552 | 9,312 | 12,416 | 15,520 |
| Tampa | 1,568 | 9,408 | 12,544 | 15,680 |
| Orlando | 1,544 | 9,264 | 12,352 | 15,440 |
| Jacksonville | 1,455 | 8,730 | 11,640 | 14,550 |
Your real number will be different if your panels face east or west, sit at a different tilt, get shade, or use premium equipment. East- and west-facing arrays usually make less per kW than south-facing ones. That is why the most useful baseline is a PVWatts run for your roof, not a city average.
How to run your own estimate
- Go to the free PVWatts calculator (pvwatts.nlr.gov) and enter your address.
- Enter your system size in kW-DC. This is the sum of all panel wattages, for example 24 panels x 400 W = 9.6 kW. It is on your contract and permit plans.
- Enter the tilt and azimuth (direction) of each roof face. South is 180, west is 270, east is 90. If you have panels on more than one face, run each separately and add them.
- Leave losses at the default 14 percent unless you know your shading. Increase losses if trees shade the roof.
- Compare the monthly results to your app's monthly totals.
Your installer's proposal should also have a production estimate. Texas law requires sellers to put performance representations in writing (Bus. and Com. Code ch. 115), so find that document. Our system sizing guide explains the estimate in more detail.
How do I compare expected and actual production fairly?
Compare the right things in the right time frame.
- Use months or a full year, not single days. The PVWatts manual says its estimates, built on typical weather, can be off by up to 10 percent for a year and 30 percent for a single month. A real year can vary from the long-term average by up to 20 percent annually and 40 percent monthly. A gray June in Tampa is not a broken system.
- Compare the same month year over year. July 2026 vs July 2025 is the cleanest check, because sun angle and day length match. Adjust for what you know: was this July unusually stormy?
- Account for aging. NREL's review of nearly 2,000 field measurements found a median degradation of 0.5 percent a year. PVWatts also builds in 1.5 percent of light-induced degradation, a one-time loss in the first months. A five-year-old system making 3 to 4 percent less than year one may be normal; check your panel warranty's guaranteed rate.
- Look at clear days. Pick a cloudless day and compare its output to a cloudless day a year ago in the same week. Clear days strip out most weather noise.
- Check the system was fully on all month. A week of downtime after a storm can explain a low month.
A simple weather adjustment
If your local weather service or monitoring app reports sun hours or solar irradiance, compare this month's figure to the typical month. If the month had about 15 percent less sun than normal and your output is about 15 percent below the estimate, the system is probably fine. If sunlight was normal and output is 25 percent low, something is wrong.
When is "low" really low?
| Gap vs estimate | Likely meaning |
|---|---|
| Within about 10 percent over a year | Normal variation for a typical year |
| 10 to 20 percent low for a year, weather was normal | Worth investigating: shade, soiling, a weak string, an optimistic estimate |
| More than 20 percent low, or a sudden drop | Likely a fault or a design problem. Call for service. |
| Zero production on a sunny day | System is off: breaker, shutdown switch, inverter fault, or grid outage |
How do I read my solar monitoring app?
Most apps show some version of four numbers. Know which is which:
- Production (solar): energy your panels made, in kWh. This is the number to compare against estimates.
- Consumption (home): energy your home used. Only shown if a consumption monitor was installed. Many systems have production monitoring only.
- Export (grid out): solar you did not use that went to the grid.
- Import (grid in): energy you bought from the grid.
Two units confuse people. kW is the rate of power right now, like speed. kWh is the amount of energy over time, like miles. A 10 kW system rarely shows 10 kW; on a hot, clear noon it might show 7 to 8 kW, because of heat and normal losses. Your bill is in kWh.
Panel-level and string-level views
- Microinverters and optimizers usually show each panel. A single panel at or near zero while its neighbors are normal points to that panel, its microinverter or optimizer, or a connector.
- String inverters may show each string (a chain of panels wired together). One string far below the other on a sunny day points to a problem in that string or shade on that roof face.
- Battery systems show charge level and flows. A full battery with no home load can make solar look low because the system has nowhere to send the power if export is limited.
See string inverters vs microinverters for how each design reports problems.
My monitoring stopped reporting. Is my system off?
Not necessarily. Monitoring and production are separate. A system can keep producing for months with no data reaching your phone. Common causes:
- New router or Wi-Fi password. The system's gateway or inverter is still trying to join the old network.
- Gateway unplugged. Many systems have a small gateway box plugged into an outlet near the router or panel. Someone may have unplugged it.
- Cellular modem lapsed. Some systems used a cellular link with a subscription or a network that has since shut down.
- Company app shut down or the account was tied to an installer that went out of business.
How to tell if the system is actually producing:
- Look at the inverter's light or screen on a sunny day.
- Look at your utility meter. Many net meters show delivered and received readings, and you can see export numbers rising at midday.
- Check your bill. If exports or credits disappeared, the system is probably off.
- In Texas competitive areas, Oncor and other wires utilities send your meter data to Smart Meter Texas and your retail electric provider. Oncor says its meters measure both consumption and surplus energy sent to the grid. Log in to Smart Meter Texas with your ESI ID (the meter ID on your bill) and look for exported energy on sunny days.
To fix the connection, find the gateway's manual or the manufacturer's homeowner support page. Most have a Wi-Fi setup step you can redo yourself without opening anything.
Why did my production drop suddenly?
A sudden drop, from normal one day to much lower or zero the next, almost always has a specific cause:
| What you see | Likely cause | What to do |
|---|---|---|
| Zero output, inverter dark | Solar breaker or AC disconnect off, rapid shutdown switch off, inverter lost power | Check breakers and switches once; if they trip again, call an electrician |
| Zero output, inverter shows grid error | Grid outage, high or low grid voltage, frequency out of range | Wait for the grid to stabilize; report repeated voltage errors to your utility |
| Zero output, inverter shows ground fault, isolation or arc fault | Damaged insulation, water in a connector, rodent damage, failing panel | Leave it off and call a licensed electrician. Do not reset repeatedly. |
| One string or roof face low | Failed connector, string fuse or breaker, new shade, debris | Look for shade or debris from the ground; schedule service |
| One panel low or zero (panel-level monitoring) | Failed microinverter or optimizer, bad connector, cracked or damaged panel, bird droppings | Check for visible spots; open a warranty claim for failed electronics |
| Output capped flat at midday | Inverter clipping, export limit, or heat derating | Usually normal if limited to a few midday hours; see the clipping section |
| Drop right after a storm | Panel, wiring or racking damage, debris | Inspect from the ground, photograph, call a pro and your insurer |
| Drop after roof or tree work | Disconnected wiring, shutdown switch left off, damaged conduit | Call the installer or an electrician; tell the roofer |
Could my system have tripped after a power outage?
Yes. Grid-tied inverters are required to shut off when the grid goes down. Florida's net metering rule calls for a utility-interactive inverter that automatically isolates from the grid when grid power is lost and ties interconnection to IEEE 1547 and UL 1741. Texas wires utilities such as Oncor treat systems certified to UL 1741 as the standard for home solar.
When the grid returns, a healthy inverter checks that voltage and frequency are stable and then restarts on its own, usually after a short wait. If yours did not:
- Check whether a breaker tripped during the outage or a surge.
- Look for a grid voltage or frequency error. Repeated high-voltage errors at midday can mean your neighborhood's voltage runs high. Report it to your utility: CenterPoint, Oncor, AEP Texas or TNMP in competitive areas; Austin Energy or CPS Energy in those cities; FPL, Duke Energy Florida, Tampa Electric, JEA or OUC in Florida.
- If you have a battery, check whether it is still in backup mode or needs to be switched back to normal operation in the app.
- If a rapid shutdown switch was turned off by firefighters or a utility crew, turn it back on only after any storm damage has been checked.
Oncor notes that during long outages it may not be able to read meters, so bills may be estimated and later corrected once actual readings reach Smart Meter Texas and your retail provider. A strange bill right after an outage may sort itself out on the next cycle.
What do inverter error codes mean?
Codes differ by maker, so the inverter manual or the maker's support site is the authority. Most fall into a few families:
- Grid errors (grid voltage high or low, frequency out of range, grid lost): the inverter is protecting the grid. Usually clears on its own. Frequent repeats need a utility or electrician check.
- Ground fault or isolation fault (also called insulation resistance or riso fault): current is leaking somewhere it should not, often from damaged wire insulation, water in a connector or a failing panel. Often worse in the morning when dew is present and better by noon.
- Arc fault: the inverter detected the electrical signature of an arc, such as a loose or damaged connection. It shuts down to prevent fire. Do not keep resetting it.
- Over-temperature: the inverter is too hot and is reducing output or shutting down. Check that vents are clear and the inverter is not in direct afternoon sun.
- Communication errors: the monitoring link failed. Production may be fine.
- Hardware faults: internal failure. This is a warranty claim.
Write down the exact code, the date and time, and the weather. Take photos of the screen. That record is what a service technician and a warranty department will ask for. See our solar warranties guide.
What is a ground fault on solar, and is it dangerous?
A ground fault means electricity is finding a path to ground through something it should not, like a nicked wire touching a metal rail, or water inside a connector. Inverters test for this and stop producing when they find it, which is a safety feature doing its job.
It can be dangerous to people who poke at the system. Panels make DC voltage whenever light hits them, and you cannot turn off the sun. A string of panels in series can add up to hundreds of volts. The manufacturer manual we reviewed says the voltage of panels in series can be dangerous and warns against handling damaged or dirty cables. Treat any ground fault or arc fault as a call for a licensed electrician who has solar experience and the meters to find the fault.
In Texas, that means a TDLR-licensed electrician working for a licensed electrical contractor; TDLR says non-exempt electrical work requires both. In Florida, a licensed solar contractor or electrical contractor. Check licenses at TDLR's license search or the DBPR lookup.
How do I check if a microinverter or optimizer failed?
- Open the panel-level view in the app on a sunny day.
- Look for a panel reading zero, or a panel that has reported no data for days, while its neighbors read normally.
- Check whether the same panel is low every day or only at certain hours. If only in the morning or afternoon, it may be shade. If all day, it is likely a hardware or connection problem.
- Look from the ground for a visible cause: a bird dropping, debris, a cracked panel.
- If nothing is visible, open a warranty claim with the electronics maker or your installer. Note that many microinverter and optimizer warranties cover the part but labor coverage varies, so ask who pays to send a technician onto the roof.
One failed microinverter costs only that panel's output, so it is not an emergency. But replace it before the roof is reworked or more units fail.
Could new shade from tree growth be the problem?
Yes, and it is one of the most common causes of slow declines. Trees grow every year. Signs of new shade:
- Production is lower mostly in the morning or afternoon, not at noon.
- The drop is worse in winter, when the sun is lower in the southern sky and shadows are longer.
- Panel-level data shows the same panels lagging at the same time each day.
- A neighbor added a second story, a large tree, or a new structure.
PVWatts' default losses include about 3 percent for shading from distant objects. Nearby trees can cost far more. Trimming often brings production back. See roof orientation, shade and trees.
Could dirt, pollen or heat explain the drop?
- Dirt and pollen: PVWatts assumes 2 percent soiling loss by default. Dry spells in West Texas, spring pollen in Florida, and bird droppings can do more. Test with a cleaning or after a heavy rain on a clear day. See maintenance and cleaning.
- Heat: panels lose a fraction of a percent per degree Celsius above 25°C. July afternoons in Texas or Florida always show lower peak power than April. That is expected. See solar heat performance.
- Florida's rainy season: June through September production is typically lower than April and May in PVWatts estimates for Miami, Tampa, Orlando and Jacksonville.
What is clipping, and does it mean I am losing power?
Clipping happens when the panels could make more DC power than the inverter can convert to AC. The inverter caps output at its rating, so the production graph shows a flat top at midday. The PVWatts manual explains that arrays are often sized with a DC rating higher than the inverter's AC rating to capture more energy in the morning and evening, "despite possibly clipping output at peak sun hours," and it uses a default DC-to-AC ratio of 1.1 in Version 5.
Some clipping is normal design, not a defect. It is a concern only if:
- The flat top lasts many hours a day, suggesting the inverter is undersized compared to the design.
- The cap is far below the inverter's rating, which points to an export limit, heat derating, or a setting.
- The cap appeared suddenly after a firmware update or utility change.
Ask your installer what DC-to-AC ratio the design used and whether an export limit was set by the utility.
Why is my electric bill high even though solar is working?
This is the most common complaint, and often the system is fine. Solar cuts the energy you buy, but your bill also depends on how much you use, when you use it, fixed charges, and how your utility values exports.
- Usage went up. A hot summer, a new EV, a pool pump, more people at home, or an aging AC can raise use faster than solar offsets it.
- Fixed charges stay. The PUC of Texas consumer guide warns solar does not eliminate your bill, since you still use grid power at night and may owe monthly base charges. Florida's rule says net metering customers still pay the customer charge regardless of exports.
- Exports are worth less than imports on many Texas plans. The PUC guide says the buyback rate is part of your contract with your retail provider and is usually lower than the retail price you pay.
- Timing. Solar peaks at midday. If most of your use is in the evening, you export at midday and buy back at night.
- Credit timing. Florida credits roll forward and true up yearly, so a summer bill may look high even though spring credits were applied earlier.
- The system was oversized in the sales pitch. If the seller promised a "$0 bill" that physics and your rate plan cannot deliver, the problem is the promise, not the panels. Texas HB 1640 was filed after complaints about overselling home solar.
To separate the causes, you need three numbers for the same month: production (from the app), consumption (from the app if you have consumption monitoring, or calculated), and what the bill shows for imports and exports.
Consumption = production + imports - exports. If production matches the estimate but consumption rose, the system is working and your use changed.
How do I read my bill against my solar production in Texas?
Competitive areas (Houston, Dallas-Fort Worth and most of the state)
Your wires utility (CenterPoint, Oncor, AEP Texas or TNMP) reads the meter and sends data to your retail electric provider (REP), which bills you. Texas Utilities Code 39.916(j) says a solar owner in a competitive area sells surplus to the REP serving their load at a value they agree on. In practice:
- Your bill shows kWh delivered to you and, if your plan has a buyback, kWh you exported and the credit.
- If the bill shows no export credit at all, check whether your plan includes buyback and whether the meter was set up to record exports. Oncor says data on surplus energy reaches the REP in the first full billing cycle (30 to 60 days) after the meter is set.
- Use Smart Meter Texas, which gets the same meter data, to see your daily imports and exports.
If you switch REPs or plans, the buyback terms change. See Texas solar buyback plans.
Austin Energy
Austin Energy bills you for all the energy you consume at standard rates and credits 100 percent of your solar production at its Value of Solar rate, 12.89 cents per kWh for FY2027 to FY2029. Because it credits production directly, your Austin bill is one of the easiest places to check whether production is normal: compare the credited solar kWh to your app.
CPS Energy (San Antonio) and co-ops
City-owned utilities and electric cooperatives set their own solar billing rules. The PUC guide notes the PUCT does not regulate them. Ask your utility for a sample net metering bill explanation.
How do I read my bill against my solar production in Florida?
FPL, Duke Energy Florida and Tampa Electric (investor-owned)
Florida's Rule 25-6.065 sets the rules. The utility installs a meter that measures the difference between energy delivered to you and energy you send back. Excess in a month is credited to the next month, credits carry for up to 12 months, and unused credits are paid at the utility's as-available (COG-1) rate at year end. Tampa Electric describes its version as billing only for net usage, kWh delivered minus kWh received, with negative net usage banked for the next month and a basic service charge still owed.
So a Florida net metering bill should show kWh delivered, kWh received, net kWh, and any banked credit. Your app's production will be higher than "kWh received" because much of your solar is used in the home before it reaches the meter. Tampa Electric also notes that net metering does not work with its Energy Planner program; net meter customers must be on the standard residential rate.
JEA (Jacksonville)
JEA is not bound by the PSC rule's billing terms. Under its Distributed Generation Policy, energy you send to the grid is credited at JEA's fuel rate, and you pay standard rates for energy you buy. Credits above your bill build up through the calendar year and are paid at year end. Because exports earn less than imports, a JEA customer with high daytime exports and high evening use can see higher bills than a net metering customer with the same system.
OUC (Orlando)
OUC changed its rules in 2025 and 2026. Systems connected or approved on or before June 30, 2025 keep full retail credit through June 30, 2045. Later systems are credited at OUC's Community Solar Energy Rate for five years, then at a lower rate. Starting November 1, 2026, OUC retired its "solar bank" and now credits excess energy immediately to the account. If your OUC bill looks different this winter, that change may be why.
See Florida net metering and solar electric bill explained.
Was my system designed or sold wrong?
Sometimes low production is not a fault at all. The system was oversold. Signs:
- Production has matched a PVWatts estimate for your actual roof from day one, but falls far short of the seller's estimate.
- The estimate assumed a south-facing roof, but your panels face east, west or north.
- The estimate ignored trees that were already there.
- The seller promised you would "never pay an electric bill again."
This is common enough that it shaped Texas law. Texas Appleseed's 2024 report on Texas Attorney General complaint records found 45 percent of solar complaints cited false or misleading statements, and complaints to the AG and TDLR rose sharply from 2018 to 2023. In 2025 Texas passed SB 1036, creating Occupations Code ch. 1806, which prohibits false, misleading or deceptive statements in residential solar sales (Sec. 1806.201) and lets TDLR order a contract cancelled and amounts paid refunded after notice and hearing (Sec. 1806.207).
In Florida, consumer complaints about sales practices go to the Florida Department of Agriculture and Consumer Services or the Attorney General, and license complaints against contractors go to DBPR. Our solar complaints guide lists where to file.
How do I enforce a production guarantee?
Some contracts, especially leases and power purchase agreements, include a production guarantee: the company promises a certain number of kWh per year and pays you or credits you if the system falls short. Owned systems rarely have one; they have equipment warranties instead.
- Find the exact wording. Look for the guaranteed kWh, the measuring period (often annual or cumulative), what counts as an excused shortfall (weather, outages, shading you added), and how to claim.
- Gather data. Monthly production from the app, utility bills, any downtime records, photos of shade or damage, and your PVWatts run.
- Make a written claim by the method in the contract, keeping a copy and proof of sending.
- Escalate in writing if they do not respond in the time the contract gives.
- Use state agencies. In Texas, Bus. and Com. Code ch. 115 requires performance representations and warranties in writing and lease or PPA terms disclosed, including whether the agreement transfers to a buyer. TDLR handles retailer complaints for contracts signed on or after September 1, 2025; earlier contracts go to the Texas Attorney General's Consumer Protection Division. In Florida, use FDACS or the Attorney General for sales problems and DBPR for contractor license issues.
- Get legal advice for large disputes. This page is general information, not legal advice.
What if my installer will not respond or has gone out of business?
This happens often enough that the industry calls them orphaned systems. You still have options:
- Gather your paperwork: contract, permit numbers, equipment list with model and serial numbers, warranty documents, monitoring login, and interconnection agreement. Your city or county building department has the permit file, and your utility has the interconnection record.
- Go straight to the manufacturers. Panel, inverter, microinverter and battery warranties come from the makers, not the installer. Most accept claims through a licensed service company if the original installer is gone. Ask whether labor is covered.
- Hire a licensed service company. In Texas, a TDLR-licensed electrical contractor; in Florida, a licensed solar or electrical contractor. Ask whether they take service calls on systems they did not install, and get a written diagnosis before repairs.
- Recover monitoring. Ask the inverter maker to transfer the monitoring account to you as the system owner.
- Check the workmanship warranty for any third-party backing or insurance that survives the installer's closure.
- If you lease, the leasing company, not the installer, usually owns the system and must service it. Call them.
Our warranties guide covers orphaned-system claims, and removal, reinstall and repair covers finding service help.
When should I call an electrician instead of the installer?
- A breaker trips more than once.
- You see an arc fault, ground fault or isolation error.
- You smell burning, see scorch marks, or hear buzzing or crackling at the inverter, disconnect or panel.
- Storm damage to panels, conduit or wiring.
- Water got into the inverter, disconnect or battery area.
- The installer is unreachable and the system has been off for more than a few days.
For anything that looks like fire risk, such as smoke, flames or sparking, call 911 first. Tell responders you have solar; the rapid shutdown switch is usually near the meter.
How to choose a provider
- Check weather, the monitoring app, the inverter light, the solar breaker and the rapid shutdown switch.
- Reset a tripped breaker only once; if it trips again, call a licensed electrician.
- Run PVWatts for your exact roof and system size.
- Compare this month to the same month last year and to the estimate, using clear days for a cleaner check.
- Allow for weather swings of up to 30 to 40 percent in a single month and about 0.5 percent a year of aging.
- Check panel-level or string-level data for one low panel or string.
- Look from the ground for new shade, debris, droppings or storm damage.
- Reconnect monitoring if only the data stopped.
- Pull your bill and compare imports, exports and credits to the app; in Texas use Smart Meter Texas.
- Write down error codes with dates and photos.
- File warranty claims with the equipment makers if the installer is gone.
- Use TDLR or the Texas AG, or FDACS, the Florida AG and DBPR, for sales or contractor disputes.
Related residential solar installers guides
- What Do Solar Warranties Actually Cover? Panels, Inverters, Batteries, Workmanship and Roof Leaks
- String Inverters vs Microinverters vs Optimizers: Which Fits a Texas or Florida Home?
- Do Solar Panels Need Cleaning and Maintenance in Texas and Florida?
- Do Solar Panels Work Well in Texas and Florida Heat?
- Why Do I Still Have an Electric Bill With Solar, and How Do I Read It in Texas and Florida?
- How Do Texas Solar Buyback Plans Work Without Net Metering?
- How Does Net Metering Work in Florida? PSC Rule 25-6.065, Credits, True-Up and Tiers
- How to File a Solar Complaint in Texas or Florida: Who Handles What
Residential solar installers by state and city
Questions people ask
Why is my solar producing less than my installer promised?
Three common reasons: weather and normal variation, a real fault, or an estimate that was too optimistic. Run PVWatts for your actual roof direction, tilt and shade. If production matches PVWatts but misses the sales estimate, the estimate was likely high. Texas law requires performance promises in writing, and since September 2025 TDLR can act on false or misleading solar sales statements for contracts signed after that date.
How much should a 10 kW system produce in Texas or Florida?
For a south-facing, 20-degree roof with default losses, PVWatts estimates roughly 14,200 kWh a year in Houston, 15,000 in Dallas or San Antonio, 15,500 in Miami and 15,700 in Tampa. East or west roofs, shade, and steeper or flatter tilts change this. Monthly totals vary widely, so compare annual or same-month numbers.
Is it normal for production to drop every year?
A small yearly decline is normal. NREL's review found a median of 0.5 percent a year, and PVWatts adds a one-time 1.5 percent light-induced loss early on. Panel warranties guarantee a maximum degradation rate, often printed on the datasheet. A much larger drop, such as 10 percent in one year with normal weather, points to a fault, shade or soiling.
My inverter shows a ground fault. Can I reset it?
Do not keep resetting it. A ground fault means current may be leaking through damaged insulation or wet connectors, which is a shock and fire risk. The inverter shut down to protect you. Leave the system off and call a licensed electrician with solar experience: TDLR-licensed in Texas, or a licensed solar or electrical contractor in Florida. Note the code and when it appeared.
Why does my app show zero but my bill shows solar credits?
The monitoring link is probably broken while the system keeps producing. A new router, a changed Wi-Fi password, an unplugged gateway or an expired cellular connection are common causes. Check the inverter light on a sunny day and your meter's export readings, or Smart Meter Texas in competitive Texas areas. Then reconnect the gateway using the maker's setup steps.
Does a power outage damage solar panels?
Usually not. The inverter shuts off during an outage by design and restarts when the grid is stable. Surges or storm damage can trip breakers or damage electronics. If your system does not restart within a few hours of power returning, check breakers, the shutdown switch and inverter codes, and call for service if a fault persists.
Can my utility limit my solar production?
Utilities generally do not turn down a home system day to day, but some interconnection agreements set export limits or require certain inverter settings, and inverters reduce output on their own when grid voltage runs high. If your production graph shows a flat cap well below the inverter's rating, ask your installer and utility whether an export limit or voltage problem is the cause.
Who do I call if my leased system stops working?
Call the leasing or PPA company named on your contract, not the original sales company. In most leases and PPAs, the system owner is responsible for maintenance and repairs, and some contracts include a production guarantee. Keep records of downtime and your monthly production, because lost production may be owed back to you under the guarantee terms.
Sources
- NREL (now NLR): PVWatts Version 5 Manual (uncertainty, losses, clipping)
- NLR PVWatts v8 model output, Houston (other cities by latitude/longitude)
- NLR PVWatts v8 model output, Tampa
- Jordan and Kurtz, NREL: Photovoltaic Degradation Rates, An Analytical Review (2012)
- REC Alpha Pure panels installation manual (UL), Rev. 18, March 2026 (DC safety)
- Florida Administrative Code Rule 25-6.065
- Tampa Electric: Solar incentives and net metering
- Tampa Electric: Net metering and Energy Planner
- JEA: Distributed generation
- JEA: Distributed generation bill breakdown
- OUC: How to apply for your home solar
- Austin Energy: Value of Solar rate
- Oncor: Meter FAQs (Smart Meter Texas, estimated bills after outages)
- Oncor: Information for installers (meters, surplus data, UL 1741)
- Texas Utilities Code ch. 39 (Sec. 39.916)
- PUC of Texas: Solar Guide for Consumers (March 2026)
- Texas Business and Commerce Code ch. 115
- Texas Occupations Code ch. 1806 (Residential Solar Retailer Regulatory Act)
- TDLR: Residential solar retail sales now regulated by TDLR (Sept. 10, 2025)
- TDLR: Electricians program
- Texas HB 1640 (89th Legislature) bill analysis
- Texas Appleseed: Solar panel complaints report (Oct. 2024)
- FDACS: Home solicitation sales
- Florida Attorney General: Consumer protection
This guide was written by our editorial team from the public sources listed above. It is general information, not legal advice; confirm licensing and terms directly with any provider.